fix(ultrabeam): accept an 11-byte status frame from older controllers
An older controller behind an RS232-to-Ethernet bridge returns the status frame without its trailing FreqMax byte (11 bytes, not 12). The packet checksum is still valid, so it's a real short frame, not a fragment. queryStatus now accepts >= 10 bytes and defaults the missing FreqMin/FreqMax rather than rejecting it as "too short", which reconnect-looped the link. Whether the byte LAYOUT is otherwise identical across controller versions still needs confirming from the protocol reference.
This commit is contained in:
@@ -509,7 +509,13 @@ func (c *Client) queryStatus() (*Status, error) {
|
||||
return nil, err
|
||||
}
|
||||
|
||||
if len(reply) < 12 {
|
||||
// An older controller — seen behind an RS232-to-Ethernet bridge — answers with
|
||||
// an 11-byte status frame: the standard one WITHOUT the trailing FreqMax byte.
|
||||
// The packet checksum was already verified, so a short-but-valid frame is real,
|
||||
// not a fragment. Accept it and default the missing tail fields instead of
|
||||
// reconnect-looping on "reply too short". reply[9]/[10] (MotorsMoving, FreqMin)
|
||||
// are the last we truly need, so 10 bytes is the floor.
|
||||
if len(reply) < 10 {
|
||||
return nil, fmt.Errorf("status reply too short: %d bytes", len(reply))
|
||||
}
|
||||
|
||||
@@ -522,8 +528,12 @@ func (c *Client) queryStatus() (*Status, error) {
|
||||
Direction: int(reply[6] & 0x0F),
|
||||
OffState: (reply[7] & 0x02) != 0,
|
||||
MotorsMoving: int(reply[9]),
|
||||
FreqMin: int(reply[10]),
|
||||
FreqMax: int(reply[11]),
|
||||
}
|
||||
if len(reply) > 10 {
|
||||
status.FreqMin = int(reply[10])
|
||||
}
|
||||
if len(reply) > 11 {
|
||||
status.FreqMax = int(reply[11])
|
||||
}
|
||||
|
||||
return status, nil
|
||||
|
||||
Reference in New Issue