fix: PGXL meters/auth/fan, TCI spots+click, PTT-over-CAT, CW <LOGQSO>
- PGXL: remote AUTH password; direct-link meter fallback (VITA-first) with 250 ms poll + peak-hold; fan mode uses bare "fanmode=" (was ignored). - TCI: spot colour sent as decimal ARGB (ExpertSDR dropped the hex string); spot click handled via CLICKED_ON_SPOT / RX_CLICKED_ON_SPOT to fill the entry. - FlexRadio: clicking an OpsLog spot on the panadapter now applies the mode too. - Filter presets: the trash icon deletes again (Radix pointer-down intercept). - PTT hotkey: keys over CAT when a backend is active (was hijacked by a stale Audio-tab RTS/DTR serial setting); AltGr keys allowed; presses logged. - CW macro <LOGQSO>: logs after the preceding CW is sent, not on the first letter.
This commit is contained in:
@@ -328,7 +328,10 @@ export function FlexPanel({ onCWSpeed, onReportRST }: { onCWSpeed?: (wpm: number
|
||||
// longer and the meters visibly trail the end of a transmission, which reads
|
||||
// as the app lagging rather than as a peak being held.
|
||||
const peak = useRef<Record<string, { v: number; t: number }>>({});
|
||||
const peakHold = (key: string, val: number, windowMs = 1000) => {
|
||||
const peakHold = (key: string, val: number, windowMs = 1000, live = true) => {
|
||||
// live=false throws the held value away at once (e.g. the carrier dropped),
|
||||
// so the meter falls immediately instead of coasting for the window.
|
||||
if (!live) { delete peak.current[key]; return val; }
|
||||
const now = Date.now();
|
||||
const p = peak.current[key];
|
||||
if (!p || val >= p.v || now - p.t > windowMs) { peak.current[key] = { v: val, t: now }; return val; }
|
||||
@@ -362,7 +365,7 @@ export function FlexPanel({ onCWSpeed, onReportRST }: { onCWSpeed?: (wpm: number
|
||||
let alive = true;
|
||||
const tick = async () => { try { const s: any = await GetPGXLStatus(); if (alive) setPg(s || { connected: false }); } catch {} };
|
||||
tick();
|
||||
const id = window.setInterval(tick, 2000);
|
||||
const id = window.setInterval(tick, 250); // match the amp's 250 ms poll so the card catches every envelope peak
|
||||
return () => { alive = false; window.clearInterval(id); };
|
||||
}, []);
|
||||
|
||||
@@ -1114,11 +1117,32 @@ export function FlexPanel({ onCWSpeed, onReportRST }: { onCWSpeed?: (wpm: number
|
||||
{/* Amplifier meters (FWD / ID / TEMP) — moved here from the Meters card
|
||||
and shown compact so they sit with the amp controls. */}
|
||||
{(() => {
|
||||
// Prefer the radio's VITA amp meters when they are flowing (local or
|
||||
// over a VPN) — fast, and the same values SmartSDR shows (incl. the
|
||||
// right temperature sensor). Fall back to the amp's OWN link only when
|
||||
// the radio isn't streaming them (a remote link without VITA).
|
||||
const meters = st.meters || [];
|
||||
const dbmToW = (d: number) => Math.pow(10, (d - 30) / 10);
|
||||
const amp = meters.filter((m) => (m.src || '').toUpperCase().includes('AMP')
|
||||
&& !/^(RL|DRV)$/i.test((m.name || '').trim()));
|
||||
if (off || amp.length === 0) return null;
|
||||
if (off || amp.length === 0) {
|
||||
const P = pg as any;
|
||||
if (!P.connected) return null;
|
||||
// Direct-link fallback: a 500 ms poll samples the SSB envelope at
|
||||
// random points, so peak-hold it (live=txing drops it the instant
|
||||
// PTT releases). The LDMOS pair can pull well past 25 A → 50 A scale.
|
||||
const txing = typeof st.transmitting === 'boolean' ? st.transmitting : /TRANSMIT/i.test(P.state || '');
|
||||
const w = txing ? Math.round(Number(P.fwd_w) || 0) : 0;
|
||||
const idA = txing ? Number(P.id) || 0 : 0;
|
||||
const temp = Number(P.temperature) || 0;
|
||||
return (
|
||||
<div className="grid grid-cols-2 sm:grid-cols-3 gap-2 mt-2 pt-2 border-t border-border/50">
|
||||
<MeterBar label={t('ampw.pwr')} value={peakHold('pgw', w, 2500, txing)} unit="W" lo={0} hi={2000} accent="#dc2626" />
|
||||
<MeterBar label={t('ampw.id')} value={peakHold('pgid', idA, 2500, txing)} unit="A" lo={0} hi={50} accent="#16a34a" />
|
||||
<MeterBar label={t('ampw.temp')} value={temp} unit="°C" lo={0} hi={80} accent="#ea580c" />
|
||||
</div>
|
||||
);
|
||||
}
|
||||
// Power comes from the radio's meter stream and nothing else. The
|
||||
// amplifier also reports a "peakfwd", and using it was a mistake
|
||||
// twice over: it is a latched maximum that is never reset, and it
|
||||
@@ -1133,14 +1157,13 @@ export function FlexPanel({ onCWSpeed, onReportRST }: { onCWSpeed?: (wpm: number
|
||||
}
|
||||
const acc = /temp|degc|degf/i.test(`${m.unit}${m.name}`) ? '#ea580c' : /volt/i.test(m.unit || '') ? '#2563eb' : '#16a34a';
|
||||
// Drain current (ID): the PGXL reports a full-scale far too small
|
||||
// for this meter (~3 A), so 1.5 A pinned the bar near half. The
|
||||
// value itself is fine — only the bar's range was wrong. Give it a
|
||||
// fixed 25 A scale (the PGXL's LDMOS pair tops out around 20 A), and
|
||||
// only override an unusable reported range, not a sane one.
|
||||
// for this meter, so it pinned the bar. Give it a fixed 50 A scale
|
||||
// (the LDMOS pair can pull ~45-50 A near full output), overriding an
|
||||
// unusable reported range but keeping a sane one.
|
||||
let lo = m.lo, hi = m.hi;
|
||||
if (/amp/i.test(m.unit || '') || /^ID$|current/i.test(m.name || '')) {
|
||||
lo = 0;
|
||||
hi = m.hi >= 25 ? m.hi : 25;
|
||||
hi = m.hi >= 50 ? m.hi : 50;
|
||||
}
|
||||
return <MeterBar key={m.id} label={m.name || `AMP ${m.id}`} value={peakHold(`amp${m.id}`, m.value)} unit={m.unit} lo={lo} hi={hi} accent={acc} />;
|
||||
})}
|
||||
|
||||
Reference in New Issue
Block a user