rouggy cb430a22ee feat: Ultrabeam over USB, Paper QSL from the awards grid, per-role schemas
Ultrabeam on a serial port never worked, and three faults were stacked so
each hid the next:

  - Stop() did not wait for the poll loop, so a stopped client kept the COM
    port. Every later client then failed with "Serial port busy" — the
    program holding it being OpsLog itself.
  - startUltrabeam tore the old client down CONCURRENTLY with starting the
    new one, and "Test connection" built a second client on a port already
    ours. Harmless over TCP, fatal on a port with one owner.
  - A silent serial port returns (0, nil) and bufio retries that a hundred
    times: a 4 s timeout became ~7 minutes of a frozen poll loop logging
    nothing.

The controller then answered at once. Confirmed on hardware: the USB cable
presents TWO COM ports, only the second reaches the controller, and only at
19200 baud — so the speed is pinned in code (an FTDI cable opens at any
speed, and a wrong one is indistinguishable from a dead controller) and the
port field says which one to pick. The first exchange after each connect is
hex-dumped, which separates silence from a wrong baud from a misread frame.

Databases now carry only the tables their role needs. Every target used to
get the whole migration set, so a shared MySQL logbook grew settings and
station_profiles tables nothing ever wrote to — an operator inspecting the
server could not tell which copy was authoritative. Statements are filtered
by role, unknown tables are kept in both (fail-safe), and existing databases
are cleaned once, dropping only EMPTY tables. Settings → Database gains a
Compact button, since SQLite frees pages inside the file and never shrinks it.

Also:
  - Awards: the callsigns behind a cell open the QSL Manager on Paper QSL,
    searched, ready for the card dates.
  - The record button no longer goes missing after an update: whether manual
    recording is possible is a per-profile question that was asked once, at
    startup, before the profile was known.
  - Alert rules and filter presets confirm that they were saved.
  - Spot clicks on the radio panadapter carry the POTA park into F3.
  - The build gate is re-checked wherever the active callsign can change; it
    ran at startup alone, and a fresh install has no callsign then.
2026-08-22 14:07:00 +02:00
rouggy 65bbaa85f3 feat(antenna): three tracking modes for Ultrabeam and SteppIR
The follow loop only ever had one behaviour — re-tune once the rig moved
further than a fixed step. The SteppIR's own controller software offers three,
and operators arrive with that mental model: every frequency change, past a
threshold, or only on a band change. They are real operating trade-offs, not
preferences: "always" keeps resonance perfect at the cost of motors running
constantly (and on a SteppIR every move inhibits transmit while the elements
travel), "band" moves them a handful of times a day.

"Always" is implemented as the threshold mode with a 1 kHz threshold rather
than as a separate branch, so all modes keep the one deadband reference that
matters: the rig frequency last commanded for, NOT the antenna's own reported
frequency — a SteppIR flips its reported frequency between the commanded value
and its home value, which would re-issue a SET on nearly every poll and leave
the operator permanently unable to transmit.

Band mode compares against the band last COMMANDED for, not the rig's previous
band, so the first move after startup and any move made by hand still get
reconciled. It applies to the immediate spot-click path too: a click inside the
band the antenna is already resonant in moves nothing.

An unset or unrecognised mode resolves to the step mode, so every config
written before this option behaves exactly as it did.

Also routes the antenna settings block through t() — it was hardcoded English.
2026-08-12 08:31:44 +02:00