docs(rotator): name the Green Heron RT-21, which was already supported

The RT-21 speaks the Hy-Gain DCU-1 command set in its default protocol
setting, and internal/rotator/dcu1 has driven that since it landed —
AP1nnn/AM1 to point, AI1 to read back, over a COM port or over TCP.
Nothing was missing except a way to find it: "Green Heron" sat in a
parenthesis after "Hy-Gain DCU-1", which an operator scanning the list
for RT-21 does not see.

So the dropdown leads with the controller people actually own, and the
hint says the two things that decide whether it works: the RT-21's
protocol must be set to DCU-1 / Rotor-EZ (on GS-232 it belongs to the
GS-232 entry instead), and with the Ethernet option TCP reaches it
directly rather than through a serial-over-IP bridge, which is what the
hint used to imply was necessary.

The package doc now also records what is NOT here: the native Green
Heron protocol is a third command set, with 0.1° readback and a real
stop, and writing it from memory is exactly the mistake this repo warns
about for wire protocols.
This commit is contained in:
2026-09-10 18:58:04 +02:00
parent 72696a5c0c
commit 031fcbd543
5 changed files with 17 additions and 8 deletions
+1 -1
View File
@@ -17175,7 +17175,7 @@ var rotatorTypes = []RotatorTypeInfo{
{ID: "rotgenius", Label: "Rotator Genius (4O3A, native)", Network: true, DefaultPort: 9006},
{ID: "arco", Label: "GS-232 azimuth controller (microHAM ARCO, ERC)", Network: true, Serial: true, DefaultPort: 4001, DefaultBaud: 9600},
{ID: "erc", Label: "ERC-M by DF9GR (Yaesu G-5500 az/el)", Elevation: true, Network: true, Serial: true, DefaultPort: 4001, DefaultBaud: 19200},
{ID: "dcu1", Label: "Hy-Gain DCU-1 (RotorCard DXA, Rotor-EZ, Green Heron)", Network: true, Serial: true, DefaultPort: 4001, DefaultBaud: 4800},
{ID: "dcu1", Label: "Green Heron RT-21 / Hy-Gain DCU-1 (Rotor-EZ, RotorCard DXA)", Network: true, Serial: true, DefaultPort: 4001, DefaultBaud: 4800},
{ID: "spid", Label: "SPID / AlfaSpid (RAS, BIG-RAS, MD-01, MD-02)", Elevation: true, Serial: true, DefaultBaud: 600},
{ID: "easycomm", Label: "EasyComm II (SatPC32, Gpredict, K3NG…)", Elevation: true, Network: true, Serial: true, DefaultPort: 4533, DefaultBaud: 9600},
}