The settings store is backed by the LOCAL SQLite config DB (wired before the
slow remote-MySQL logbook connect), so the "not ready" window is the brief
startup gap before OnStartup builds the store, not a MySQL delay. Fix behaviour
is unchanged; only the comments and changelog wording are corrected.
An update can clear the WebView's localStorage; the theme is then restored from
the portable DB pref, but GetUIPref returned ("", nil) while the settings store
was still starting (indistinguishable from a genuinely-unset pref), so the
self-heal gave up after ~2.4s and fell back to the light default.
GetUIPref now returns an error when the settings store isn't wired yet, and the
theme self-heal treats that as "not ready → keep retrying" (up to ~36s) vs a
real empty answer ("unset → keep default"). A dark theme survives the relaunch.
Some CW interfaces key on the opposite line level (transmit at rest / key
backwards). New "Invert keying (active-LOW)" toggle flips the asserted level for
both the CW and PTT lines, and the idle state drives both lines to their
inactive level accordingly so an active-low rig isn't left keyed at rest.
Default off = N1MM convention (line HIGH = active).
Adds a 4th CW keyer engine alongside K1EL WinKeyer, Icom CI-V and Flex CWX:
OpsLog bit-bangs the Morse itself on a serial control line (DTR keys CW, RTS
keys PTT — swappable), the hardware-keying method N1MM/WSJT use with a Yaesu
SCU-17 and generic interfaces. No WinKeyer chip needed.
- internal/winkeyer/serialcw.go: serialKeyer — worker goroutine, morse table,
WPM + Farnsworth timing (live speed changes), abortable, PTT lead-in/tail/hang.
- winkeyer.Config gains Type ("k1el"|"serial") + CWKeyLine ("dtr"|"rts");
Manager routes Connect/Send/Stop/SetSpeed/Backspace/Disconnect to it.
- app.go: keyWKCWLine setting; WinkeyerConnect sets Type from the engine.
- Settings -> CW Keyer: new "Serial port (DTR=CW/RTS=PTT)" engine with COM port,
key-line selector, speed/Farnsworth/lead-in/tail/PTT. Macros, auto-CQ and
<LOGQSO> reuse the WinKeyer path unchanged.
UNTESTED on hardware (no SCU-17 to hand): polarity assumes N1MM convention
(line HIGH = active). Weight not yet honoured; Farnsworth is.
- Station Control: the amplifier panel is now the exact same card as the FlexRadio panel (extracted shared AmpCard: OPERATE/STANDBY, ON/OFF, power level, output-power bar, live FWD/ID/temp meters). Every configured amp gets its own card — no dropdown.
- Help → "Send log to F4BPO" (only when SMTP is configured): e-mails opslog.log + previous session + crash log to the developer. New email.SendFiles for multi-attachment.
- Bulk edit: new "Frequency (MHz)" field sets freq_hz AND recomputes band; out-of-band values rejected. Fixes a run logged on a stale/default freq after CAT dropped.
- Cluster: Time column sorted lexically on the HHMMZ string, so spots after 0000Z sorted below 2359Z and looked frozen at the UTC rollover. Now sorts by real arrival time.
- Also folds in the DVK auto-CQ/2-column layout and Station Control dashboard batch (changelog 0.20.10, EN+FR).
Multi-amp: Settings->Amplifier becomes a list (amps.json, legacy single-amp keys auto-migrate to entry #1); one client per enabled amp with per-id bindings (GetAmplifiers/SaveAmplifiers/GetAmpStatuses/AmpOperate/AmpPower/AmpPowerLevel/AmpFanMode); legacy a.pgxl/a.spe/a.acom point at the first enabled amp of each family. Amp cards in FlexPanel and Station Control gain a dropdown to pick the amp; the status bar shows one clickable chip per amp. Use case: two SPEs run in parallel.
Flex v4 DSP (8000/Aurora): NRL/ANFL (lms_nr/lms_anf), NRS (speex_nr), NRF (nrf) with level sliders, RNN (rnnoise) and ANFT on/off — keys per the FlexLib slice docs; the section only shows when the radio reports these keys (dsp_v4 flag), so 6000-series panels are unchanged.
The station-control code rebuilt a fresh driver on every status poll and every
relay set. Stateful boards (Denkovi FTDI D2XX, USB-serial) hold an OS handle only
one opener can own, so the first poll opened the board and leaked the handle, and
every poll after failed with 'device in use' — the relays greyed out a second
after Save and auto-control never switched. Drivers are now cached per device and
reused, closed on config change. Adds a Test-connection button + detect feedback
in the device editor (reported by VK4MA).
When the configured amplifier is an SPE Expert (not the PowerGenius), the Flex
panel now shows an SPE control card — the Flex doesn't report SPE amps, so it's
driven by OpsLog's own SPE link. The PowerGenius fan-mode control is hidden when
the amp type isn't PowerGenius.
Opening About now fires a fresh CheckForUpdate with a 'Checking…' state, and
clears the update banner when the latest check finds nothing — so it reflects
reality instead of the last periodic check.
Adds GetChangelog (all entries up to the running version, no seen-marker change)
and a Help menu 'What's new' item that reopens the changelog dialog on demand.
Embeds changelog.json (per-version EN + FR notes, curated from the release's
commits). GetWhatsNew compares the stored last-seen version with the running
build and returns the notes for every newer version, once, then advances the
marker. A dialog shows them in the UI language on the first launch after update.
Seeded with the 0.20.5 notes.
Day/Week/Month/Year now show the anchor day hour-by-hour, the last 7 days, the
last 30 days, and the last 12 months — anchored to the period end (else now), in
real date order. Replaces the cyclical hour-of-day/weekday/day-of-month/month
buckets, which left future days empty and ordered the weekend after Monday.
Backend adds cyclical distributions ByHour (hour-of-day), ByDOW (weekday), ByDOM
(day-of-month) and ByMonthYr (calendar month), all UTC. The Activity-over-time
card gains a selector: Timeline keeps the chronological month trend; Day/Week/
Month/Year show the hour/weekday/day/month distribution as bars.
Adds Stats.ByBandCategory (per band: CW/phone/data counts, band-plan order) via a
modeCategory() bucketing in stats.go, and a StackedBandBars chart in the Stats
panel showing the split per band with a legend.
publishLiveStatus only ran on QSO log or the 15s heartbeat, and the widget polled
every 15s, so an operator's band/freq (and their appearance) could trail by up to
a minute. Now ReportLiveActivity debounce-publishes ~1.5s after a freq/band/mode
change, and the widget polls every 5s (and 1.5s after qso:logged).
The 15s poll effect depended on the dbConn OBJECT, which gets a fresh reference
on several events — each reset the interval before it fired, so the widget could
stay stale for over a minute. Depend on the is-mysql boolean instead, and also
refresh ~2s after qso:logged so our own row appears promptly like the ON AIR
badge.
- Removes the RX-audio CW decoder: deletes app_cw.go + internal/cwdecode, the
cwDecoder/cwPitchHz/cwMu/cwStop App fields, and all frontend state/effects, the
header Ear button, the Tools menu item and the decoded-text strip. The CW
KEYER (WinKeyer/Icom/Flex) is untouched.
- Fix: typing a callsign while a macro is keying now aborts the CURRENT engine
(Flex CWX / Icom / WinKeyer) on the first character, not just WinKeyer during
an auto-call loop — via a shared stopKeyerTx() helper.