feat: CI-V byte trace, for a fault the command table cannot explain

Reported on an IC-9100: the MOX button does not transmit, it sets split. The
source sends the PTT command (0x1C 0x00) and nowhere sends the split one (0x0F),
so the discrepancy is between what OpsLog sends and what the rig acts on — and
that link has already been shown, in the same operator's log, to lose frame sync.

Rather than guess from the command table, this adds what settled the WinKeyer
bug in one line: the actual bytes. Settings → CAT → Log the CI-V protocol writes
every frame in both directions as hex. RX is traced BEFORE framing, since the
bytes as they arrived are what reveals a lost boundary — a decoded view would
hide exactly the fault being hunted.

Session-only, like the keyer trace: it is a diagnostic, and a log full of hex
helps nobody who forgot it was on.

I am not claiming a cause yet. The last time I inferred one from a protocol
document rather than from evidence, I inverted a digit and broke the case that
worked.
This commit is contained in:
2026-07-30 14:30:05 +02:00
parent ef84b04c99
commit 75c02ea2a0
8 changed files with 76 additions and 5 deletions
+4 -2
View File
@@ -8,7 +8,8 @@
"Yaesu: the mode follows the VFO you are on. A spot clicked while working the SUB receiver tuned the sub VFO but set the mode on MAIN, leaving the VFO in use on its old mode; the console read main mode too.",
"Rotator control now covers any GS-232A controller, ERC (Easy Rotor Control) included: the serial speed is selectable and the entry is named after the protocol rather than one device. Set the ERC to GS-232 emulation, not Hy-Gain DCU-1.",
"Native Kenwood CAT: a sixth backend talks straight to a TS-590, TS-890, TS-990 or TS-2000 over its serial port — frequency, mode, VFO, split and PTT — with no OmniRig in between. Elecraft K3/K4 speak the same dialect. Pick \"Kenwood (native)\" in Settings → CAT.",
"Icom and Xiegu: a CI-V frame read at the wrong offset no longer turns into a frequency. Values such as 16445550000 Hz appeared in the status bar while the rig sat on 145.550 MHz — the decoder treated non-decimal bytes as digits. Such frames are now refused and the last good reading stands."
"Icom and Xiegu: a CI-V frame read at the wrong offset no longer turns into a frequency. Values such as 16445550000 Hz appeared in the status bar while the rig sat on 145.550 MHz — the decoder treated non-decimal bytes as digits. Such frames are now refused and the last good reading stands.",
"Settings → CAT can log the CI-V protocol: every frame to and from an Icom or Xiegu, as hex. For reporting a radio that answers oddly — a button that does the wrong thing, a frequency that jumps — where a description alone leaves the cause to guesswork."
],
"fr": [
"Les entrées de réglages Antenna Genius et Tuner Genius portent une petite marque 4O3A : les panneaux pilotant ce matériel se repèrent d'un coup d'œil dans le menu.",
@@ -16,7 +17,8 @@
"Yaesu : le mode suit le VFO utilisé. Un spot cliqué en travaillant sur le récepteur SUB accordait bien le VFO secondaire mais réglait le mode sur le MAIN, laissant le VFO en service sur son ancien mode ; la console lisait également le mode du principal.",
"Le contrôle de rotator couvre désormais tout contrôleur GS-232A, ERC (Easy Rotor Control) compris : la vitesse du port série est sélectionnable et l'entrée porte le nom du protocole plutôt que celui d'un seul appareil. Réglez l'ERC sur l'émulation GS-232, pas Hy-Gain DCU-1.",
"CAT Kenwood natif : un sixième backend parle directement à un TS-590, TS-890, TS-990 ou TS-2000 par son port série — fréquence, mode, VFO, split et PTT — sans OmniRig. Les Elecraft K3/K4 parlent le même dialecte. À choisir sous « Kenwood (natif) » dans Réglages → CAT.",
"Icom et Xiegu : une trame CI-V lue au mauvais décalage ne se transforme plus en fréquence. Des valeurs comme 16445550000 Hz apparaissaient dans la barre d'état alors que la radio était sur 145,550 MHz — le décodeur prenait des octets non décimaux pour des chiffres. Ces trames sont désormais refusées et la dernière lecture valable est conservée."
"Icom et Xiegu : une trame CI-V lue au mauvais décalage ne se transforme plus en fréquence. Des valeurs comme 16445550000 Hz apparaissaient dans la barre d'état alors que la radio était sur 145,550 MHz — le décodeur prenait des octets non décimaux pour des chiffres. Ces trames sont désormais refusées et la dernière lecture valable est conservée.",
"Réglages → CAT permet de journaliser le protocole CI-V : chaque trame échangée avec un Icom ou un Xiegu, en hexadécimal. Pour signaler une radio qui répond de travers — un bouton qui fait autre chose, une fréquence qui saute — là où une description seule laisse la cause à la devinette."
]
},
{