feat: support ERC rotator controllers through the existing GS-232A backend
An ERC (Easy Rotor Control, incl. ERC Mini) emulates Yaesu GS-232A/B, which is
exactly what the backend written for the microHAM ARCO already speaks — azimuth
out (Maaa), azimuth in (C), stop (S), which is the whole of what was asked for.
So this is two small gaps rather than a new backend:
- Serial speed was hardcoded to 9600. An ARCO's virtual COM ignores it, but an
ERC runs at whatever its own configuration sets, and a mismatch reads as a
dead rotator. It is now selectable beside the COM port.
- The entry was called "microHAM ARCO", so an ERC owner would never have found
it. It is named after the PROTOCOL now: "GS-232A controller (microHAM ARCO,
ERC…)".
The help text states the condition plainly in both languages, because it is the
one thing that will otherwise waste an evening: an ERC left on Hy-Gain DCU-1
speaks a different command set and simply will not answer.
Untested on hardware — I have no ERC here, and the GS-232 path itself is proven
on a real ARCO.
This commit is contained in:
@@ -1,6 +1,12 @@
|
||||
// Package gs232 drives rotator controllers that speak the Yaesu GS-232A
|
||||
// protocol, over a raw TCP socket or a serial COM port. The target device is
|
||||
// the microHAM ARCO: both its LAN "CONTROL PROTOCOL" setting (a TCP port) and
|
||||
// protocol, over a raw TCP socket or a serial COM port.
|
||||
//
|
||||
// Any controller set to GS-232A works, which is most of them: the microHAM ARCO
|
||||
// natively, and the ERC family (Easy Rotor Control — ERC Mini, ERC interface),
|
||||
// which EMULATES GS-232A/B over its USB port. An ERC can also be configured for
|
||||
// Hy-Gain DCU-1, a different command set entirely, so it must be set to GS-232.
|
||||
//
|
||||
// On the ARCO: both its LAN "CONTROL PROTOCOL" setting (a TCP port) and
|
||||
// its USB port ("USB CONTROL PROTOCOL", a virtual COM where the baud rate is
|
||||
// irrelevant) can be set to speak Yaesu GS-232A — so OpsLog controls it
|
||||
// directly, no PstRotator in between. ARCO accepts up to four parallel LAN
|
||||
@@ -37,7 +43,12 @@ const (
|
||||
type Client struct {
|
||||
Host string
|
||||
Port int
|
||||
ComPort string // serial transport: "COM5" etc. (ARCO USB virtual COM — any baud)
|
||||
ComPort string // serial transport: "COM5" etc.
|
||||
// Baud matters on some controllers. An ARCO's USB virtual COM ignores it, but
|
||||
// an ERC (Easy Rotor Control) runs at whatever rate its own configuration
|
||||
// sets — commonly 9600 or 19200 — and a mismatch reads as a dead rotator.
|
||||
// Zero keeps the historical 9600.
|
||||
Baud int
|
||||
}
|
||||
|
||||
// New returns a TCP Client with sane defaults applied for empty fields. There
|
||||
@@ -56,8 +67,8 @@ func New(host string, port int) *Client {
|
||||
// NewSerial returns a Client talking over the ARCO's USB virtual COM port. The
|
||||
// baud rate is irrelevant on USB per the ARCO manual (8N1 framing matters); we
|
||||
// open at 9600 which also suits a real RS-232 hookup left at its default.
|
||||
func NewSerial(comPort string) *Client {
|
||||
return &Client{ComPort: comPort}
|
||||
func NewSerial(comPort string, baud int) *Client {
|
||||
return &Client{ComPort: comPort, Baud: baud}
|
||||
}
|
||||
|
||||
// roundTrip opens a connection (TCP or serial per the client's config), sends
|
||||
@@ -66,9 +77,13 @@ func NewSerial(comPort string) *Client {
|
||||
func (c *Client) roundTrip(cmd string, wantReply bool) (string, error) {
|
||||
var conn io.ReadWriteCloser
|
||||
if c.ComPort != "" {
|
||||
sp, err := serial.Open(c.ComPort, &serial.Mode{BaudRate: 9600})
|
||||
baud := c.Baud
|
||||
if baud <= 0 {
|
||||
baud = 9600
|
||||
}
|
||||
sp, err := serial.Open(c.ComPort, &serial.Mode{BaudRate: baud})
|
||||
if err != nil {
|
||||
return "", fmt.Errorf("open ARCO %s: %w", c.ComPort, err)
|
||||
return "", fmt.Errorf("open rotator %s @ %d baud: %w", c.ComPort, baud, err)
|
||||
}
|
||||
_ = sp.SetReadTimeout(200 * time.Millisecond)
|
||||
conn = sp
|
||||
|
||||
Reference in New Issue