docs(rotator): name the Green Heron RT-21, which was already supported
The RT-21 speaks the Hy-Gain DCU-1 command set in its default protocol setting, and internal/rotator/dcu1 has driven that since it landed — AP1nnn/AM1 to point, AI1 to read back, over a COM port or over TCP. Nothing was missing except a way to find it: "Green Heron" sat in a parenthesis after "Hy-Gain DCU-1", which an operator scanning the list for RT-21 does not see. So the dropdown leads with the controller people actually own, and the hint says the two things that decide whether it works: the RT-21's protocol must be set to DCU-1 / Rotor-EZ (on GS-232 it belongs to the GS-232 entry instead), and with the Ethernet option TCP reaches it directly rather than through a serial-over-IP bridge, which is what the hint used to imply was necessary. The package doc now also records what is NOT here: the native Green Heron protocol is a third command set, with 0.1° readback and a real stop, and writing it from memory is exactly the mistake this repo warns about for wire protocols.