fix(icom): the client pings too — the dropouts' likely root cause
wfview sends a ping (0x07, 0x15 bytes, its own seq and a monotonic timestamp) every 500 ms on every stream, and so does RS-BA1. OpsLog only ever REPLIED to the rig's pings — and the loaner IC-7760 stopped serving CI-V data about a minute into nearly every session while the transport stayed alive: the rig had concluded nobody was listening. Scope, TX audio and idle numbering were each eliminated in turn before wfview's source settled it. Pings now go out on control, CI-V and audio alike.
This commit is contained in:
+4
-2
@@ -38,7 +38,8 @@
|
||||
"Cluster: spots on the standard FT8/FT4 frequencies of every band now read FT8/FT4 when the comment names no mode — 30 m, 60 m, 80 m FT4, 17 m FT4 and 12 m were falling into the generic DATA bucket.",
|
||||
"OmniRig (Yaesu): with split engaged, tuning to a spot moves BOTH VFOs — on an FT-2000 the write landed on the TX VFO only, so the transmitter QSYed and the receiver stayed behind.",
|
||||
"Icom network: Wake-on-LAN — a rig switched fully off (LAN server down) is woken with a magic packet to its remembered MAC whenever a session is wanted, so the console and its ON button come back without a walk to the shack.",
|
||||
"Worked before: a slow lookup can no longer overwrite a newer one — typing a second callsign quickly could leave the previous call’s QSOs displayed under the new call’s name."
|
||||
"Worked before: a slow lookup can no longer overwrite a newer one — typing a second callsign quickly could leave the previous call’s QSOs displayed under the new call’s name.",
|
||||
"Icom network: OpsLog now sends its own pings every 500 ms on all three streams, as RS-BA1 and wfview do — a client that only ever replied was judged absent by the rig, which stopped serving CI-V data about a minute into every session: the recurring sound/CAT dropouts."
|
||||
],
|
||||
"fr": [
|
||||
"Console Elecraft : le S-mètre est calibré sur un vrai K3 — S9 et les +dB correspondent désormais à l’affichage de la radio (il lisait environ deux points S trop bas).",
|
||||
@@ -76,7 +77,8 @@
|
||||
"Cluster : les spots sur les fréquences standard FT8/FT4 de chaque bande lisent désormais FT8/FT4 quand le commentaire ne nomme pas de mode — 30 m, 60 m, FT4 80 m, FT4 17 m et 12 m tombaient dans le bloc DATA générique.",
|
||||
"OmniRig (Yaesu) : avec le split actif, se rendre sur un spot déplace LES DEUX VFO — sur un FT-2000 l’écriture n’atteignait que le VFO TX, donc l’émetteur QSYait et le récepteur restait derrière.",
|
||||
"Réseau Icom : Wake-on-LAN — une radio complètement éteinte (serveur LAN coupé) est réveillée par un paquet magique vers sa MAC mémorisée dès qu’une session est voulue, et la console avec son bouton ON revient sans aller au shack.",
|
||||
"Déjà contacté : une recherche lente ne peut plus écraser une plus récente — taper un second indicatif rapidement pouvait laisser les QSO du call précédent affichés sous le nom du nouveau."
|
||||
"Déjà contacté : une recherche lente ne peut plus écraser une plus récente — taper un second indicatif rapidement pouvait laisser les QSO du call précédent affichés sous le nom du nouveau.",
|
||||
"Réseau Icom : OpsLog envoie désormais ses propres pings toutes les 500 ms sur les trois flux, comme RS-BA1 et wfview — un client qui ne faisait que répondre était jugé absent par la radio, qui cessait de servir le CI-V au bout d’une minute : les coupures récurrentes de son/CAT."
|
||||
]
|
||||
},
|
||||
{
|
||||
|
||||
Reference in New Issue