feat: Kenwood CAT over a network serial bridge
The same ASCII stream over a socket instead of a wire: ser2net, an
Ethernet-serial adapter, a Raspberry Pi at the radio. One TCP transport
presented as a serial port, so the backend keeps a single code path.
Explicitly NOT the radio's own RJ45. A TS-890 or TS-990 speaks Kenwood's
KNS/ARCP there — session, authentication, a different protocol — and that needs
one of those radios in hand to write honestly. The setting's help text says so,
because an operator who plugs in their TS-890's Ethernet port and types its
address deserves to learn that from the interface rather than from silence.
Two details that decide whether this is usable or maddening:
- A read deadline expiring is reported as "no data yet", not as an error. It
is exactly what a serial read timeout means to the caller; as an error it
would make ask() abandon a rig that is merely thinking.
- The log line names what was connected to. "connected on @ 0 baud" after a
network connect sends someone hunting a serial fault that does not exist.
The host wins over the COM port when both are filled: it is the more deliberate
setting, and silently preferring the wire leaves someone staring at an address
they typed and a radio that never answers.
This commit is contained in:
@@ -1095,7 +1095,7 @@ export function SettingsModal({ onClose, onSaved, initialSection, onMainPaneChan
|
||||
const [modeDraft, setModeDraft] = useState('');
|
||||
const [catCfg, setCatCfg] = useState<CATSettings>({
|
||||
enabled: false, backend: 'omnirig', omnirig_rig: 1, omnirig_vfo: '', flex_host: '', flex_port: 4992, flex_spots: false, flex_decode_spots: false, flex_decode_secs: 120,
|
||||
yaesu_port: '', yaesu_baud: 38400, kenwood_port: '', kenwood_baud: 9600, xiegu_port: '', xiegu_baud: 19200, xiegu_addr: 0x70,
|
||||
yaesu_port: '', yaesu_baud: 38400, kenwood_port: '', kenwood_baud: 9600, kenwood_host: '', xiegu_port: '', xiegu_baud: 19200, xiegu_addr: 0x70,
|
||||
icom_port: '', icom_baud: 115200, icom_addr: 0x98, icom_net_host: '', icom_net_user: '', icom_net_pass: '', icom_net_audio: false,
|
||||
tci_host: '', tci_port: 40001, tci_spots: false, poll_ms: 250, delay_ms: 0,
|
||||
digital_default: 'FT8', share_enabled: false, share_port: 4532,
|
||||
@@ -2563,6 +2563,15 @@ export function SettingsModal({ onClose, onSaved, initialSection, onMainPaneChan
|
||||
</Select>
|
||||
<span className="text-xs text-muted-foreground">{t('cat.kenwoodBaudHint')}</span>
|
||||
</div>
|
||||
<div className="space-y-1">
|
||||
<Label>{t('cat.kenwoodHost')}</Label>
|
||||
<Input
|
||||
value={catCfg.kenwood_host || ''}
|
||||
placeholder="192.168.1.50:4532"
|
||||
onChange={(e) => setCatCfg((s) => ({ ...s, kenwood_host: e.target.value }))}
|
||||
/>
|
||||
<span className="text-xs text-muted-foreground">{t('cat.kenwoodHostHint')}</span>
|
||||
</div>
|
||||
</>
|
||||
)}
|
||||
{catCfg.backend === 'icom' && (
|
||||
|
||||
Reference in New Issue