feat: report UI crashes instead of showing a blank window

Two white-screen reports are open — one after logging a 10 GHz QSO, one on
starting a DVK auto-call — and neither could be investigated, for the same
reason: a render error emptied the window and left NOTHING. No line in
opslog.log, no dialog, nothing the operator could send but the words "white
screen". A fault the user cannot report is a fault that cannot be fixed.

So before hunting either trigger, the reporting path:

  - An error boundary catches a render throw, writes the error and component
    stack to the app log through the new LogUIError binding, and shows it on
    screen — selectable, with Copy and Reload.
  - Global handlers catch what a boundary cannot: throws from timers, event
    handlers and rejected promises. An auto-call loop lives entirely in
    callbacks, which is exactly where the second report came from, and those
    leave no trace at all today.

It deliberately does not try to resume: React cannot promise sane state after a
render throw, and a half-working logger would be worse than a clear stop.

This does not fix either crash. It makes the next occurrence arrive with its
cause attached, which is the step that has been missing.
This commit is contained in:
2026-07-30 14:36:19 +02:00
parent 75c02ea2a0
commit d322ea9a07
6 changed files with 155 additions and 7 deletions
+4 -2
View File
@@ -9,7 +9,8 @@
"Rotator control now covers any GS-232A controller, ERC (Easy Rotor Control) included: the serial speed is selectable and the entry is named after the protocol rather than one device. Set the ERC to GS-232 emulation, not Hy-Gain DCU-1.",
"Native Kenwood CAT: a sixth backend talks straight to a TS-590, TS-890, TS-990 or TS-2000 over its serial port — frequency, mode, VFO, split and PTT — with no OmniRig in between. Elecraft K3/K4 speak the same dialect. Pick \"Kenwood (native)\" in Settings → CAT.",
"Icom and Xiegu: a CI-V frame read at the wrong offset no longer turns into a frequency. Values such as 16445550000 Hz appeared in the status bar while the rig sat on 145.550 MHz — the decoder treated non-decimal bytes as digits. Such frames are now refused and the last good reading stands.",
"Settings → CAT can log the CI-V protocol: every frame to and from an Icom or Xiegu, as hex. For reporting a radio that answers oddly — a button that does the wrong thing, a frequency that jumps — where a description alone leaves the cause to guesswork."
"Settings → CAT can log the CI-V protocol: every frame to and from an Icom or Xiegu, as hex. For reporting a radio that answers oddly — a button that does the wrong thing, a frequency that jumps — where a description alone leaves the cause to guesswork.",
"A crash in the window no longer leaves a blank screen. The error is written to the app log and shown on screen, selectable, with a button to copy it and one to reload — so a fault can be reported with its cause instead of a description of an empty window."
],
"fr": [
"Les entrées de réglages Antenna Genius et Tuner Genius portent une petite marque 4O3A : les panneaux pilotant ce matériel se repèrent d'un coup d'œil dans le menu.",
@@ -18,7 +19,8 @@
"Le contrôle de rotator couvre désormais tout contrôleur GS-232A, ERC (Easy Rotor Control) compris : la vitesse du port série est sélectionnable et l'entrée porte le nom du protocole plutôt que celui d'un seul appareil. Réglez l'ERC sur l'émulation GS-232, pas Hy-Gain DCU-1.",
"CAT Kenwood natif : un sixième backend parle directement à un TS-590, TS-890, TS-990 ou TS-2000 par son port série — fréquence, mode, VFO, split et PTT — sans OmniRig. Les Elecraft K3/K4 parlent le même dialecte. À choisir sous « Kenwood (natif) » dans Réglages → CAT.",
"Icom et Xiegu : une trame CI-V lue au mauvais décalage ne se transforme plus en fréquence. Des valeurs comme 16445550000 Hz apparaissaient dans la barre d'état alors que la radio était sur 145,550 MHz — le décodeur prenait des octets non décimaux pour des chiffres. Ces trames sont désormais refusées et la dernière lecture valable est conservée.",
"Réglages → CAT permet de journaliser le protocole CI-V : chaque trame échangée avec un Icom ou un Xiegu, en hexadécimal. Pour signaler une radio qui répond de travers — un bouton qui fait autre chose, une fréquence qui saute — là où une description seule laisse la cause à la devinette."
"Réglages → CAT permet de journaliser le protocole CI-V : chaque trame échangée avec un Icom ou un Xiegu, en hexadécimal. Pour signaler une radio qui répond de travers — un bouton qui fait autre chose, une fréquence qui saute — là où une description seule laisse la cause à la devinette.",
"Un plantage de la fenêtre ne laisse plus un écran vide. L'erreur est écrite dans le journal et affichée à l'écran, sélectionnable, avec un bouton pour la copier et un pour recharger — de quoi signaler un défaut avec sa cause plutôt qu'une description de fenêtre vide."
]
},
{