fix(icom): verify the data flag after a mode set, and correct it with 0x26
The IC-7760 acknowledges the 1A 06 data-mode command and stays in USB-D anyway, which left the operator unable to get back to plain USB from the console at all. After every mode set the flag is read back; on a mismatch it is said again with 0x26 — mode, data flag and filter in one frame, the form the newer rigs actually honour. Only on a mismatch, so rigs that predate 0x26 never see the command.
This commit is contained in:
+4
-2
@@ -7,14 +7,16 @@
|
|||||||
"Elecraft console: an SWR spike (the K3’s own blip at the end of an FT8 frame) no longer fades over twelve seconds — the peak shows briefly, then the meter returns straight to the live reading.",
|
"Elecraft console: an SWR spike (the K3’s own blip at the end of an FT8 frame) no longer fades over twelve seconds — the peak shows briefly, then the meter returns straight to the live reading.",
|
||||||
"Icom: the IC-7760 joins the model list (CI-V address B2h).",
|
"Icom: the IC-7760 joins the model list (CI-V address B2h).",
|
||||||
"Icom console: the IC-7760 gets its real attenuator steps — 6/12/18 dB.",
|
"Icom console: the IC-7760 gets its real attenuator steps — 6/12/18 dB.",
|
||||||
"Icom network audio: the RX stream is decoded correctly — mono is requested and the payload offset was confirmed on a real IC-7760, curing the garbled, clicking audio."
|
"Icom network audio: the RX stream is decoded correctly — mono is requested and the payload offset was confirmed on a real IC-7760, curing the garbled, clicking audio.",
|
||||||
|
"Icom: switching back from a data mode (USB-D1) to plain USB now sticks — if the rig ignores the data-flag command, it is repeated with the modern one-frame form (0x26). Seen on the IC-7760."
|
||||||
],
|
],
|
||||||
"fr": [
|
"fr": [
|
||||||
"Console Elecraft : le S-mètre est calibré sur un vrai K3 — S9 et les +dB correspondent désormais à l’affichage de la radio (il lisait environ deux points S trop bas).",
|
"Console Elecraft : le S-mètre est calibré sur un vrai K3 — S9 et les +dB correspondent désormais à l’affichage de la radio (il lisait environ deux points S trop bas).",
|
||||||
"Console Elecraft : un pic de ROS (le sursaut du K3 en fin de trame FT8) ne s’estompe plus pendant douze secondes — le pic s’affiche brièvement, puis le ros-mètre revient directement à la valeur réelle.",
|
"Console Elecraft : un pic de ROS (le sursaut du K3 en fin de trame FT8) ne s’estompe plus pendant douze secondes — le pic s’affiche brièvement, puis le ros-mètre revient directement à la valeur réelle.",
|
||||||
"Icom : l’IC-7760 rejoint la liste des modèles (adresse CI-V B2h).",
|
"Icom : l’IC-7760 rejoint la liste des modèles (adresse CI-V B2h).",
|
||||||
"Console Icom : l’IC-7760 reçoit ses vrais crans d’atténuateur — 6/12/18 dB.",
|
"Console Icom : l’IC-7760 reçoit ses vrais crans d’atténuateur — 6/12/18 dB.",
|
||||||
"Audio réseau Icom : le flux RX est décodé correctement — le mono est demandé et l’offset du payload a été confirmé sur un vrai IC-7760, ce qui guérit le son inaudible et les clics."
|
"Audio réseau Icom : le flux RX est décodé correctement — le mono est demandé et l’offset du payload a été confirmé sur un vrai IC-7760, ce qui guérit le son inaudible et les clics.",
|
||||||
|
"Icom : revenir d’un mode data (USB-D1) au USB simple tient désormais — si la radio ignore la commande du drapeau data, elle est répétée sous la forme moderne en une trame (0x26). Constaté sur l’IC-7760."
|
||||||
]
|
]
|
||||||
},
|
},
|
||||||
{
|
{
|
||||||
|
|||||||
@@ -36,6 +36,7 @@ const (
|
|||||||
CmdVfoFreq = 0x25 // read a specific VFO's freq (sub 0x00 selected, 0x01 unselected)
|
CmdVfoFreq = 0x25 // read a specific VFO's freq (sub 0x00 selected, 0x01 unselected)
|
||||||
CmdPTT = 0x1C // sub 0x00 = PTT
|
CmdPTT = 0x1C // sub 0x00 = PTT
|
||||||
CmdExtra = 0x1A // sub 0x06 = data mode on modern Icoms
|
CmdExtra = 0x1A // sub 0x06 = data mode on modern Icoms
|
||||||
|
CmdModeDataFil = 0x26 // sub 0x00 = selected VFO: mode + data flag + filter in one frame
|
||||||
CmdReadID = 0x19 // sub 0x00 = rig's own CI-V address (identifies model)
|
CmdReadID = 0x19 // sub 0x00 = rig's own CI-V address (identifies model)
|
||||||
CmdPower = 0x18 // power on/off (sub 0x01 = on, 0x00 = off; on needs an FE wake preamble)
|
CmdPower = 0x18 // power on/off (sub 0x01 = on, 0x00 = off; on needs an FE wake preamble)
|
||||||
|
|
||||||
|
|||||||
@@ -559,6 +559,18 @@ func (b *IcomSerial) SetMode(mode string) error {
|
|||||||
}
|
}
|
||||||
// Filter 0x01 (FIL1) is the conventional default for the data-mode set.
|
// Filter 0x01 (FIL1) is the conventional default for the data-mode set.
|
||||||
_ = b.execIdempotent("set data mode", civ.CmdExtra, civ.SubDataMode, dataByte, 0x01)
|
_ = b.execIdempotent("set data mode", civ.CmdExtra, civ.SubDataMode, dataByte, 0x01)
|
||||||
|
// Trust, then verify: the IC-7760 acknowledges 1A 06 and stays in USB-D
|
||||||
|
// anyway, which left an operator unable to get back to plain USB at all.
|
||||||
|
// When the readback disagrees, say it again with 0x26 — mode, data flag and
|
||||||
|
// filter in one frame, the command the newer rigs actually honour. Only on
|
||||||
|
// a mismatch, so rigs that predate 0x26 never see it.
|
||||||
|
if got := b.readDataMode(); got != data {
|
||||||
|
if err := b.execIdempotent("set mode+data (0x26)", civ.CmdModeDataFil, 0x00, code, dataByte, 0x01); err != nil {
|
||||||
|
applog.Printf("icom: data flag stuck at %v after mode %s, and 0x26 failed too: %v", got, mode, err)
|
||||||
|
} else {
|
||||||
|
applog.Printf("icom: data flag stuck after 1A06, corrected via 0x26 (mode %s)", mode)
|
||||||
|
}
|
||||||
|
}
|
||||||
return nil
|
return nil
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||