feat: HAMLOG.online upload and confirmations, Yaesu antenna, a named port holder

HAMLOG.online is a seventh external service: one API key, one ADIF record per
QSO, immediate / delayed / on-close like the rest. They publish no API
documentation, so the protocol is read from THEIR OWN client — the HAMLOG Agent
(github.com/hamlogonline/Agent), which is the authoritative source short of
asking them:

	POST https://hamlog.online/api/agent/
	{"ADIFADD": {"APIKEY": k, "ADIFDATA": record}}   → {"STATUS":"OK"}
	{"KEYSTATUS": {"APIKEY": k}}                     → {"STATUS":"OK","CALLSIGN":…}

Success is STATUS == OK, not "no ERROR field": their failure carries ERROR and
no STATUS, and reading an unknown reply — a proxy page, a maintenance notice —
as an acceptance is how a contact goes missing without anyone noticing.

KEYSTATUS buys something no other service here offers: the key can be checked
BEFORE the first QSO, and the answer names the account. A key pasted from
another callsign is caught in the settings panel rather than through a week of
silent refusals.

Their confirmations are also an award source now, ticked like LoTW rather than
expressed through "custom". It reads the ADIF extras, not a column: the standard
names a field for hamlog.EU and none for hamlog.ONLINE, and borrowing the other
site's field would write a falsehood into every exported log. Three plausible
key names from their own export are accepted too, so nobody has to rename a
column by hand after an export.

Yaesu gains antenna selection (AN), remembered per band — the antenna picked on
a band comes back with it, with no table to fill in anywhere. Rigs with one
socket never answer AN and never show the row; the log says which case it is.

And a serial port that is refused now names its likely holder. OmniRig stays
resident once activated and keeps the port of the rig configured in it, so a
native backend never gets it — "Serial port busy" alone accused nobody, and an
FTDX10 spent a morning being blamed for it.
This commit is contained in:
2026-08-23 12:18:27 +02:00
parent 3014796c1d
commit ee148732dd
21 changed files with 603 additions and 18 deletions
+39 -5
View File
@@ -50,11 +50,15 @@ type YaesuTXState struct {
Squelch int `json:"squelch"` // 0-100
AGC string `json:"agc,omitempty"`
Preamp int `json:"preamp"` // 0=IPO, 1=AMP1, 2=AMP2
Att int `json:"att"` // 0=off, else dB
NB bool `json:"nb"`
NR bool `json:"nr"`
NRLevel int `json:"nr_level"` // 1-15
Narrow bool `json:"narrow"` // NAR filter
// Antenna is the selected jack, 1-3, or 0 when the rig has no AN command —
// an FT-891 or FT-991A has a single socket and answers nothing. 0 is what
// tells the panel to draw no selector at all rather than a dead one.
Antenna int `json:"antenna"`
Att int `json:"att"` // 0=off, else dB
NB bool `json:"nb"`
NR bool `json:"nr"`
NRLevel int `json:"nr_level"` // 1-15
Narrow bool `json:"narrow"` // NAR filter
// SWR is the RATIO (1.0, 1.5…), computed from the reflection coefficient —
// what an operator reads on the rig, not a percentage of meter travel.
SWR float64 `json:"swr"`
@@ -80,6 +84,7 @@ type YaesuController interface {
SetYaesuSquelch(int) error
SetYaesuAGC(string) error
SetYaesuPreamp(int) error
SetYaesuAntenna(int) error
SetYaesuAtt(int) error
SetYaesuNB(bool) error
SetYaesuNR(bool) error
@@ -239,6 +244,24 @@ func (y *Yaesu) readPanelSettings() {
if v, ok := y.askNum("PA0;", "PA0", 1); ok {
y.panel.Preamp = v
}
// ANTENNA. "AN0;" → "AN01;" — the first digit is the receiver (0 = main,
// 1 = sub on an FTDX101), the second the jack. A rig with one socket does
// not implement it and simply says nothing, which askNum reports as
// not-ok — and 0 then means "no antenna switching here".
if v, ok := y.askNum("AN0;", "AN0", 1); ok {
if y.panel.Antenna == 0 {
debugLog.Printf("yaesu: antenna select available (AN0; → %d)", v)
}
y.panel.Antenna = v
} else {
// Said once, at the first read: an operator who expects the ANT row and
// does not get it should find the reason in the log rather than wonder
// whether OpsLog forgot the feature.
if y.panel.Antenna != -1 {
debugLog.Printf("yaesu: no answer to AN0; — this rig has no antenna selection, the ANT row stays hidden")
}
y.panel.Antenna = -1
}
if v, ok := y.askNum("RA0;", "RA0", 1); ok {
y.panel.Att = yaesuAttDB(v)
}
@@ -356,6 +379,17 @@ func (y *Yaesu) SetYaesuPreamp(n int) error {
return y.setAndRefresh(fmt.Sprintf("PA0%d;", clampInt(n, 0, 2)))
}
// SetYaesuAntenna selects an antenna jack (1-3) on the main receiver.
//
// Verified against the FTDX10 command set; the FTDX101 adds a third jack and a
// sub receiver, which is the "0" in AN0 — the day someone drives a sub receiver
// from here it becomes a parameter rather than a constant. A rig without the
// command ignores it, and readPanelSettings then keeps Antenna at 0, so the
// control never appears in the first place.
func (y *Yaesu) SetYaesuAntenna(n int) error {
return y.setAndRefresh(fmt.Sprintf("AN0%d;", clampInt(n, 1, 3)))
}
func (y *Yaesu) SetYaesuAtt(db int) error {