fix(elecraft): the K3 power meter converts to real watts
The operator measured the whole table: 10 W showed 83, 12 W showed 100, 13 W showed 8 — the bargraph is relative to a meter RANGE that flips at 12 W (0-12 QRP, 0-120 above). A bar percentage was never watts; with the PC setting choosing the range, it converts, and the console prints the watts beside the bar.
This commit is contained in:
@@ -1083,6 +1083,7 @@ export namespace cat {
|
||||
s_meter: number;
|
||||
s_meter_raw: number;
|
||||
power_meter: number;
|
||||
power_w: number;
|
||||
swr: number;
|
||||
swr_raw: number;
|
||||
rf_power: number;
|
||||
@@ -1120,6 +1121,7 @@ export namespace cat {
|
||||
this.s_meter = source["s_meter"];
|
||||
this.s_meter_raw = source["s_meter_raw"];
|
||||
this.power_meter = source["power_meter"];
|
||||
this.power_w = source["power_w"];
|
||||
this.swr = source["swr"];
|
||||
this.swr_raw = source["swr_raw"];
|
||||
this.rf_power = source["rf_power"];
|
||||
|
||||
Reference in New Issue
Block a user