diag(icom net): name the audio stream when CI-V goes quiet

The RX audio stream is experimental and shares the rig's session with
CI-V. The shape in an operator's log is unmistakable: audio packets
arriving by the hundred while not one CI-V reply comes back, the watchdog
tearing the session down, twenty seconds' pause, and the whole thing
again — read from outside as "the Icom keeps disconnecting", with
nothing pointing at the switch that would end it.

The log now says it, and names the setting. icomAudio counts what it has
delivered so the line distinguishes "audio is enabled" from "audio is
arriving", which is the half that makes it a suspect.
This commit is contained in:
2026-09-06 17:42:37 +02:00
parent 507d1f0882
commit f2168d339b
3 changed files with 30 additions and 3 deletions
+4 -2
View File
@@ -6,13 +6,15 @@
"FT map: the callsign, square and report show on hover again. The invisible circle that catches the clicks sits on top of the dot, so it takes the hover too — and the label was bound only to the dot underneath, which left the map silent from the moment the stations became clickable.",
"ADIF export: a record is written on one line again. ADDRESS is a multi-line field by the standard and callbooks and other loggers fill it that way — “Kabul”, four blank lines, “Afghanistan” — and OpsLog wrote it out as it was, so a record ran down a dozen lines with the next apparently starting in the middle of the page. Line breaks inside a value are now joined with a comma, which is how an address reads on one line anyway. The files were always valid (ADIF counts bytes); they were unreadable.",
"Icom over the network: a rig left in standby no longer sits in a dial-and-drop loop. The clock that bounds “the control link answers but no CI-V comes back” belongs to a session and was never cleared when a new one opened, so every fresh session started already past its grace — torn down at once, redialled twenty seconds later, and torn down again for as long as the radio was asleep. Silent since connect is now read as what it is: a rig in standby, with the session kept so it can be woken.",
"The Icom console appears whenever the configured radio is an Icom, not only once the rig is talking — the console is where the power-ON button lives, so it used to be missing at the one moment it was needed. The consoles configured backend also follows a radio switched from the status bar, instead of waiting for a trip through Settings and a Save that changed nothing."
"The Icom console appears whenever the configured radio is an Icom, not only once the rig is talking — the console is where the power-ON button lives, so it used to be missing at the one moment it was needed. The consoles configured backend also follows a radio switched from the status bar, instead of waiting for a trip through Settings and a Save that changed nothing.",
"Icom over the network: when CI-V goes quiet while the experimental RX audio stream is still delivering, the log now says so and names the switch to try. The two share the rigs session, and the shape in the field is exactly that — hundreds of audio packets arriving, not one CI-V reply, the watchdog tearing the session down, and the whole thing starting again."
],
"fr": [
"Carte FTx : lindicatif, le locator et le report réapparaissent au survol. Le cercle invisible qui capte les clics est au-dessus du point, donc il capte aussi le survol — et l’étiquette n’était liée quau point du dessous, ce qui rendait la carte muette dès que les stations sont devenues cliquables.",
"Export ADIF : un enregistrement tient de nouveau sur une ligne. ADDRESS est un champ multiligne selon la norme, et les callbooks comme les autres logiciels le remplissent ainsi — « Kabul », quatre lignes vides, « Afghanistan » — quOpsLog recopiait tel quel : un enregistrement s’étalait sur une douzaine de lignes, le suivant semblant commencer au milieu de la page. Les retours à la ligne dans une valeur sont désormais réunis par une virgule, ce qui est de toute façon la façon de lire une adresse sur une ligne. Les fichiers étaient valides (lADIF compte les octets) ; ils étaient illisibles.",
"Icom en réseau : un poste laissé en veille ne tourne plus en boucle connexion/déconnexion. Lhorloge qui borne « la liaison de contrôle répond mais aucun CI-V ne revient » appartient à une session et n’était jamais remise à zéro à louverture de la suivante : chaque nouvelle session démarrait déjà au-delà de son délai de grâce — coupée aussitôt, rappelée vingt secondes plus tard, recoupée, aussi longtemps que la radio dormait. « Silencieux depuis la connexion » se lit désormais pour ce que cest : un poste en veille, dont on garde la session pour pouvoir le réveiller.",
"La console Icom saffiche dès que la radio configurée est un Icom, et pas seulement quand le poste parle — cest là que se trouve le bouton dallumage, il manquait donc au seul moment où il servait. Le backend configuré suit aussi un changement de radio fait depuis la barre d’état, au lieu dattendre un passage dans les réglages et un « Enregistrer » qui ne changeait rien."
"La console Icom saffiche dès que la radio configurée est un Icom, et pas seulement quand le poste parle — cest là que se trouve le bouton dallumage, il manquait donc au seul moment où il servait. Le backend configuré suit aussi un changement de radio fait depuis la barre d’état, au lieu dattendre un passage dans les réglages et un « Enregistrer » qui ne changeait rien.",
"Icom en réseau : quand le CI-V devient muet alors que le flux audio expérimental continue darriver, le journal le dit et nomme loption à essayer. Les deux partagent la session du poste, et cest exactement la forme observée en vrai — des centaines de paquets audio, pas une réponse CI-V, le chien de garde qui coupe la session, et tout qui recommence."
]
},
{