feat(cat): make the DTR/RTS lowering a setting
Both defaults break someone. 0.22.7 lowered the lines on Yaesu and Kenwood and silenced a TS-990 whose interface needs RTS raised to transmit; 0.22.8 stopped lowering them and an FT8 station reported its output power wandering, cured by closing OpsLog — Windows raises both on open and the interface reads one as PTT. So it is now a checkbox on those two backends, off by default: that is how they behaved before any of this. Xiegu keeps lowering them unconditionally (its own report, its own explicit keying setting), and the CI-V backend keeps the behaviour it has always had.
This commit is contained in:
@@ -1924,6 +1924,7 @@ export namespace main {
|
||||
kenwood_host: string;
|
||||
kenwood_port: string;
|
||||
kenwood_baud: number;
|
||||
lower_lines: boolean;
|
||||
icom_port: string;
|
||||
icom_baud: number;
|
||||
icom_addr: number;
|
||||
@@ -1964,6 +1965,7 @@ export namespace main {
|
||||
this.kenwood_host = source["kenwood_host"];
|
||||
this.kenwood_port = source["kenwood_port"];
|
||||
this.kenwood_baud = source["kenwood_baud"];
|
||||
this.lower_lines = source["lower_lines"];
|
||||
this.icom_port = source["icom_port"];
|
||||
this.icom_baud = source["icom_baud"];
|
||||
this.icom_addr = source["icom_addr"];
|
||||
|
||||
Reference in New Issue