chore(changelog): open 0.26.15 with the TCI audio work
The RDA and Elecraft SWR entries move with it: both were written after v0.26.14 was tagged, so they ship in the version that carries them rather than in the one already on operators' machines.
This commit is contained in:
+18
-6
@@ -1,4 +1,20 @@
|
||||
[
|
||||
{
|
||||
"version": "0.26.15",
|
||||
"date": "",
|
||||
"en": [
|
||||
"SunSDR / ExpertSDR3: the radio's audio now travels over the TCI link itself. Pick 'Radio (TCI network audio)' as the From Radio or To Radio device and the QSO recorder and the voice keyer work with no virtual cable, no second sound card and nothing to set up in the Windows mixer.",
|
||||
"For transmit, ExpertSDR3's own transmit audio source must be set to TCI rather than the microphone — it is remembered per mode, so setting it in SSB does not set it in DIGU. OpsLog says so within a fifth of a second rather than transmitting silence.",
|
||||
"Awards, RDA district comparison: the list stays where it was put. It was thrown back to the first row every three seconds, which made a long list of contacts to correct impossible to work through.",
|
||||
"Elecraft console: the SWR bar works. The radio answers SW; with three digits in tenths of a ratio — SW023 is 2.3:1 — and OpsLog was reading four, so every answer was discarded and the bar stayed empty."
|
||||
],
|
||||
"fr": [
|
||||
"SunSDR / ExpertSDR3 : l'audio de la radio passe désormais par la liaison TCI elle-même. Choisis « Radio (TCI network audio) » comme périphérique From Radio ou To Radio et l'enregistreur de QSO comme le manipulateur vocal fonctionnent sans câble virtuel, sans seconde carte son et sans rien à régler dans le mixeur Windows.",
|
||||
"Pour l'émission, la source audio d'émission d'ExpertSDR3 doit être réglée sur TCI et non sur le micro — elle est mémorisée par mode, donc la régler en SSB ne la règle pas en DIGU. OpsLog le dit en deux dixièmes de seconde au lieu d'émettre du silence.",
|
||||
"Diplômes, comparaison des districts RDA : la liste reste où on l'a laissée. Elle revenait à la première ligne toutes les trois secondes, ce qui rendait impraticable une longue liste de contacts à corriger.",
|
||||
"Console Elecraft : la barre de ROS fonctionne. La radio répond à SW; par trois chiffres en dixièmes de rapport — SW023 vaut 2,3:1 — et OpsLog en lisait quatre, si bien que chaque réponse était jetée et la barre restait vide."
|
||||
]
|
||||
},
|
||||
{
|
||||
"version": "0.26.14",
|
||||
"date": "",
|
||||
@@ -14,9 +30,7 @@
|
||||
"An editable list of satellites (Preferences → Lists → Satellites). The satellite-name field on the entry form offers them as a dropdown, alphabetically, and still accepts anything typed. SAT_NAME is compared character for character by the awards and by LoTW — AO-91 and AO91 are two different satellites to everything downstream — so a remembered spelling beats one retyped on every pass.",
|
||||
"Awards, RDA district comparison: the conflict list is taller and scrolls, a callsign in it opens the contact, and the compare and fill-districts buttons say they are working. The list was capped at about six visible rows out of two hundred, in a panel that would not scroll to the rest, and nothing in it could be acted on.",
|
||||
"Preferences no longer redraw with the main window. Being a child of the main view, the whole panel was rebuilt on every cluster spot and every CAT update — several times a second on a busy evening — which looked like a page refreshing constantly and made buttons miss their clicks, the element under the pointer being replaced between the press and the release.",
|
||||
"A launch that fails before the window exists now says why, on screen and in a startup log kept outside the data folder. Every fault before that point was invisible — no window, no folder, no file to read — and the causes are named: a missing or blocked WebView2 runtime, an 'Edge blocker' tool stopping the engine OpsLog draws its interface with, a folder Windows refuses to write to, a copy already running. WebView2 also gets its own profile folder on the local disk, retries without GPU acceleration after a launch that hung, and can use a fixed-version runtime dropped beside OpsLog where the installer cannot run.",
|
||||
"Awards, RDA district comparison: the list stays where it was put. It was thrown back to the first row every three seconds, which made a long list of contacts to correct impossible to work through.",
|
||||
"Elecraft console: the SWR bar works. The radio answers SW; with three digits in tenths of a ratio — SW023 is 2.3:1 — and OpsLog was reading four, so every answer was discarded and the bar stayed empty."
|
||||
"A launch that fails before the window exists now says why, on screen and in a startup log kept outside the data folder. Every fault before that point was invisible — no window, no folder, no file to read — and the causes are named: a missing or blocked WebView2 runtime, an 'Edge blocker' tool stopping the engine OpsLog draws its interface with, a folder Windows refuses to write to, a copy already running. WebView2 also gets its own profile folder on the local disk, retries without GPU acceleration after a launch that hung, and can use a fixed-version runtime dropped beside OpsLog where the installer cannot run."
|
||||
],
|
||||
"fr": [
|
||||
"Console Elecraft : les mesures d'émission sont lues dès que la RADIO se déclare en émission, et plus seulement quand OpsLog l'a mise en émission. Passer en émission par le PTT de façade, une pédale ou le bouton du micro laissait le panneau croire à une réception — et comme les barres de puissance et de ROS ne sont lues qu'en émission, elles ne l'étaient jamais pour qui manipule à la main.",
|
||||
@@ -30,9 +44,7 @@
|
||||
"Une liste de satellites éditable (Préférences → Listes → Satellites). Le champ du nom de satellite dans la saisie les propose en liste déroulante, par ordre alphabétique, et accepte toujours ce qu'on tape. SAT_NAME est comparé caractère par caractère par les diplômes et par LoTW — AO-91 et AO91 sont deux satellites différents pour tout ce qui suit — donc une orthographe mémorisée vaut mieux qu'une ressaisie à chaque passage.",
|
||||
"Diplômes, comparaison des districts RDA : la liste des divergences est plus haute et défile, un indicatif y ouvre le contact, et les boutons comparer et remplir les districts disent qu'ils travaillent. Elle était limitée à six lignes visibles environ sur deux cents, dans un panneau qui ne défilait pas pour montrer le reste, et rien n'y était actionnable.",
|
||||
"Les préférences ne se redessinent plus au rythme de la fenêtre principale. Étant un enfant de la vue principale, tout le panneau était reconstruit à chaque spot du cluster et à chaque mise à jour CAT — plusieurs fois par seconde un soir chargé — ce qui donnait l'impression d'une page qui se rafraîchit sans arrêt et faisait rater les clics, l'élément sous le pointeur étant remplacé entre l'appui et le relâchement.",
|
||||
"Un lancement qui échoue avant l'apparition de la fenêtre dit désormais pourquoi, à l'écran et dans un journal de démarrage tenu hors du dossier data. Toute panne survenant avant ce point était invisible — pas de fenêtre, pas de dossier, aucun fichier à lire — et les causes sont nommées : un runtime WebView2 absent ou bloqué, un « bloqueur Edge » qui empêche le moteur avec lequel OpsLog dessine son interface, un dossier où Windows refuse d'écrire, une copie déjà lancée. WebView2 reçoit aussi son propre dossier de profil sur le disque local, réessaie sans accélération GPU après un lancement bloqué, et peut utiliser un runtime en version fixe déposé à côté d'OpsLog là où l'installateur ne peut pas s'exécuter.",
|
||||
"Diplômes, comparaison des districts RDA : la liste reste où on l'a laissée. Elle revenait à la première ligne toutes les trois secondes, ce qui rendait impraticable une longue liste de contacts à corriger.",
|
||||
"Console Elecraft : la barre de ROS fonctionne. La radio répond à SW; par trois chiffres en dixièmes de rapport — SW023 vaut 2,3:1 — et OpsLog en lisait quatre, si bien que chaque réponse était jetée et la barre restait vide."
|
||||
"Un lancement qui échoue avant l'apparition de la fenêtre dit désormais pourquoi, à l'écran et dans un journal de démarrage tenu hors du dossier data. Toute panne survenant avant ce point était invisible — pas de fenêtre, pas de dossier, aucun fichier à lire — et les causes sont nommées : un runtime WebView2 absent ou bloqué, un « bloqueur Edge » qui empêche le moteur avec lequel OpsLog dessine son interface, un dossier où Windows refuse d'écrire, une copie déjà lancée. WebView2 reçoit aussi son propre dossier de profil sur le disque local, réessaie sans accélération GPU après un lancement bloqué, et peut utiliser un runtime en version fixe déposé à côté d'OpsLog là où l'installateur ne peut pas s'exécuter."
|
||||
]
|
||||
},
|
||||
{
|
||||
|
||||
Reference in New Issue
Block a user