feat(kpa): the band-follow is asked for, not assumed

Telling somebody's amplifier where to be is a write to their station, and
it now has a switch — the SAME switch an Acom uses. 'Keep the amplifier on
the radio's band' is one idea to an operator; that it needs a second
serial port and a rig emulator on one amplifier and a single ^BN on
another is our business, not a reason for two checkboxes.

On by default for a KPA, because an amplifier left on the wrong band is
the worse outcome of the two, and the operator who has wired it straight
to the radio turns it off once. The hint says exactly that case, since it
is the only one where a second voice telling the amplifier where to be is
unwelcome.
This commit is contained in:
2026-08-26 18:07:35 +02:00
parent de95a437bb
commit 3013a2ba08
3 changed files with 21 additions and 3 deletions
+6 -1
View File
@@ -18285,7 +18285,12 @@ func (a *App) feedAmpBandFollow(s cat.RigState) {
// neither a second serial port nor a pretend rig. Sent from a goroutine
// because this runs on the CAT state-change path, and nothing about the
// rig should wait on an amplifier's link.
if inst.kpa != nil && s.Band != "" {
// Asked for, like every other write to somebody's station. The option is
// the same one an Acom uses — "keep the amplifier on the radio's band" is
// one idea to an operator, whatever it takes underneath — and it is off
// for the operator who has wired the amplifier straight to the rig and
// does not want a second voice telling it where to be.
if inst.kpa != nil && inst.cfg.FreqOut && s.Band != "" {
k, band := inst.kpa, s.Band
go func() { _ = k.SetBand(band) }()
}
+13
View File
@@ -4177,6 +4177,7 @@ function SettingsModalImpl({ onClose, onSaved, initialSection, onMainPaneChanged
// could never connect.
const applyType = (i: number, v: string) => patchAmp(i, {
type: v,
freq_out: v.startsWith('kpa') ? true : amps[i].freq_out,
transport: v === 'pgxl' ? 'tcp' : v === 'kpa500' ? 'serial' : amps[i].transport,
baud: v.startsWith('acom') ? 9600 : v.startsWith('spe') ? 115200 : v.startsWith('kpa') ? 38400 : amps[i].baud,
port: v === 'kpa1500' ? 1500 : amps[i].port,
@@ -4323,6 +4324,18 @@ function SettingsModalImpl({ onClose, onSaved, initialSection, onMainPaneChanged
Offering a second serial port and a transceiver emulator for
that would be a workaround for a problem this amplifier does
not have. */}
{isKPA && (
<div className="border-t border-border/60 pt-3 space-y-1">
<label className="flex items-center gap-2 text-sm cursor-pointer">
<Checkbox
checked={!!amp.freq_out}
onCheckedChange={(c) => patchAmp(i, { freq_out: !!c })}
/>
{t('amp.kpaBandFollow')}
</label>
<p className="text-[11px] text-muted-foreground">{t('amp.kpaBandFollowHint')}</p>
</div>
)}
{!isPGXL && !isKPA && (
<div className="border-t border-border/60 pt-3 space-y-3">
<label className="flex items-center gap-2 text-sm cursor-pointer">
+2 -2
View File
@@ -230,7 +230,7 @@ const en: Dict = {
'gen.showBeam': 'Show the antenna beam heading on the Main map',
'gen.startEqEnd': 'QSO start time = end time', 'gen.startEqEndHint': '(matches LoTW when you call a while)',
'gen.showQsoRate': 'Show QSO rate in the header', 'gen.showQsoRateHint': '(QSOs/hour, projected from the last 10 / 60 min)',
'gen.lookupOnBlur': 'Look up the callsign only after leaving the field', 'gen.lookupOnBlurHint': '(not while typing)', 'amp.hint': 'Configure one or several amplifiers — each panel card has a dropdown to pick which one it shows.', 'amp.linked': 'Amplifiers commanded together', 'amp.linkedHint': 'Tick the ones sharing a combiner: ON, OFF and OPERATE will act on all of them at once, since one left in STANDBY would feed power to a single input. Any amplifier left unticked keeps its own buttons. Each keeps its own meters.', 'amp.linkedSaveFirst': 'Save first — an amplifier needs an id before it can join a group.', 'amp.none': 'No amplifier configured yet.', 'amp.namePh': 'Name (e.g. SPE left)', 'amp.remove': 'Remove this amplifier', 'amp.add': 'Add amplifier', 'amp.password': 'Remote code', 'amp.passwordPh': 'blank on LAN', 'amp.passwordHint': 'PowerGenius XL only: needed when reaching the amp remotely — it then announces "AUTH" and rejects every command ("Unauthorized") until you log in. Leave blank on the local network.', 'amp.freqOut': 'Send the frequency to the amplifier (band follow)', 'amp.freqPort': 'CAT/AUX COM port', 'amp.freqBroadcast': 'Also send unprompted', 'amp.freqPollOnly': 'No — answer the amplifier only', 'amp.freqEvery': 'Yes, every {ms} ms', 'amp.freqHint': 'OpsLog pretends to be a transceiver on this second port, in Kenwood format: set the amplifier to that command set (set 5 on an Acom) at the same baud rate, and put it in OPERATE — in standby it acknowledges but does not switch band. An amplifier that POLLS (Acom) needs nothing more; one that only LISTENS to the CAT line of the radio hears nothing unless you also turn on the unprompted send.',
'gen.lookupOnBlur': 'Look up the callsign only after leaving the field', 'gen.lookupOnBlurHint': '(not while typing)', 'amp.hint': 'Configure one or several amplifiers — each panel card has a dropdown to pick which one it shows.', 'amp.linked': 'Amplifiers commanded together', 'amp.linkedHint': 'Tick the ones sharing a combiner: ON, OFF and OPERATE will act on all of them at once, since one left in STANDBY would feed power to a single input. Any amplifier left unticked keeps its own buttons. Each keeps its own meters.', 'amp.linkedSaveFirst': 'Save first — an amplifier needs an id before it can join a group.', 'amp.none': 'No amplifier configured yet.', 'amp.namePh': 'Name (e.g. SPE left)', 'amp.remove': 'Remove this amplifier', 'amp.add': 'Add amplifier', 'amp.password': 'Remote code', 'amp.passwordPh': 'blank on LAN', 'amp.passwordHint': 'PowerGenius XL only: needed when reaching the amp remotely — it then announces "AUTH" and rejects every command ("Unauthorized") until you log in. Leave blank on the local network.', 'amp.kpaBandFollow': 'Keep the amplifier on the radios band', 'amp.kpaBandFollowHint': 'Sends the band number when it changes, on the link already open — no second serial port. Turn it off if the amplifier is wired straight to the radio and takes its band from there.', 'amp.freqOut': 'Send the frequency to the amplifier (band follow)', 'amp.freqPort': 'CAT/AUX COM port', 'amp.freqBroadcast': 'Also send unprompted', 'amp.freqPollOnly': 'No — answer the amplifier only', 'amp.freqEvery': 'Yes, every {ms} ms', 'amp.freqHint': 'OpsLog pretends to be a transceiver on this second port, in Kenwood format: set the amplifier to that command set (set 5 on an Acom) at the same baud rate, and put it in OPERATE — in standby it acknowledges but does not switch band. An amplifier that POLLS (Acom) needs nothing more; one that only LISTENS to the CAT line of the radio hears nothing unless you also turn on the unprompted send.',
'gen.groupDigital': 'Group digital modes as one (DXCC-style)', 'gen.groupDigitalHint': '(matrix badges + cluster: FT8/FT4/RTTY… count as a single Digital mode; off = each digital mode is its own slot)',
// Password encryption
'gen.pwEnc': 'Password encryption',
@@ -716,7 +716,7 @@ const fr: Dict = {
'gen.showBeam': 'Afficher le cap de l\'antenne sur la carte principale',
'gen.startEqEnd': 'Heure de début du QSO = heure de fin', 'gen.startEqEndHint': '(correspond à LoTW quand tu appelles un moment)',
'gen.showQsoRate': 'Afficher le rythme QSO dans la barre du haut', 'gen.showQsoRateHint': '(QSO/heure, projeté sur les 10 / 60 dernières min)',
'gen.lookupOnBlur': 'Rechercher l\'indicatif seulement après avoir quitté le champ', 'gen.lookupOnBlurHint': '(pas pendant la saisie)', 'amp.hint': 'Configurez un ou plusieurs amplificateurs — chaque carte de panneau a une liste déroulante pour choisir lequel afficher.', 'amp.linked': 'Amplificateurs commandés ensemble', 'amp.linkedHint': "Coche ceux qui partagent un combiner : ON, OFF et OPERATE agiront sur tous à la fois, puisqu'un ampli resté en STANDBY n'alimenterait qu'une seule entrée. Un amplificateur non coché garde ses propres boutons. Chacun garde ses mesures.", 'amp.linkedSaveFirst': "Enregistre d'abord — un amplificateur a besoin d'un identifiant pour rejoindre un groupe.", 'amp.none': 'Aucun amplificateur configuré.', 'amp.namePh': 'Nom (p. ex. SPE gauche)', 'amp.remove': 'Supprimer cet amplificateur', 'amp.add': 'Ajouter un amplificateur', 'amp.password': 'Code distant', 'amp.passwordPh': 'vide en LAN', 'amp.passwordHint': "PowerGenius XL uniquement : nécessaire pour joindre l'ampli à distance — il annonce alors « AUTH » et refuse toute commande (« Unauthorized ») tant qu'on n'est pas identifié. Laisse vide sur le réseau local.", 'amp.freqOut': "Envoyer la fréquence à l'amplificateur (suivi de bande)", 'amp.freqPort': 'Port COM CAT/AUX', 'amp.freqBroadcast': 'Envoyer aussi sans être interrogé', 'amp.freqPollOnly': "Non — répondre seulement à l'amplificateur", 'amp.freqEvery': 'Oui, toutes les {ms} ms', 'amp.freqHint': "OpsLog se fait passer pour un transceiver sur ce second port, au format Kenwood : réglez l'amplificateur sur ce jeu de commandes (le jeu 5 sur un Acom) à la même vitesse, et mettez-le en OPERATE — en veille il acquitte mais ne change pas de bande. Un amplificateur qui INTERROGE (Acom) n'a besoin de rien de plus ; un amplificateur qui se contente d'ÉCOUTER la liaison CAT de la radio n'entendra rien tant que l'envoi spontané n'est pas activé.",
'gen.lookupOnBlur': 'Rechercher l\'indicatif seulement après avoir quitté le champ', 'gen.lookupOnBlurHint': '(pas pendant la saisie)', 'amp.hint': 'Configurez un ou plusieurs amplificateurs — chaque carte de panneau a une liste déroulante pour choisir lequel afficher.', 'amp.linked': 'Amplificateurs commandés ensemble', 'amp.linkedHint': "Coche ceux qui partagent un combiner : ON, OFF et OPERATE agiront sur tous à la fois, puisqu'un ampli resté en STANDBY n'alimenterait qu'une seule entrée. Un amplificateur non coché garde ses propres boutons. Chacun garde ses mesures.", 'amp.linkedSaveFirst': "Enregistre d'abord — un amplificateur a besoin d'un identifiant pour rejoindre un groupe.", 'amp.none': 'Aucun amplificateur configuré.', 'amp.namePh': 'Nom (p. ex. SPE gauche)', 'amp.remove': 'Supprimer cet amplificateur', 'amp.add': 'Ajouter un amplificateur', 'amp.password': 'Code distant', 'amp.passwordPh': 'vide en LAN', 'amp.passwordHint': "PowerGenius XL uniquement : nécessaire pour joindre l'ampli à distance — il annonce alors « AUTH » et refuse toute commande (« Unauthorized ») tant qu'on n'est pas identifié. Laisse vide sur le réseau local.", 'amp.kpaBandFollow': "Garder l'amplificateur sur la bande de la radio", 'amp.kpaBandFollowHint': "Envoie le numéro de bande quand elle change, sur la liaison déjà ouverte — pas de second port série. À désactiver si l'amplificateur est câblé directement à la radio et prend sa bande de là.", 'amp.freqOut': "Envoyer la fréquence à l'amplificateur (suivi de bande)", 'amp.freqPort': 'Port COM CAT/AUX', 'amp.freqBroadcast': 'Envoyer aussi sans être interrogé', 'amp.freqPollOnly': "Non — répondre seulement à l'amplificateur", 'amp.freqEvery': 'Oui, toutes les {ms} ms', 'amp.freqHint': "OpsLog se fait passer pour un transceiver sur ce second port, au format Kenwood : réglez l'amplificateur sur ce jeu de commandes (le jeu 5 sur un Acom) à la même vitesse, et mettez-le en OPERATE — en veille il acquitte mais ne change pas de bande. Un amplificateur qui INTERROGE (Acom) n'a besoin de rien de plus ; un amplificateur qui se contente d'ÉCOUTER la liaison CAT de la radio n'entendra rien tant que l'envoi spontané n'est pas activé.",
'gen.groupDigital': 'Regrouper les modes digitaux en un seul (style DXCC)', 'gen.groupDigitalHint': '(badges de la matrice + cluster : FT8/FT4/RTTY… comptent comme un seul mode Digital ; décoché = chaque mode digital est un slot distinct)',
// Chiffrement des mots de passe
'gen.pwEnc': 'Chiffrement des mots de passe',