feat: generalize Settings 'Power Genius' into 'Amplifier' (type + serial/IP transport) for SPE Expert

Renames the Hardware section to Amplifier and adds an amplifier-type selector
(4O3A PowerGenius XL, SPE Expert 1.3K-FA / 1.5K-FA / 2K-FA) plus a transport
choice for the SPE amps: USB (serial COM + baud) or Network (RS232-to-Ethernet
IP:port). PGXLSettings gains Type/Transport/ComPort/Baud (keys keep the pgxl.*
prefix for back-compat). PowerGenius still drives over TCP; SPE settings are
stored but control is not wired yet (needs the SPE serial protocol).
This commit is contained in:
2026-07-20 17:44:56 +02:00
parent def59da748
commit 666b933114
4 changed files with 147 additions and 40 deletions
+78 -24
View File
@@ -276,7 +276,7 @@ const SECTION_LABELS: Partial<Record<SectionId, string>> = {
winkeyer: 'CW Keyer',
antenna: 'Ultrabeam / Steppir',
antgenius: 'Antenna Genius',
pgxl: 'Power Genius',
pgxl: 'Amplifier',
flex: 'FlexRadio',
relayauto: 'Relay auto-control',
audio: 'Audio devices',
@@ -1013,8 +1013,9 @@ export function SettingsModal({ onClose, onSaved, initialSection, onMainPaneChan
// Antenna Genius (4O3A) switch settings — TCP port is fixed at 9007.
const [antgenius, setAntgenius] = useState<{ enabled: boolean; host: string; password: string }>({ enabled: false, host: '', password: '' });
// PowerGenius XL (4O3A) amp fan-control settings.
const [pgxl, setPgxl] = useState<{ enabled: boolean; host: string; port: number }>({ enabled: false, host: '', port: 9008 });
// Amplifier control settings (PowerGenius XL over TCP; SPE Expert over serial/IP).
const [pgxl, setPgxl] = useState<{ enabled: boolean; type: string; transport: string; host: string; port: number; com_port: string; baud: number }>(
{ enabled: false, type: 'pgxl', transport: 'tcp', host: '', port: 9008, com_port: '', baud: 115200 });
// WinKeyer CW keyer settings + macro editor.
type WKMac = { label: string; text: string };
@@ -2645,36 +2646,89 @@ export function SettingsModal({ onClose, onSaved, initialSection, onMainPaneChan
}
function PGXLPanelSettings() {
const isPGXL = pgxl.type === 'pgxl';
const isSerial = pgxl.transport === 'serial';
return (
<>
<SectionHeader
title="Power Genius XL"
/>
<SectionHeader title="Amplifier" />
<div className="space-y-4 max-w-xl">
<label className="flex items-center gap-2 text-sm cursor-pointer">
<Checkbox checked={pgxl.enabled} onCheckedChange={(c) => setPgxl((s) => ({ ...s, enabled: !!c }))} />
Enable PowerGenius fan control
Enable amplifier control
</label>
<div className="grid grid-cols-3 gap-3">
<div className="space-y-1 col-span-2">
<Label>Host / IP</Label>
<Input
value={pgxl.host ?? ''}
onChange={(e) => setPgxl((s) => ({ ...s, host: e.target.value }))}
placeholder="192.168.1.70"
className="font-mono"
/>
</div>
<div className="grid grid-cols-2 gap-3">
<div className="space-y-1">
<Label>TCP port</Label>
<Input
type="number" min={1} max={65535}
value={pgxl.port}
onChange={(e) => setPgxl((s) => ({ ...s, port: parseInt(e.target.value) || 9008 }))}
className="font-mono"
/>
<Label>Amplifier</Label>
<Select value={pgxl.type} onValueChange={(v) => setPgxl((s) => ({ ...s, type: v, transport: v === 'pgxl' ? 'tcp' : s.transport }))}>
<SelectTrigger className="h-9"><SelectValue /></SelectTrigger>
<SelectContent>
<SelectItem value="pgxl">4O3A PowerGenius XL</SelectItem>
<SelectItem value="spe13">SPE Expert 1.3K-FA</SelectItem>
<SelectItem value="spe15">SPE Expert 1.5K-FA</SelectItem>
<SelectItem value="spe2k">SPE Expert 2K-FA</SelectItem>
</SelectContent>
</Select>
</div>
{/* PowerGenius is TCP-only; SPE amps connect over USB serial or an
RS232-to-Ethernet bridge, so they offer both. */}
{!isPGXL && (
<div className="space-y-1">
<Label>Connection</Label>
<Select value={pgxl.transport} onValueChange={(v) => setPgxl((s) => ({ ...s, transport: v }))}>
<SelectTrigger className="h-9"><SelectValue /></SelectTrigger>
<SelectContent>
<SelectItem value="serial">USB (serial COM)</SelectItem>
<SelectItem value="tcp">Network (RS232-to-Ethernet)</SelectItem>
</SelectContent>
</Select>
</div>
)}
</div>
{isSerial ? (
<div className="grid grid-cols-3 gap-3">
<div className="space-y-1 col-span-2">
<Label>COM port</Label>
<div className="flex items-center gap-2">
<Select value={pgxl.com_port || '_'} onValueChange={(v) => setPgxl((s) => ({ ...s, com_port: v === '_' ? '' : v }))}>
<SelectTrigger className="h-9 flex-1"><SelectValue placeholder="— COM —" /></SelectTrigger>
<SelectContent>
{wkPorts.length === 0 && <SelectItem value="_" disabled>No ports found</SelectItem>}
{wkPorts.map((p) => <SelectItem key={p} value={p}>{p}</SelectItem>)}
</SelectContent>
</Select>
<Button size="sm" variant="outline" className="h-9" onClick={() => ListSerialPorts().then((p) => setWkPorts((p ?? []) as string[])).catch(() => {})}>
<ArrowDown className="size-3.5 rotate-90" />
</Button>
</div>
</div>
<div className="space-y-1">
<Label>Baud</Label>
<Input type="number" min={1200} value={pgxl.baud}
onChange={(e) => setPgxl((s) => ({ ...s, baud: parseInt(e.target.value) || 115200 }))} className="font-mono" />
</div>
</div>
) : (
<div className="grid grid-cols-3 gap-3">
<div className="space-y-1 col-span-2">
<Label>Host / IP</Label>
<Input value={pgxl.host ?? ''} onChange={(e) => setPgxl((s) => ({ ...s, host: e.target.value }))}
placeholder="192.168.1.70" className="font-mono" />
</div>
<div className="space-y-1">
<Label>TCP port</Label>
<Input type="number" min={1} max={65535} value={pgxl.port}
onChange={(e) => setPgxl((s) => ({ ...s, port: parseInt(e.target.value) || 9008 }))} className="font-mono" />
</div>
</div>
)}
{!isPGXL && (
<p className="text-xs text-warning">
SPE Expert control is not wired up yet these settings are saved, but OpsLog can't command the amp until its serial protocol is implemented.
</p>
)}
</div>
</>
);