Adding it to the device lists put it in all four dropdowns, and an
operator picked it as their RECORDING MIC — which would have recorded the
station they were listening to instead of their own voice, on every voice
message and every QSO recording. It is not a microphone, and it is not a
pair of speakers either: the audio going the other way is transmit audio.
So it is listed for 'From radio' and 'To radio', and taken out of the mic
and the listening dropdowns.
And the RX monitor is disabled when the radio IS the source, with a line
saying why: the TCI stream is pushed into the QSO recorder, and nothing
plays it to the speakers. The button was there, enabled, doing nothing
audible — which is worse than a button that says it cannot.
TCI already carries the frequency, the mode, the meters and now the audio.
It also carries everything else about the radio — and OpsLog was logging
most of it once as '(unhandled once)' and throwing it away. The console is
mostly a place to put what was already arriving.
That makes it the cheapest panel here, and it is worth saying why. A K3
console costs a command and a reply for every value it shows, which is why
it reads its settings in a rotation and its meters only while on screen.
TCI PUSHES: the radio announces its drive, its filters, its noise blanker
and the rest on connect, and again whenever any of them changes —
including when the operator changes them in ExpertSDR3's own window, which
this panel therefore follows without asking anything.
What it drives: drive and tune drive, mic gain, TUNE, volume, mute,
squelch and its threshold, NB, NR, ANF, APF, AGC speed, the passband, RIT
and XIT with their offsets, and the VFO lock. The S-meter is a real dBm
reading, so its S units are arithmetic rather than the calibration guess a
K3's meter needs.
Setters never update the cached state. The radio answers with the new
value, and taking its word is what keeps the panel honest when a setting
is refused, clamped, or changed at the radio a second later — the one
exception being a slider mid-drag, held for 900 ms so it is not dragged
back by its own echo.
Capped width and centred, like the other consoles. Also offered as a
docked pane — and the Elecraft console is offered there too now: App has
always had that pane, Settings simply never listed it.
Reported on an Ultrabeam over USB: the port could not be chosen from the
dropdown, and the panel would not scroll.
That field was a Combobox — a list you can also type into — chosen so the
port of an adapter currently UNPLUGGED could still be configured. It is
now the same Select every other serial device in OpsLog uses, the one that
demonstrably works. The case it was built for is kept differently: a
configured port that is no longer detected is added to the list, so it
stays selected and visible instead of vanishing when the adapter is out.
Also hardened the Test button's guard, which called .trim() straight on
the port and the host. A settings object without them — an older build, a
save that landed short — throws there DURING RENDER, and a panel that
throws while rendering is exactly a panel with a dead dropdown that will
not scroll. Whether or not that is what this operator hit, it is a way to
produce both symptoms at once and it costs nothing to remove.
Telling somebody's amplifier where to be is a write to their station, and
it now has a switch — the SAME switch an Acom uses. 'Keep the amplifier on
the radio's band' is one idea to an operator; that it needs a second
serial port and a rig emulator on one amplifier and a single ^BN on
another is our business, not a reason for two checkboxes.
On by default for a KPA, because an amplifier left on the wrong band is
the worse outcome of the two, and the operator who has wired it straight
to the radio turns it off once. The hint says exactly that case, since it
is the only one where a second voice telling the amplifier where to be is
unwelcome.
Two things the wiring got wrong, both visible on screen.
A KPA fell through to the PowerGenius branch of the amplifier card and was
drawn as one — titled 'POWERGENIUSXL · ELECRAFT KPA1500', with a
PowerGenius's meters and none of its own. It has a card now: OPERATE, ON
and OFF, band, power, SWR, temperature, supply, and the fault across the
end. The OPERATE button carries a tooltip saying it also clears the fault,
because that is the button an operator already has under the cursor when
they need it.
And the band-follow option was offered on it. That option exists because
an Acom POLLS a transceiver and has no command to be given a band, so
following it needs a second serial port and a rig emulator answering those
polls. The KPA has ^BN — OpsLog simply tells it, on the link it is already
using, and only when the band CHANGES. The option is gone from the KPA and
the telling is automatic.
Also: Acom rather than ACOM everywhere it is read, which is how the
company writes it. Identifiers, package names and log lines are left
alone — renaming those is churn with no reader.
Wired into the multi-amplifier support that already carries the SPE, the
ACOM and the PowerGenius: a fourth brand rather than a fourth mechanism.
The linking, the fan-out and the poll all work on it unchanged.
Three things the KPA does differently, and each is handled where it shows
rather than explained in a hint:
- A KPA500 has no network side at all. Choosing it puts the entry on
serial, and a configuration still asking for TCP is refused with a
line saying so instead of retrying an address that cannot answer.
- The amplifier answers ^ON while its main supplies are OFF — a sleeping
microcontroller stays awake for exactly that — so power-on stays
available over the network, unlike the SPE and ACOM which need their
serial control lines.
- Going to OPERATE clears the current fault, everything except
temperature. The widget says so under the fault, because the button
that fixes it is the one already on screen.
Defaults that leave a working configuration when the model is changed:
38400 baud, TCP port 1500, and a full-scale power mark of 500 or 1500 W
by model — a KPA500 read against a 1500 W scale looks idle at full
output.
Two faults, and the first was a design mistake of mine.
The choice was written only as the award override, to keep the imported
CNTY as a record of what HAMLOG said. But CNTY is what the comparison
READS, so the contact went on disagreeing for ever: settle a hundred
rows, run the comparison again, get the same hundred back. The reasoning
was about preserving evidence; the effect was a button with no visible
consequence anywhere, which is indistinguishable from one that does
nothing. This is the operator's own log, and correcting a field in it is
the point of the exercise. The district now lands in CNTY as well as in
the award reference.
And the settled rows stayed on screen, which made the same button look
broken a second time. They are dropped as they are applied — locally,
rather than by re-running the comparison, which reads the whole log and
would be seconds of silence on a remote database to be told what is
already known. The agree/disagree counters follow.
The comparison could show two hundred contacts where the log and the
database name different districts, and leave the operator with nothing to
do about any of them but open each QSO and edit it by hand.
Now each row carries the two values as buttons: click the district you
keep, then apply. There are shortcuts for keeping one source everywhere,
and applying is a separate act — clicking through two hundred rows with
each one written as it is clicked would make a slip permanent before the
reading was finished.
The choice is written as the contact's AWARD REFERENCE, not over the
imported CNTY, and that distinction is the point. CNTY is what the
downloaded log said; overwriting it would destroy the evidence the
comparison runs on, and the next comparison would agree with itself and
prove nothing. The override is the operator's decision, it is what the
award engine counts, and it beats both sources. So the log keeps saying
what it said, the database keeps saying what it says, and the contact
counts for the district that was chosen.
The buttons show the districts themselves rather than a tick box: someone
arbitrating between RO-19 and KO-05 should be picking a value they can
read, not remembering which source a checked box stood for.
The TCI section of the audio settings was an investigation: open the
stream, read what arrives, record ten seconds to listen to, key a tone.
It answered every question it was built for — the frame layout, the
sample width, that the radio asks rather than follows a clock, that the
transmit audio source decides — and confirmed 80 W on real hardware.
None of that belongs in front of an operator now. The radio is simply one
of the devices in the two dropdowns, and choosing it IS the configuration:
one control, in the place where the question is already being asked.
Keeping the tick box beside it would have been two switches for one
decision, with the second one where nobody looks.
Gone with it: the stream/record/probe bindings, the audio.tci_rx setting,
and twenty-four translation keys. The plumbing they proved out stays and
now carries the voice keyer.
A SunSDR carries its audio on the same WebSocket as its commands, so
OpsLog can take it directly: no virtual cable, no second sound card, no
Windows mixer between the recording and the air. The radio appears as a
device in both audio lists and can be chosen for either direction.
Everything here was settled on real hardware over one evening, and none of
it was guessable from the documentation:
- The receive stream answers format=3 for four-byte floats, so the
sample width is derived from the frame rather than trusted from the
field.
- The radio asks for transmit audio only when the transmission is the
CLIENT'S, and only when its transmit audio source is TCI rather than
the microphone.
- The chrono is a REQUEST, not a clock: no payload, carrying the size it
wants, 47 times a second. Audio goes out in answer to it and never on
a timer of our own — a timer was the first attempt and all 234 frames
of it were ignored.
Confirmed: a clean test recording, and 80 W out of a 1 kHz tone.
A first real transmission settled one question and raised a better one.
With the receive stream open and six seconds of transmit, the radio sent
282 frames of receive audio and NOTHING else: no chrono, no transmit
audio. So the chrono the documentation describes is not offered to a
client that merely happens to be connected while the operator keys the
microphone, and waiting for it to appear is waiting for nothing.
The reading that fits is that the radio asks for audio when the
transmission is the CLIENT'S and takes the microphone when it is the
operator's — which makes the experiment obvious. Key it from here, push a
1 kHz tone, and watch. Chrono frames appearing gives their size and
cadence by measurement instead of by guesswork; no chrono but a tone on
the meter is just as useful, because then the pacing is optional and the
voice keyer can push frames at the rate the stream already runs at.
A tone rather than silence so the answer shows on the power meter and not
only in the log.
It transmits, so: an explicit button inside a warning box, five seconds,
capped at ten, and every path out unkeys — including the panic that has
not happened yet and a socket that dies mid-tone. A transmitter left keyed
by a defect is the one fault here that would reach somebody else's band.
Writes are now serialised too. send() held the lock only long enough to
read the connection, which was enough while every command came from the
poll loop; a stream of audio frames from a second goroutine is not, and
gorilla panics on a concurrent write rather than failing quietly.
Two faults, one behind the other.
RDAPanel is nested inside SettingsModal so it can read its state, and it
was written as <RDAPanel />. A nested function is a new component TYPE on
every render: React cannot know it is the same panel, so it unmounted the
tree and mounted a fresh one — and a fresh scroll container starts at the
top. It is called now, like the other panels, which produces the same
elements in place and never disturbs the scroll position.
What it was reacting to should not have reached it either. The PSK
Reporter and grid-cache poll ran every three seconds from wherever you
were in Preferences, re-rendering the whole dialog for a count shown only
on the cluster section. It now runs while that section is open, and the
one-time loads it was sharing an effect with have stayed where they were
rather than refetching on every click in the sidebar.
The visible result: a hundred contacts to correct can be read from top to
bottom.
Confirmed on a real SunSDR: the stream decodes and the test recording
plays back clean. So it can do the job a virtual audio cable was doing —
this wires it to the QSO recorder, which already accepts a pushed source
(the Icom network audio uses the same door).
The conversion lives here rather than in internal/cat: the radio's job is
to hand over what it sent, not to know that the recorder works in 16 kHz
mono. Three samples are AVERAGED rather than two of them dropped —
decimating by picking every third folds everything above 8 kHz back into
the voice band, and on a receiver that is hiss, which a QSO recording has
plenty of already.
Off by default, and applied the moment it is switched: it replaces a
sound card the operator has already wired up, and an option that needs a
restart to take effect reads as an option that does not work.
TWO FAULTS, ONE SYMPTOM — 'it refreshes ten times a second and the
buttons cannot be pressed'.
Preferences is a child of the main view, so every cluster spot, CAT push
and decode re-rendered the entire panel. On a busy evening that is
several times a second, and the panel is large enough that the rebuild
outlasts the gap between them: buttons missed their clicks because the
element under the pointer was replaced between the press and the release.
It is memoised now, and the callbacks App hands it hold their identity —
without that the memo compares unequal every time and buys nothing.
The dropdown menu was an absolutely-positioned child, so it was clipped
by whichever scrolling or overflow-hidden box it sat in: the satellite
list showed one entry of eight. It is portalled to the body now,
positioned from the field's rectangle, re-measured while open, and opens
upward when the field is near the bottom of the screen — which is exactly
where these fields tend to be.
SATELLITES: the field read the list once, when the details panel first
mounted — which is at startup. A list saved in Preferences afterwards
therefore did nothing until a restart. It comes from App now, which
already reloads the lists when Preferences close.
RDA COMPARE: a failed comparison wrote its error into the message beside
the FILL DISTRICTS button, a row above — the error appeared under a
button nobody had pressed while the one that had been pressed showed
nothing, which reads as 'the button does nothing'. It has its own message
now, and reports the two results that look like silence: no disagreement
at all, and no Russian contacts to compare. Both buttons say what they
are doing while they do it, and the comparison logs before it starts
reading — on a remote MySQL that read is seconds of quiet.
overscroll-contain on the conflict box stops the wheel from chaining to
the pane behind it. With a short list — nothing to scroll inside the box
— the pointer over the table therefore froze the whole panel: the page
would not move and neither would the list.
The box scrolls when it has something to scroll; the page scrolls the
rest of the time, which is what containment was preventing.
Save builds the lists payload field by field, and the new list was not
among them — so every Save wrote an empty satellites array over whatever
had just been typed.
Normalised in the save as well as on the field's blur: the Save button is
reachable without ever leaving the box, and a list whose survival depends
on where the cursor went first is a list that saves sometimes.
SAT_NAME is compared character for character by the awards and by LoTW:
AO-91 and AO91 are two different satellites to everything downstream, and
typing it afresh on every pass is how one of them ends up in a log. So
the station keeps its own list (Preferences → Lists → Satellites) and the
field offers it, alphabetically — while still accepting anything typed,
because a bird worked once and never added to the list must not be
impossible to log.
Not seeded with a shipped list of two dozen birds: an empty list means
this station does not work satellites, and filling the dropdown with
names nobody here has heard makes the field harder to use, not easier.
Also fixes the RDA district comparison: its conflict list was capped at
about six visible rows of a list holding up to two hundred, in a panel
that would not scroll to show the rest, and nothing in it could be acted
on. Taller, scrolling, and a callsign opens the contact.
Three wide buttons for something most radios cannot vary was noise, and
they pushed the fields below into whichever grid column came next — the
panel looked shuffled.
Now: a dropdown, shown only when the brand has more than one way in. A
Yaesu is reached over USB and that is the end of it; a control offering
one entry that cannot be changed is a decision that is not one.
Brands: OmniRig first — it is the one that works with any radio, so it is
where someone who cannot find their rig should land — then alphabetical.
Kenwood and Elecraft drop the proprietary-network entry: neither is
implemented and neither is planned, and naming a road that goes nowhere
is only useful when someone might reasonably look for it.
The standalone checkboxes (protocol log, DTR/RTS) take a full row instead
of half of one, which is what was breaking the alignment.
The backend list mixed two different questions. 'Icom (USB)' and 'Icom
(network)' were separate entries; Kenwood and Elecraft hid the same
choice in a field further down; and Flex, TCI and OmniRig sat in the same
list as if they were the same kind of answer. An operator picks a radio
and then says how it is plugged in, so that is what the panel asks, in
that order, and the two answers together choose the backend.
Each brand offers only the connections it has, and a brand with one way
in still shows it, greyed: 'there is no choice here' is an answer and an
empty space is not. The stored backend names are unchanged — 'icom-net'
is still 'icom-net' — so a settings file written by an older build keeps
working, and brand+connection are DERIVED from it rather than held
alongside it, which is what keeps them from drifting apart when something
else writes the backend.
USB, RS-232-to-Ethernet, and the radio's own network protocol are three
different things, so they are three entries in one dropdown — and the
transport is now a stored setting rather than something deduced from
which field happened to be filled in. The old rule (a host wins whenever
it is not empty) is invisible from the settings page: someone who typed a
host months ago and later set a COM port had a radio that never answered
and nothing on screen to say why.
The third entry is named and refused, with the reason. It is a session
with its own framing and login, not the CAT byte stream over a socket, so
it has to be written per radio and against one — and a K4 owner reading
this list should be told that, not left wondering whether the empty
address field was the problem.
The upgrade reads an older install from what it has: a configured host
means the bridge, which is what the previous code used it for. Pinned by
a test, including the case that matters after the fact — choosing USB
with a stale host still stored gives the COM port.
The network option IS implemented — the same ASCII CAT over TCP instead
of a cable, for a ser2net bridge, an Ethernet-serial adapter, or a radio
exposing its raw CAT port. What was wrong is how it was offered: the COM
port and the network address sat side by side with nothing to say that
the address wins whenever it is not empty.
Worse, the example address read 192.168.1.50:4532. That is Hamlib
rigctld's port — a different protocol, and the one OpsLog SERVES under
'Share CAT'. Anyone copying the example was pointing the radio link at
OpsLog's own server.
Now one choice, then the fields that belong to it. And when the far end
answers something that is not the radio's CAT, the error says that rather
than 'check the baud rate', which over TCP is advice about a setting that
cannot be the cause.
A station with a switch knows something the log does not: which antenna
is actually connected. The working conditions hold what was PLANNED for
the band, and stay right until the operator throws the switch — after
which every QSO keeps claiming the other antenna.
Optional, and off by default: a station that names its antennas
differently in the two places would otherwise find its log quietly
rewritten. The name written is the one configured on the device, since
that is the name the operator gave it and the one they will look for.
WHICH PORT is the real problem, and the reason this is not a one-liner.
The switch has two, the radio has two jacks, and the QSO went out through
one of them; naming the wrong port's antenna is worse than naming the
band default, because it looks authoritative. The radio's own TX antenna
selection decides, and the jack-to-port wiring is a setting — it is the
station's cabling and neither device can report it.
When the port cannot be told — a transverter jack, a rig that reports
nothing, both switch ports live — nothing is written and the band default
stands. Silence beats a confident guess in a field nobody re-checks.
The SunSDR announces its own stream at connect —
audio_stream_sample_type:float32 and audio_stream_channels:2 — and both
were being logged as unhandled while the code worked the format out from
frame arithmetic. The declaration is better evidence and arrives before
the first frame; the arithmetic stays as the check on it. The channel
count now drives the mix-down instead of an assumed stereo.
Adds a ten-second test recording, written as a WAV beside the QSO
recordings. Counting frames proves a socket is delivering bytes; it says
nothing about whether those bytes are the receiver's audio, at the right
rate, in the right order. A stream decoded with the width wrong or the
samples misaligned counts exactly as well as a correct one and sounds
like a fan — so the test is a file the operator can play, the same way
the CW decoder was settled on the air rather than on a spectrogram.
The file is written at the rate the RADIO reported, not a constant: a
recording at the wrong rate plays at the wrong speed, which is the one
fault that would be blamed on the decoding.
Two things reported together, both about a list that fights back.
The GRID froze nothing: every spot landed at the top and pushed the rest
down, so a few rows in, the callsign under the pointer had moved by the
time the click arrived. It now stops redrawing as soon as it is scrolled
away from the top and says how many spots are waiting; reaching the top
again, or clicking the notice, releases it. The arrivals are counted by
finding the frozen top row in the live list rather than by comparing
lengths — the list is a ring buffer, so once it is full a length
comparison would report nothing new for the rest of the evening.
The COMMAND BUTTONS were capped at 120 characters. A DXSpider filter
naming the prefixes an operator wants runs well past that, and the field
just stopped accepting keystrokes: the command was saved truncated with
nothing to say why. 500 now, with the full text in the tooltip since the
box cannot show it.
A SunSDR already carries its receive audio on the same WebSocket as its
commands, so a virtual audio cable and a second sound card are two pieces
of plumbing an operator installs for no reason. This is the receive half:
what the QSO recorder and the CW decoder need.
The reader now looks at the frame type. It used to ignore it and split
every frame on ';' -- harmless only for as long as no stream was ever
opened, since audio bytes would otherwise have been handed to the command
parser a hundred times a second.
NOTHING HERE IS CONFIRMED ON A RADIO. The header layout comes from the
TCI documentation, and the stream-type numbers are exactly the sort of
detail a document gets right and a memory of it does not -- so the first
forty frames of a session are logged verbatim, and a test bench in
Preferences > Audio reports the sample rate the radio chose, the frames
arriving and the peak level of the last second. 'The stream is open' and
'audio is arriving' are different claims and only the second is worth
anything to whoever tries this first.
Transmit (the voice keyer) is the other half and is deliberately absent:
it has to answer the radio's chrono packets at the right pace, and that
is worth doing once the format is settled on real hardware.
The list is a ring buffer that held a thousand spots, and on a busy
evening a thousand arrive in a couple of minutes. So the buffer decided
how long a spot lived, and the spot LIFETIME setting never got the chance
to expire anything: fifteen minutes meant nothing when the oldest spot
was pushed out after two.
Now settable (Preferences → Cluster, beside the lifetime, since between
them they decide the same thing), 100 to 10 000. The ceiling is a real
limit rather than a round number: every spot is matched against the
worked index and the alert rules, and is a row the cluster grid and every
open band map re-render.
Withdrawing auto-call added a runtime guard and removed every control.
The stored preference was left alone, so 'enabled: true' still sits in
localStorage on the machines that had it on -- and any build without the
guard reads it and keys the transmitter for a feature that no longer has
a switch anywhere in the interface.
loadAutoCall now switches it off and writes it back the first time it
reads it, so the disarming survives a downgrade or a reinstall. Also
drops the dead auto-call state left behind in the settings modal.
A withdrawn feature that keys a radio has to be disarmed where it is
remembered, not only where it runs.
A log imported from HAMLOG.online carries the Russian district in CNTY, and the
offline RDA database has its own answer for the same contact. Which wins is a
real question — but only if the two are independent. If HAMLOG's value is itself
a lookup in the same kind of database, there is nothing to arbitrate and a
precedence rule would be ceremony around a redundancy.
So this measures instead of deciding: Settings → RDA gains a read-only compare
that reports agreements, disagreements, and the contacts where only one side
knows, then lists the disagreements — callsign, date, both districts, whether
the database answer was a DATED record (the award administrators' own fact) or
the callsign's current district (an assumption), and whether the QSO is
confirmed on HAMLOG (their value has then been through a match of two logs).
It changes nothing in the log. What to do about a conflict is the next decision,
and it should be taken with the operator's own numbers in hand.
Also: the four HAMLOG fields become filterable, so 'never sent there' is a
filter rather than a guess. A field that can be written and not read back is
half a feature — pinned by a test against the bulk-editable list.
Preferences → Confirmations gains a HAMLOG.online row, sent and received, with
the same defaults every other service has: a new QSO can start at N so the
backlog is meaningful from the first contact. The defaults reach it through a
new setExtraDefault — fill() writes through a pointer to a string field and
these two live in the extras map, which no pointer reaches.
The QSO grid gains four HAMLOG columns (status and date, both directions),
hidden by default: a column per service shown to everyone is how a grid becomes
unreadable.
And the paragraph explaining what "Sent" means is gone from that page.
HAMLOG.online is now reachable: Settings → External services → HAMLOG.ONLINE
takes the API key, the auto-upload switch and the timing, exactly like the six
services beside it, and a link opens the page where the key is issued.
The button next to it checks the KEY, not the connection. HAMLOG answers
KEYSTATUS with the callsign the key belongs to — something no other service
here offers — so the result reads "Key is valid — account F4BPO" rather than a
green tick. A key pasted from a club account or a second station is visible at
once, which is precisely the mistake a tick would have hidden.
No on-close timing, for the same reason as Cloudlog: there is no per-QSO upload
column to select a backlog from at shutdown, so the option would have done
nothing. Immediate or delayed, and a stored on_close falls back to immediate
rather than silently uploading nothing.
The appearance rules gain a HAMLOG.online channel too, so a row can be coloured
"confirmed" on that alone. It reads the ADIF extras — the standard names a field
for hamlog.EU and none for hamlog.ONLINE — using the same keys the award engine
reads, so the two can never disagree about what a confirmation is. "To send"
skips it: a QSO is either uploaded or not, there is no card to be owed.
Panadapter spots are now worth reading. The comment carries the spotter, the
entity and the status in DXHunter's own shape — "CQ up 2 [F4BPO] [Franz Josef
Land] [New Slot]" — which needed two things nothing documents: SmartSDR splits
its command line on SPACES, so the words ran together until every space became
non-breaking; and it truncates past ~60 characters, so the cluster's own words
are trimmed first and the three brackets always survive. RBN column padding is
collapsed on the way in, or a preserved run of spaces opened a gap wide enough
to push the rest off screen.
"Already worked" means the CALLSIGN is in the log, not the entity: saying it of
a station never contacted was simply wrong. Each status can also be kept off the
panadapter entirely, and the WSJT-X decode spots obey the same switches — the
palette governs the panadapter, not one of the two things that feed it.
And the radio is no longer hammered: a spot whose frequency, colour and comment
are unchanged is not removed and redrawn. A busy skimmer feed re-spots the same
station every few seconds; one two-minute session sent 2128 adds, 88 of them for
a single callsign, and the display did not move a pixel for any of them.
CI-V, from an IC-7850 that kept killing JTDX: a reply the rig sent to another
controller on the same bus is no longer taken for ours, and a set_ptt, set_freq
or set_mode whose acknowledgement goes missing is verified by reading the rig
back instead of being reported as a failure. WSJT-X and JTDX answer a failed
command with a Rig Control Error and drop the link mid-over — 98 keyings, 6 lost
acknowledgements, 2 dropped connections in one session. The check waits 700 ms,
not the poll's 150: the rig has just failed to answer twice because it was
retuning, and a short probe would fail for the same reason.
Auto-call is withdrawn — it duplicated DXHunter, which already answers decodes,
and two programs deciding that from one shack key over each other. The library
is kept whole and dormant; a guard in App.tsx makes sure a stored preference
cannot key a transmitter whose switch no longer exists.
Also:
- the log rotates while running, not only at startup: the CI-V trace left on
wrote 416 MB and nothing would have stopped it before the disk did. Closing
it now releases the crash file too — the runtime keeps its own duplicate.
- the interface zoom announces itself, with a badge, a click back to 100% and
a View menu; Ctrl+wheel and Ctrl+0 always worked and nothing said so.
- no more elastic bounce, and no swipe-to-navigate out of the app.
- Edit QSO: your own TX power and the contacted station's extended locator
were saved and written back with no box to set them.
- FT decodes: continents are a multiple choice; a compound MSHV message that
answers two stations in one line is recognised as addressed to you.
Ultrabeam on a serial port never worked, and three faults were stacked so
each hid the next:
- Stop() did not wait for the poll loop, so a stopped client kept the COM
port. Every later client then failed with "Serial port busy" — the
program holding it being OpsLog itself.
- startUltrabeam tore the old client down CONCURRENTLY with starting the
new one, and "Test connection" built a second client on a port already
ours. Harmless over TCP, fatal on a port with one owner.
- A silent serial port returns (0, nil) and bufio retries that a hundred
times: a 4 s timeout became ~7 minutes of a frozen poll loop logging
nothing.
The controller then answered at once. Confirmed on hardware: the USB cable
presents TWO COM ports, only the second reaches the controller, and only at
19200 baud — so the speed is pinned in code (an FTDI cable opens at any
speed, and a wrong one is indistinguishable from a dead controller) and the
port field says which one to pick. The first exchange after each connect is
hex-dumped, which separates silence from a wrong baud from a misread frame.
Databases now carry only the tables their role needs. Every target used to
get the whole migration set, so a shared MySQL logbook grew settings and
station_profiles tables nothing ever wrote to — an operator inspecting the
server could not tell which copy was authoritative. Statements are filtered
by role, unknown tables are kept in both (fail-safe), and existing databases
are cleaned once, dropping only EMPTY tables. Settings → Database gains a
Compact button, since SQLite frees pages inside the file and never shrinks it.
Also:
- Awards: the callsigns behind a cell open the QSL Manager on Paper QSL,
searched, ready for the card dates.
- The record button no longer goes missing after an update: whether manual
recording is possible is a per-profile question that was asked once, at
startup, before the profile was known.
- Alert rules and filter presets confirm that they were saved.
- Spot clicks on the radio panadapter carry the POTA park into F3.
- The build gate is re-checked wherever the active callsign can change; it
ran at startup alone, and a fresh install has no callsign then.
The COM port was a bare text field — the only serial device in the app without
a port list, and typing one by hand gave no clue when it failed.
A Combobox rather than the Select the other devices use, deliberately: the port
of a USB adapter that is not plugged in does not appear in any list, and
refusing a typed value would mean the antenna cannot be configured until the
adapter is in. Detected ports are offered, anything else is still accepted, and
the value is trimmed and upper-cased on the way in.
The failure itself was already logged by the SteppIR client ("cannot open COM7
@ 4800 baud"); what was missing was the line above it not claiming the antenna
had connected. That is fixed separately.
Carries the 0.26.2 changelog entries for this and the three preceding commits —
one file, and splitting it four ways would have said less than this does.
Three faults an operator's log finally made visible, plus the interface
work that came out of the same session.
Reliability:
- UDP events were dropped on backpressure without a word. A period hands
over twenty-odd decodes at once, and one slow write to the radio was
enough to fill the queue — so a decode simply never appeared, and the
only detector was the operator comparing the panel with JTDX. The drop
is now counted and logged, panadapter spots went to their own goroutine
so the radio can no longer hold the decode stream up, and the queue is
deep enough for a full period.
- The CAT manager waited for its poll loop with a bare <-done. A loop
wedged in a serial read then blocked every later restart inside Start,
before it could even try to connect: the rig stayed dead, no line was
written anywhere, and only killing the process recovered it. The wait
is bounded at ten seconds and says what it abandoned and why the next
connect may fail.
- Shutdown had no logging at all, so a hang left nothing to go on and a
process the operator had to kill — which then blocked the restart after
an update. Every step is logged, and a watchdog forces the exit if one
of them never returns.
Auto-call:
- A QSO in progress is now held by OpsLog itself rather than inferred
from the sender's Status. The moment WSJT-X/JTDX dropped the DX call or
the Enable-Tx flag between overs, the exchange looked finished and the
next CQ was answered, interleaving two and then three QSOs on one
slice. Released on log, on halt, on taking over, and by a watchdog.
Cluster console:
- Replies to a command were buried under the spot flood; a Replies
toggle hides the DX spots, which the list above already shows.
- Twelve named command buttons beside the input, configured in
Settings -> Cluster; a button with no command is not drawn.
- Following the tail is now an explicit switch, and sending a command
re-arms it. It used to measure "am I at the bottom" AFTER committing
the new lines, so a ten-line reply looked like the operator had
scrolled up and was never followed — the one case it exists for.
Awards:
- An award can name NO field. The matching controls disappear with it
and only hand-assigned references count, which is the only thing that
can feed a reference like WWBOTA. A test pins that nothing else is
scanned.
- WWBOTA added to the catalogue with its 31 342 references.
Elsewhere: the rotor widget's Stop button acknowledges the press like
the direction presets already did, and the docked band map can be
switched to fit-to-band from its own header.
It joins the left/right dropdowns in Settings -> General alongside the maps,
the cluster and the rest, so decodes can sit beside the entry strip instead
of only behind a tab. Per-profile like the other pane choices.
The panel itself is now built in ONE place and rendered from both: two
copies of that call would be two sets of props to keep in step, and the
click handler in particular is not something to duplicate.
The status refresh follows. Its "is anything showing a spot status?" test
decides whether a logged QSO refreshes the NEW badges now or only marks
them dirty, and a panel that had become a pane would have gone on wearing
stale badges whenever it was shown that way rather than as a tab.
Wanted for the case where the answers are moving: an operator correcting their
own QRZ record, or chasing a DXpedition whose page changes during the operation,
otherwise waits out thirty days before OpsLog will ask again. Clearing the cache
by hand works once; this is the setting for a whole session.
Nothing is read from it and nothing is written to it — rows stored while it is
off would only sit there going stale, waiting for the day it comes back on.
Switching off is NOT clearing: what it already holds stays, and the Clear cache
button remains the way to throw that away.
Two distinctions the code now has to keep, both load-bearing:
An EXPLICIT stored zero is off; an ABSENT key is the thirty-day default. Every
operator who has never opened this setting has nothing stored, and reading that
blank as a zero would silently switch the cache off for all of them.
The CONSTRUCTOR's zero is still the default, not off. At startup the settings
have not been read yet, and beginning with no cache would hammer the provider
for the first seconds of every launch. Only SetTTL, called once the operator's
settings are known, can switch it off.
A negative lifetime is meaningless and is ignored rather than rounded into
either meaning.
The input had to change too: it derived its value from the stored number on
every keystroke, so the box could not be emptied — and 0 was unreachable
outright, since parseInt('0') || 30 is 30.
internal/rigctld exists because Windows gives a COM port to ONE process: the
moment OpsLog talks to the radio natively, nothing else can. It answers the
programs that speak Hamlib NET rigctl. This answers the ones built around Expert
Electronics' TCI instead — and it answers them whatever radio is connected,
because it sits on the same backend-agnostic Rig interface. An operator with an
Icom or a Yaesu can now hand a TCI-only program a working rig.
One server or the other, never both. They answer the same questions about the
same radio, nothing speaks both, and a second listener is only a second thing to
go wrong.
Written against the official TCI Protocol document (ExpertSDR3/TCI, 12 January
2024, MIT — downloaded and read, not recalled): the initialisation set of §4.1
in its documented order, and the argument order of every command from §4.2. A
client will not proceed past connect without that block, which is why it is
written out in full rather than stubbed.
The one dangerous detail is the VFO mapping. TCI's channel A is where you
LISTEN and channel B where you transmit — the opposite way round from OpsLog's
RigState, which follows ADIF. Getting that backwards would put a station on the
DX's own frequency, so it is pinned in both directions by a test, and RxFreq was
added to the adapter rather than inferred.
Writing channel B while the rig is simplex is ignored: the client asked to
prepare a split transmit frequency, not to QSY, and a logger doing that on every
spot click would drag the operator off the station they were listening to. A
backend that cannot split still refuses out loud.
Only changes are pushed. TCI clients redraw on each command, so re-sending an
unchanged frequency four times a second makes a VFO readout flicker and fights
the operator's own tuning.
Nine tests, no socket needed — the protocol is the decision, not the transport.
The three layers underneath were already there and unreachable: the change-log
format (7d664bd), the identity column (724e68b) and the no-backfill decision
(c48294b). This is the wiring that gives the operator a switch.
Settings, all profile-scoped, because each profile can point at its own logbook:
the folder, this PC's name, the machine id minted once from it, the per-peer read
offsets and the tie-break counter. Scoping the machine id is what keeps two
profiles sharing one folder from writing two logbooks into one file.
Three hooks. Add and update publish asynchronously, down with the rest of the
after-the-fact work — a folder on a network share can block for seconds and a
contact belongs on screen long before another machine hears about it. Deletion
publishes SYNCHRONOUSLY and BEFORE the row goes, for the same reason
deleteRemoteCopies does: once it is gone its identity is gone with it and the
tombstone names nothing.
The apply path uses the repository directly and never AddQSO/UpdateQSO/DeleteQSO
— those publish, and a change applied here would be written straight back out,
two machines echoing each other for ever.
Saving writes a probe file to the chosen folder rather than asking whether it
exists. A read-only cloud folder, or a share whose credentials expired, exists
perfectly well and would swallow every contact in silence; if the probe fails the
switch goes back off instead of sitting on while nothing is written.
The panel is mostly status, and deliberately: every part of this runs on another
machine and on a sync client OpsLog cannot see, so "it is not working" has to be
answerable from the settings page — which PCs are in the folder, when each last
logged, what is waiting unread.
Four tests on the apply path, the middle two being the ones that matter: an edit
made on the other PC lands on the copy already here, matched on the contact
itself, instead of becoming a second row — that is what makes the no-backfill
decision safe — and a contact with the same station on another band stays a
separate contact.
The four buttons on the left change WHICH settings database is in use; the two
on the right act on the file already there. Splitting them by that line makes
the row read as two groups instead of six equal choices, and it stops the pair
wrapping to a ragged second line under the others.
ml-auto rather than a second container, so they still wrap gracefully when the
panel is narrow.
Also removed: "OpsLog can copy the SQLite database to a folder of your choice
when you close it, once per day. Rotation keeps the last N copies…" — everyone
knows what a backup is, and the controls underneath say the same thing in their
own labels. Gone from both dictionaries, and the bilingual test passes.
Text only — every feature stays exactly as it was.
gen.mwDesc what a Most Wanted rank is
bk.hintMysql what the on-close backup does with a MySQL logbook
db.profileHint that the logbook follows the active profile
db.mysqlHint that several OpsLogs on one MySQL see each other live
They explained things an operator already knows, in a settings panel that has
plenty to read as it is. The backup header keeps its ordinary hint; only the
longer MySQL variant goes.
Each removed from BOTH dictionaries: a string left in one and dropped from the
other shows the bare key in the other language, which is what
TestEveryStringIsInBothLanguages exists to catch — and it passes.
A field log showed three pulls of the same 123 615 QSOs inside ten seconds, the
Go heap going 725 MB → 2213 MB → 2539 MB. It is released after the idle TTL, so
not a leak — just the same work done three times with all three results alive at
once.
The cache lock was released before the logbook was read, so every caller that
arrived during a build missed the cache and started its own. Opening the Awards
panel does exactly that. One builder at a time now, with the usual re-check
after taking the lock: the second and third caller wait out the seconds they
were going to spend anyway, minus two round trips to the database.
The slice is also sized from the previous build. Growing to 123 000 structs by
doubling copies the whole thing a dozen times and holds the old and the new
array together at each step, on the largest object OpsLog keeps.
Also, the settings panel registry. The hook trap that broke the window when the
power-supply panel was opened was headed off by a comment, and the comment did
not survive contact with the next panel — so it is now structural. PanelHost is
a module-scope component that calls the selected panel and is keyed by section:
hooks inside a panel land in a component context that persists, section changes
remount it so each gets a fresh and consistent hook list, and no panel state
leaks into the next.
Rendering the panels as <Panel /> instead — the obvious refactor — would have
been wrong: they are nested inside SettingsModal and close over its state, so
each parent render makes a new component TYPE and React would unmount and
remount the panel on every keystroke.
Field report from a tower: on a RAK/RAU in Rot1Prog, every commanded heading
made the antenna want to turn nearly a full circle ANTICLOCKWISE — 0°, 90°, any
of them — while the heading readout, the stop button and everything else worked.
BuildSet framed the four-digit Rot2Prog azimuth for both dialects. A Rot1Prog
reads three: its replies are three digits in a five-byte frame, and its command
field matches. So 90° went out as "0450" and was read as 045 — 45 − 360 = −315°.
Every target landed 360° low, which is why it was always anticlockwise and
always nearly a full turn. The operator's own guess, that OpsLog was in 720°
mode, was the right instinct in the wrong place: the fault is a decimal shift,
not a range.
The round-trip test added here is the one that would have caught it without a
tower — every degree of the circle through the command builder and back through
the reply parser, which must return the degree that went in. The frame tests
pinned the Rot2Prog form against the reference and said nothing about the other
dialect.
Two more from the same report. A rotator test that only READS the heading — SPID,
ARCO, DCU-1 — said "Packet sent, the antenna should swing to north, check
PstRotator's UDP listener", naming a program not in the path for a move never
commanded; it now says the controller answered and nothing was moved. And the
compass polled every three seconds, so a turning antenna moved the needle in
steps of about thirteen degrees; the heading now has its own 700 ms tick while
the relay boards and the antenna controller stay at three seconds.
It held a useState and a useEffect of its own, and the panels in that registry
are called as plain functions — PANELS[x]() — not rendered as elements. So its
hooks landed in SettingsModal's own hook list, and only while that section was
open: React counted more hooks than the render before and stopped drawing the
whole window (error #310).
The file says so three lines above the entry I added, on the two panels that DO
carry hooks and are therefore wrapped in JSX. Reading it would have been quicker
than the screenshot.
No hook here now. The COM ports come from the list SettingsModal already loads
when it opens, for the Winkeyer panel — one machine, one set of serial ports,
fetched once instead of twice.