Every setting is per profile, amplifiers included — that is the whole point of
one profile per station. But the amplifier clients were built once at startup
and again only when Settings was saved, so switching profile left them on the
previous profile's port. An operator with an SPE on COM9 for HF and another on
COM10 for 6 m had to open Settings and press Save after every switch. Save is
not a connect button; switching profile is what asks for that hardware.
The amplifier is what was reported, but it was never alone: the motorized
antenna, the Antenna Genius and the Tuner Genius are configured the same way and
were started in the same two places. All four now restart on a profile switch,
asynchronously, exactly as a save does.
Rotators were already correct — their client is built per command rather than
held open, so they read the active profile every time.
Unconditional, like a save: comparing each device's configuration across
profiles to skip a reconnect would trade a second of downtime for the chance of
missing one. A test now keeps the two lists in lockstep — anything started at
boot must be re-applied on a profile switch or be named, with its reason, as
something that must not be.