rouggy 7d7d175ede feat: SPE amp ON/OFF buttons and Low/Mid/High power-level control (keystroke codes best-guess from APG, pending hw verification) 2026-07-21 01:25:55 +02:00
rouggy be1ae76eb3 fix: correct SPE band-code map (00=160m,01=80m,02=60m...confirmed on hw); add output-power bar to SPE amp card 2026-07-21 01:19:24 +02:00
rouggy fe1a77a54d fix: use official SPE band-code table from the manual (00=60m,01=160m,...) 2026-07-21 01:10:12 +02:00
rouggy b818a2d947 fix: correct SPE status CSV field alignment (leading empty field shifts indices +1); decode band code; OPERATE/STANDBY now reflects real amp state 2026-07-21 01:09:13 +02:00
rouggy 42a6b9c76a debug: log raw SPE status frame on change (to verify CSV field alignment on real hw) 2026-07-21 00:54:13 +02:00
rouggy 2e39615554 feat: SPE Expert amplifier control (serial/TCP) — OPERATE toggle + live status
Implements the SPE Application Programmer's Guide protocol: packets
0x55 0x55 0x55|CNT|DATA|CHK (sum%256), OPERATE key 0x0D (toggles STANDBY/OPERATE)
and STATUS request 0x90 whose 0xAA-framed reply is a 19-field CSV (mode, RX/TX,
band, power level, output W, SWR, V/I, temp, warnings, alarms). internal/spe
polls status ~1/s over USB serial (go.bug.st/serial, 8N1) or TCP (RS232-to-
Ethernet bridge) — same codec, different transport.

Wired via startPGXL (starts the SPE client for spe* types), bindings GetSPEStatus
/ SPESetOperate, and a live status card + OPERATE/STANDBY toggle in the Amplifier
settings panel. Only the two example-anchored commands are sent (safe); other
keystroke codes were ambiguous in the guide's table. Untested on hardware.
2026-07-20 17:59:24 +02:00