chore: release v0.20.7

This commit is contained in:
2026-07-21 18:26:34 +02:00
parent 828f99b8ac
commit 24a5a0480d
15 changed files with 909 additions and 183 deletions
+61 -4
View File
@@ -5,6 +5,7 @@ import {
FlexSetProcessor, FlexSetProcessorLevel, FlexSetMon, FlexSetMonLevel, FlexSetMic,
FlexMox, FlexAmpOperate,
GetPGXLStatus, PGXLSetFanMode, GetPGXLSettings, GetSPEStatus, SPESetOperate, SPESetPower, SPESetPowerLevel,
GetACOMStatus, ACOMSetOperate, ACOMSetPower,
FlexSetAGCMode, FlexSetAGCThreshold, FlexSetAudioLevel, FlexSetMute, FlexSetRXAntenna, FlexSetTXAntenna, FlexSetSplit, FlexSetActiveSlice, FlexSetTXSlice,
FlexSetRIT, FlexSetRITFreq, FlexSetXIT, FlexSetXITFreq,
FlexSetNB, FlexSetNBLevel, FlexSetNR, FlexSetNRLevel, FlexSetANF, FlexSetANFLevel,
@@ -352,7 +353,8 @@ export function FlexPanel({ onCWSpeed, onReportRST }: { onCWSpeed?: (wpm: number
const id = window.setInterval(load, 5000);
return () => { alive = false; window.clearInterval(id); };
}, []);
const isSPE = ampEnabled && ampType !== 'pgxl';
const isACOM = ampEnabled && ampType.startsWith('acom');
const isSPE = ampEnabled && !isACOM && ampType !== 'pgxl';
// SPE Expert live status (only polled when an SPE amp is configured).
const [spe, setSpe] = useState<any>({ connected: false });
useEffect(() => {
@@ -363,6 +365,16 @@ export function FlexPanel({ onCWSpeed, onReportRST }: { onCWSpeed?: (wpm: number
const id = window.setInterval(tick, 1500);
return () => { alive = false; window.clearInterval(id); };
}, [isSPE]);
// ACOM live status (only polled when an ACOM amp is configured).
const [acom, setAcom] = useState<any>({ connected: false });
useEffect(() => {
if (!isACOM) return;
let alive = true;
const tick = () => GetACOMStatus().then((s: any) => alive && setAcom(s || { connected: false })).catch(() => {});
tick();
const id = window.setInterval(tick, 1500);
return () => { alive = false; window.clearInterval(id); };
}, [isACOM]);
const change = (key: keyof FlexState, val: number | boolean | string, send: () => Promise<any>) => {
hold.current[key] = Date.now() + 900;
@@ -872,10 +884,55 @@ export function FlexPanel({ onCWSpeed, onReportRST }: { onCWSpeed?: (wpm: number
</Card>
)}
{/* ACOM amplifier (serial/TCP) — shown when it's the configured amp. Driven
by OpsLog's own ACOM link (the Flex doesn't report ACOM amps). */}
{isACOM && (
<Card icon={Flame} title={`${t('flxp.amplifier')} · ACOM${acom.model ? ' ' + acom.model : ''}`} accent="#ea580c">
<div className="flex items-center gap-3 flex-wrap">
<button type="button" disabled={!acom.connected}
onClick={() => ACOMSetOperate(!acom.operate).catch(() => {})}
className={cn('px-4 py-2 rounded-lg text-sm font-extrabold tracking-wide border-2 transition-all disabled:opacity-30',
acom.operate ? 'bg-warning text-warning-foreground border-warning shadow-[0_0_14px] shadow-warning/50' : 'bg-card text-warning border-warning hover:bg-warning-muted')}>
{acom.operate ? 'OPERATE' : 'STANDBY'}
</button>
{/* Power ON is a DTR/RTS pulse — serial only, and it works while the amp
is off (the port stays open), so gate on port_open not connected. */}
<div className="inline-flex rounded-lg overflow-hidden border-2 border-success/70">
<button type="button" disabled={!(acom.port_open && acom.transport === 'serial')}
onClick={() => ACOMSetPower(true).catch(() => {})}
title={acom.transport === 'serial' ? 'Power on (DTR/RTS pulse — needs the power-on pins wired)' : 'Power-on needs the serial DTR/RTS lines — not available over a network bridge'}
className="px-3 py-2 text-sm font-bold bg-card text-success hover:bg-success/15 disabled:opacity-30">ON</button>
<button type="button" disabled={!acom.connected}
onClick={() => ACOMSetPower(false).catch(() => {})}
className="px-3 py-2 text-sm font-bold bg-card text-danger border-l-2 border-success/70 hover:bg-danger/15 disabled:opacity-30">OFF</button>
</div>
<span className={cn('inline-flex items-center gap-1.5 text-sm', acom.connected ? 'text-muted-foreground' : 'text-danger')}>
<span className={cn('size-2 rounded-full', acom.connected ? 'bg-success' : 'bg-danger')} />
{acom.connected ? acom.state : t('flxp.acomOffline')}
</span>
{acom.connected && (
<span className="text-sm font-mono text-muted-foreground tabular-nums">
{acom.band ? `${acom.band} · ` : ''}{acom.fwd_w}W · SWR {Number(acom.swr ?? 0).toFixed(1)} · {acom.temp_c}°C · Fan {acom.fan}
</span>
)}
<div className="flex-1" />
{acom.err_text && (
<span className="px-2 py-1 rounded bg-danger-muted text-danger-muted-foreground text-xs font-bold"> {acom.err_text}</span>
)}
</div>
{acom.connected && (
<MeterBar label={t('flxp.outputPower')} value={Number(acom.fwd_w) || 0} unit="W"
lo={0} hi={Number(acom.max_w) || 800}
display={`${Number(acom.fwd_w) || 0} W`}
segColor={(f) => (f > 0.9 ? '#dc2626' : f > 0.75 ? '#f59e0b' : '#ea580c')} />
)}
</Card>
)}
{/* External amplifier (PowerGenius XL) — only when the Flex reports one AND
PowerGenius is the selected amp type. Running an SPE Expert hides this
Flex-reported card so the two amps don't both show. */}
{st.amp_available && !isSPE && (
PowerGenius is the selected amp type. Running an SPE Expert or ACOM hides
this Flex-reported card so two amps don't both show. */}
{st.amp_available && !isSPE && !isACOM && (
<Card icon={Flame} title={`${t('flxp.amplifier')}${st.amp_model ? ' · ' + st.amp_model : ''}`} accent="#ea580c">
<div className="flex items-center gap-3">
<button type="button" disabled={off}