feat: Ultrabeam over USB, Paper QSL from the awards grid, per-role schemas
Ultrabeam on a serial port never worked, and three faults were stacked so
each hid the next:
- Stop() did not wait for the poll loop, so a stopped client kept the COM
port. Every later client then failed with "Serial port busy" — the
program holding it being OpsLog itself.
- startUltrabeam tore the old client down CONCURRENTLY with starting the
new one, and "Test connection" built a second client on a port already
ours. Harmless over TCP, fatal on a port with one owner.
- A silent serial port returns (0, nil) and bufio retries that a hundred
times: a 4 s timeout became ~7 minutes of a frozen poll loop logging
nothing.
The controller then answered at once. Confirmed on hardware: the USB cable
presents TWO COM ports, only the second reaches the controller, and only at
19200 baud — so the speed is pinned in code (an FTDI cable opens at any
speed, and a wrong one is indistinguishable from a dead controller) and the
port field says which one to pick. The first exchange after each connect is
hex-dumped, which separates silence from a wrong baud from a misread frame.
Databases now carry only the tables their role needs. Every target used to
get the whole migration set, so a shared MySQL logbook grew settings and
station_profiles tables nothing ever wrote to — an operator inspecting the
server could not tell which copy was authoritative. Statements are filtered
by role, unknown tables are kept in both (fail-safe), and existing databases
are cleaned once, dropping only EMPTY tables. Settings → Database gains a
Compact button, since SQLite frees pages inside the file and never shrinks it.
Also:
- Awards: the callsigns behind a cell open the QSL Manager on Paper QSL,
searched, ready for the card dates.
- The record button no longer goes missing after an update: whether manual
recording is possible is a per-profile question that was asked once, at
startup, before the profile was known.
- Alert rules and filter presets confirm that they were saved.
- Spot clicks on the radio panadapter carry the POTA park into F3.
- The build gate is re-checked wherever the active callsign can change; it
ran at startup alone, and a fresh install has no callsign then.
This commit is contained in:
@@ -76,3 +76,30 @@ func TestMotorTuneKHzForBandFallsBack(t *testing.T) {
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
// The Ultrabeam's USB link answers on 19200 and on nothing else — confirmed on
|
||||
// hardware, where 9600 opened the port and returned not one byte. A speed with a
|
||||
// single right answer must not be storable as anything else, whatever an older
|
||||
// config or a hand-edited setting says.
|
||||
func TestNormMotorBaud(t *testing.T) {
|
||||
for _, tc := range []struct {
|
||||
typ, transport string
|
||||
in, want int
|
||||
}{
|
||||
{"ultrabeam", "serial", 9600, 19200},
|
||||
{"ultrabeam", "serial", 0, 19200},
|
||||
{"ultrabeam", "serial", 115200, 19200},
|
||||
// Over TCP the speed is the adapter's business, not ours.
|
||||
{"ultrabeam", "tcp", 9600, 9600},
|
||||
// The SteppIR controller really does run at several speeds.
|
||||
{"steppir", "serial", 4800, 4800},
|
||||
{"steppir", "serial", 19200, 19200},
|
||||
// Nonsense falls back rather than reaching the driver.
|
||||
{"steppir", "serial", 0, 9600},
|
||||
{"steppir", "serial", 999999, 9600},
|
||||
} {
|
||||
if got := normMotorBaud(tc.typ, tc.transport, tc.in); got != tc.want {
|
||||
t.Errorf("normMotorBaud(%q, %q, %d) = %d, want %d", tc.typ, tc.transport, tc.in, got, tc.want)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue