The pass-order "#" is a rowIndex valueGetter, but AG-Grid keeps the same row
node across a reorder (getRowId by id) and caches the value, so a moved station
kept its old number. Force-refresh the __order column on every model update in
passOrder mode.
The on-air list was ordered by log time, but a net controller needs the order
the mic goes around. The on-air grid now renders in a controller-owned order:
- A pinned "#" column numbers the round; header sorting is disabled on this
grid (new passOrder prop on RecentQSOsGrid) so a stray click can't reshuffle
it, and any previously-saved sort is stripped on restore.
- ⬆⬇ buttons move the selected station up/down the queue.
- New check-ins append to the end; logged/cancelled stations drop out; the
order is reconciled against the live session list and persisted per net
(localStorage opslog.netOrder.<id>), so a tab switch keeps the round.
- "Log & end" now auto-advances to the NEXT station in pass order.
The whole "Manipulateur CW" settings panel was hardcoded in English, so it
stayed English even with the app in French. Added ~35 wk.* keys (EN + FR) and
wired every label/checkbox/select/placeholder through t(). Also removed the long
serial-engine explanation paragraph as requested.
Reported: on a CQ macro the rig drops to RX between words instead of holding TX
for the whole macro. Root cause is PTT not being held (usePTT off, or the RTS
PTT line not wired/honoured). Improvements:
- "Key PTT line" now defaults ON when the Serial engine is selected — without it
the rig runs on semi-break-in and drops between words.
- The serial keyer's line options (PTT, key line, invert, lead/tail, speed) are
now atomic and live-updatable: SaveWinkeyerSettings -> ApplySerialConfig applies
them from the next character, no reconnect needed.
- Each transmission logs its PTT state / key line / lead/tail, so a rig that
still won't hold TX can be diagnosed from the app log.
The macro itself is sent as one string (not fragmented), so PTT is genuinely
held across word gaps when usePTT is on — pending on-air confirmation via the log.
Opt-in (Settings → General). Shows a "MW #rank" pill next to the DXCC entity
name in the entry-strip band/slot matrix — ClubLog's Most Wanted ranking
(1 = most wanted), personalised to the operator's callsign and refreshed daily.
- internal/clublog/mostwanted.go: fetch mostwanted.php?api=1&callsign=<CALL>
(rank→DXCC JSON, real User-Agent), invert to dxcc→rank, cache to
<dataDir>/clublog_mostwanted.json; NeedsRefresh invalidates on callsign change.
- app.go: keyClublogMostWanted setting, a.clublogMW, startup refresh goroutine,
activeCallsign() helper, and Get/Set/Download bindings mirroring the cty ones.
WorkedBefore now carries MWRank (qso.WorkedBefore.MWRank) when enabled.
- BandSlotGrid.tsx: MW pill next to the entity name, colour-tiered by rank.
- SettingsModal General: toggle + download button + status, mirroring the
ClubLog cty-exceptions block.
Also reorganises the changelog: the theme-persistence fix (landed after the
v0.20.11 tag) plus this feature go under a new 0.20.12 entry; 0.20.11 keeps only
what shipped in its binary.
Some CW interfaces key on the opposite line level (transmit at rest / key
backwards). New "Invert keying (active-LOW)" toggle flips the asserted level for
both the CW and PTT lines, and the idle state drives both lines to their
inactive level accordingly so an active-low rig isn't left keyed at rest.
Default off = N1MM convention (line HIGH = active).
Adds a 4th CW keyer engine alongside K1EL WinKeyer, Icom CI-V and Flex CWX:
OpsLog bit-bangs the Morse itself on a serial control line (DTR keys CW, RTS
keys PTT — swappable), the hardware-keying method N1MM/WSJT use with a Yaesu
SCU-17 and generic interfaces. No WinKeyer chip needed.
- internal/winkeyer/serialcw.go: serialKeyer — worker goroutine, morse table,
WPM + Farnsworth timing (live speed changes), abortable, PTT lead-in/tail/hang.
- winkeyer.Config gains Type ("k1el"|"serial") + CWKeyLine ("dtr"|"rts");
Manager routes Connect/Send/Stop/SetSpeed/Backspace/Disconnect to it.
- app.go: keyWKCWLine setting; WinkeyerConnect sets Type from the engine.
- Settings -> CW Keyer: new "Serial port (DTR=CW/RTS=PTT)" engine with COM port,
key-line selector, speed/Farnsworth/lead-in/tail/PTT. Macros, auto-CQ and
<LOGQSO> reuse the WinKeyer path unchanged.
UNTESTED on hardware (no SCU-17 to hand): polarity assumes N1MM convention
(line HIGH = active). Weight not yet honoured; Farnsworth is.
- Station Control: the amplifier panel is now the exact same card as the FlexRadio panel (extracted shared AmpCard: OPERATE/STANDBY, ON/OFF, power level, output-power bar, live FWD/ID/temp meters). Every configured amp gets its own card — no dropdown.
- Help → "Send log to F4BPO" (only when SMTP is configured): e-mails opslog.log + previous session + crash log to the developer. New email.SendFiles for multi-attachment.
- Bulk edit: new "Frequency (MHz)" field sets freq_hz AND recomputes band; out-of-band values rejected. Fixes a run logged on a stale/default freq after CAT dropped.
- Cluster: Time column sorted lexically on the HHMMZ string, so spots after 0000Z sorted below 2359Z and looked frozen at the UTC rollover. Now sorts by real arrival time.
- Also folds in the DVK auto-CQ/2-column layout and Station Control dashboard batch (changelog 0.20.10, EN+FR).
Multi-amp: Settings->Amplifier becomes a list (amps.json, legacy single-amp keys auto-migrate to entry #1); one client per enabled amp with per-id bindings (GetAmplifiers/SaveAmplifiers/GetAmpStatuses/AmpOperate/AmpPower/AmpPowerLevel/AmpFanMode); legacy a.pgxl/a.spe/a.acom point at the first enabled amp of each family. Amp cards in FlexPanel and Station Control gain a dropdown to pick the amp; the status bar shows one clickable chip per amp. Use case: two SPEs run in parallel.
Flex v4 DSP (8000/Aurora): NRL/ANFL (lms_nr/lms_anf), NRS (speex_nr), NRF (nrf) with level sliders, RNN (rnnoise) and ANFT on/off — keys per the FlexLib slice docs; the section only shows when the radio reports these keys (dsp_v4 flag), so 6000-series panels are unchanged.
The station-control code rebuilt a fresh driver on every status poll and every
relay set. Stateful boards (Denkovi FTDI D2XX, USB-serial) hold an OS handle only
one opener can own, so the first poll opened the board and leaked the handle, and
every poll after failed with 'device in use' — the relays greyed out a second
after Save and auto-control never switched. Drivers are now cached per device and
reused, closed on config change. Adds a Test-connection button + detect feedback
in the device editor (reported by VK4MA).
When the configured amplifier is an SPE Expert (not the PowerGenius), the Flex
panel now shows an SPE control card — the Flex doesn't report SPE amps, so it's
driven by OpsLog's own SPE link. The PowerGenius fan-mode control is hidden when
the amp type isn't PowerGenius.
Day/Week/Month/Year now show the anchor day hour-by-hour, the last 7 days, the
last 30 days, and the last 12 months — anchored to the period end (else now), in
real date order. Replaces the cyclical hour-of-day/weekday/day-of-month/month
buckets, which left future days empty and ordered the weekend after Monday.
Backend adds cyclical distributions ByHour (hour-of-day), ByDOW (weekday), ByDOM
(day-of-month) and ByMonthYr (calendar month), all UTC. The Activity-over-time
card gains a selector: Timeline keeps the chronological month trend; Day/Week/
Month/Year show the hour/weekday/day/month distribution as bars.
Adds Stats.ByBandCategory (per band: CW/phone/data counts, band-plan order) via a
modeCategory() bucketing in stats.go, and a StackedBandBars chart in the Stats
panel showing the split per band with a legend.
Implements the SPE Application Programmer's Guide protocol: packets
0x55 0x55 0x55|CNT|DATA|CHK (sum%256), OPERATE key 0x0D (toggles STANDBY/OPERATE)
and STATUS request 0x90 whose 0xAA-framed reply is a 19-field CSV (mode, RX/TX,
band, power level, output W, SWR, V/I, temp, warnings, alarms). internal/spe
polls status ~1/s over USB serial (go.bug.st/serial, 8N1) or TCP (RS232-to-
Ethernet bridge) — same codec, different transport.
Wired via startPGXL (starts the SPE client for spe* types), bindings GetSPEStatus
/ SPESetOperate, and a live status card + OPERATE/STANDBY toggle in the Amplifier
settings panel. Only the two example-anchored commands are sent (safe); other
keystroke codes were ambiguous in the guide's table. Untested on hardware.
Renames the Hardware section to Amplifier and adds an amplifier-type selector
(4O3A PowerGenius XL, SPE Expert 1.3K-FA / 1.5K-FA / 2K-FA) plus a transport
choice for the SPE amps: USB (serial COM + baud) or Network (RS232-to-Ethernet
IP:port). PGXLSettings gains Type/Transport/ComPort/Baud (keys keep the pgxl.*
prefix for back-compat). PowerGenius still drives over TCP; SPE settings are
stored but control is not wired yet (needs the SPE serial protocol).
- Denkovi (FT245 D2XX) now selectable as 4 or 8 relays (a 4-relay board just uses
the low nibble); NewDenkovi takes a count, driven by the device's Channels.
- New 'usbrelay' backend: cheap CH340/LCUS USB-serial boards over a COM port
using the common A0 protocol ([0xA0][relay][state][checksum]); write-only, so
Status is a shadow. Channel count configurable (1/2/4/8/16).
- StationDevice gains Channels; deviceRelayCount() drives label/relay counts for
the variable-size types. Device editor: channel selector + COM-port picker
(usbrelay) / FTDI-serial (denkovi).
Both untested on hardware; the A0 command set / Denkovi bit order may need a tweak
after a live test.
Third relay device alongside WebSwitch and KMTronic. Despite enumerating as a
COM port, this board is driven via FTDI D2XX synchronous bit-bang (one byte = 8
relays, bit 0 = relay 1), not serial ASCII — so we load ftd2xx.dll at runtime
(no CGO) and call FT_OpenEx/FT_SetBitMode/FT_Write, addressing the board by its
FTDI serial (e.g. DAE0006K), exactly like the vendor tool. Windows-only (stub
elsewhere); ListDenkoviDevices enumerates connected serials for the picker.
Wired into relaydev (Count/Status/Set), app.go (deviceDriver/relayCountFor/type
whitelist + ListDenkoviDevices binding), and the Station device editor (new type
+ FTDI-serial field with Detect). Untested on hardware; bit order / on-polarity
may need a flip after a live test.
PortBtn was defined inside AntGeniusPanel, so every render produced a new
component type and React unmounted/remounted every port button. Normally
re-renders are rare so it's invisible, but the CW decoder floods the app with
cw:text/cw:status events (re-render many times a second), tearing the buttons
down between mousedown and mouseup — the click never completed and the antenna
never switched. Move PortBtn to module scope (stable identity) and pass
onActivate/t as props.
Adds a Rename button to Settings -> Database: renames the current SQLite database
(e.g. opslog.db -> F4BPO.db) while preserving every setting/profile, unlike New
database which starts empty. Implemented as a VACUUM INTO copy + pointer switch;
the old file (open and locked now) is scheduled via config.json delete_pending
and removed, with its -wal/-shm sidecars, on the next launch.
Adds ExportAwardForCatalog(code, version): writes the selected award as a
catalog-format JSON ({"def":…,"references":…}) stamped with a version and with
user_edited cleared, ready to paste over internal/award/catalog/<code>.json. A
new release then propagates the change to the whole team via mergeCatalog —
unedited copies auto-upgrade, edited ones are offered the update.
UI: a version input + "Publish to catalog…" button in the award editor footer,
defaulting to one past the award's current version.
Live status: when an operator goes offline (no QSO in the window) OpsLog now
DELETEs its live_status row instead of just flipping online=0, so a status page
that lists present/recent rows shows them as gone without having to read the
online column — the whole point of the feature. The row reappears on the next
QSO.
Recent QSOs columns: toggling an award column (e.g. DDFM) rebuilt columnDefs and
made AG Grid re-apply every colDef hide default, so hidden non-award columns
(QTH/Grid) came back and restoringRef stayed stuck true (saving off). The
restore-saved-state effect now also runs on awardShown changes, so the other
columns keep the user's visibility.
Rate meter: on a shared MySQL logbook it now shows two lines — OP (the active
operator, accent) and Team (all operators, foreground) — each with the 10/60-min
QSOs/hour; single-op keeps the one-line display.
Live-stations widget: only stations currently on air are listed (offline ones
are hidden rather than greyed).
Recent QSOs footer: 'Showing X of Y' now reflects the AG-Grid COLUMN filters
(the funnel icons) — the grid reports its displayed row count, so filtering a
column shows how many QSOs remain instead of always the full total.
The RST comboboxes allowed free text, so a report typed by hand that isn't in
the mode's list (e.g. "600") was committed. Drop allowFreeText on the four RST
fields (QSO entry + edit modal) and make commit-on-type push a value only when
it's actually in the list; a leftover invalid entry reverts to the last valid
value on blur. Programmatically filled values (FT8 SNR over UDP, presets) are
unaffected — only manual typing is constrained.
Headline KPI tiles are now tinted cards: a soft colour wash, a corner glow and
a left accent bar, each tile its own hue (QSOs blue, calls teal, DXCC violet,
continents orange, confirmed green) — the number itself stays in foreground ink
for full contrast on every theme. Chart cards gain a soft shadow and a coloured
dot in the header matching the section.
Charts are no longer all-blue: BY MODE colours each bar by the categorical
palette (modes are real categories, like the continents donut), and the other
horizontal-bar charts take their card's accent (top entities green, operators
violet, stations orange) instead of a single blue. Single-hue-per-series
discipline is kept; only genuine categories get per-bar colour.
Automatically switches the Station Control relay boards from the rig's
current frequency / band. Each relay carries one rule: off (manual), a
frequency window (ON inside [lo,hi] kHz, OFF outside), or a set of bands
(ON on those bands, OFF elsewhere). Evaluated on every CAT frequency/band
change; a relay is only switched when its desired state actually changed,
so tuning within a range doesn't hammer the board.
A cached atomic flag keeps the CAT hot path a no-op when the feature is off
(important during FT8 slice churn). Saving re-applies from the live
frequency so a changed rule takes effect immediately.
New Settings → Hardware → Relay auto-control section: master enable plus a
per-relay mode (Off / Frequency / Band) with kHz range inputs or band
chips, per configured relay board. i18n EN + FR. Azimuth/Time modes (the
other two PstRotator tabs) are left for later.
PANELS[selected]() invokes each settings panel as a plain function, so a panel
must not call hooks. ADIFMonitorPanel uses useState/useEffect/useI18n, which
broke the Rules of Hooks and blanked the section. Render it through JSX
(() => <ADIFMonitorPanel />) so it mounts as a real component with its own
hook context — same pattern as the Flex panel.
Watches a configurable list of external ADIF files (fldigi RTTY logbook,
N1MM, VarAC…) and imports newly appended QSOs automatically. Each record
goes through the existing UDP-log path, so it gets full enrichment, ±2-minute
dedup (shared udpLogMu, can't race the UDP auto-log) and automatic upload to
the configured external services — no per-file toggles like Log4OM.
A newly added file starts at its current size (offset -1 sentinel → size on
first scan), so the QSOs already in it are NOT bulk-imported; only contacts
logged after it was added come in. Reads only up to the last complete <eor>
so a half-written record waits. Handles truncation/rotation (re-reads from 0,
dedup protects) and persists per-file offsets without clobbering a concurrent
UI edit of the file list.
New Settings → ADIF monitor section: master enable + add/remove/toggle files.
Backend emits adifmon:imported → the grid refreshes and a toast reports the
count. i18n EN + FR.
Opt-in via Settings→General (portable pref opslog.showQsoRate). Shows the
contest-style QSO rate in QSOs/hour, projected from the trailing 10-minute
(count ×6) and 60-minute windows, between the widget icons and propagation.
Backend: qso.RecentRate counts QSOs whose start time falls in each trailing
window, scanning only the last 400 rows (cheap on a large log); App.GetQSORate
exposes the 10/60-min counts. Frontend refreshes on qso:logged and a 30s tick.
The meter shares the propagation grid cell — the header is a fixed 6-column
grid, so adding it as its own child pushed profile/band-map/compact onto a
second row. i18n EN + FR.
theme: self-heal the persisted theme after mount. The synchronous boot
read only looks at localStorage, which is empty when the WebView cleared
its storage or when syncPortablePrefs ran before the backend wired its
settings store (GetUIPref returned "" with no error) — so a restart could
silently land on the default light theme. ThemeProvider now re-reads the
portable pref from the DB once the backend is up (retrying briefly to ride
out a slow startup) and applies it, without clobbering a manual pick.
ClusterGrid: the Call cell now uses a danger pill for NEW DXCC, consistent
with the NEW BAND / NEW MODE pills, instead of a full-cell red fill. cellChip
inherits the column's font size (no fixed 9px / height) so a pill around a
callsign stays the same size as the plain callsigns beside it.
DvkPanel: the voice-keyer TX indicator (LED + label) is red while
transmitting, not orange.