Reported on an IC-9100: the MOX button does not transmit, it sets split. The
source sends the PTT command (0x1C 0x00) and nowhere sends the split one (0x0F),
so the discrepancy is between what OpsLog sends and what the rig acts on — and
that link has already been shown, in the same operator's log, to lose frame sync.
Rather than guess from the command table, this adds what settled the WinKeyer
bug in one line: the actual bytes. Settings → CAT → Log the CI-V protocol writes
every frame in both directions as hex. RX is traced BEFORE framing, since the
bytes as they arrived are what reveals a lost boundary — a decoded view would
hide exactly the fault being hunted.
Session-only, like the keyer trace: it is a diagnostic, and a log full of hex
helps nobody who forgot it was on.
I am not claiming a cause yet. The last time I inferred one from a protocol
document rather than from evidence, I inverted a digit and broke the case that
worked.
A sixth CAT backend, talking to a TS-590/890/990/2000 over its serial port with
no OmniRig in between — frequency, mode, VFO, split and PTT. Elecraft K3/K4 and
the "Kenwood" setting on other radios speak the same dialect.
The protocol was not researched from scratch: internal/catemu already ANSWERS
these commands, pretending to be a TS-2000 so an ACOM amplifier follows OpsLog.
The IF frame layout here is read from the same format string catemu emits, so
the two halves of the repository agree by construction — and the test caught my
own fixture being one character short, which is exactly the error that layout
invites.
Design notes worth keeping:
- IF; is the poll. One frame carries frequency, TX state, mode, VFO and split,
so simplex operation costs a single round trip; the other VFO is only asked
for when split is actually on.
- FA/FB take ELEVEN digits here where Yaesu uses nine. That is the likeliest
place to copy the Yaesu backend and be wrong by a factor of a hundred, so it
has its own test.
- Every lesson the Yaesu backend learned the hard way is built in from the
start: replies matched to the command that asked, "?;" remembered so a poll
stops paying a timeout for an unsupported command, the serial handle closed
before reopening, and a rig that answers nothing reported as absent rather
than "connected".
Untested on hardware — I have no Kenwood here. The frame parsing is covered by
tests against catemu's own format.
An ERC (Easy Rotor Control, incl. ERC Mini) emulates Yaesu GS-232A/B, which is
exactly what the backend written for the microHAM ARCO already speaks — azimuth
out (Maaa), azimuth in (C), stop (S), which is the whole of what was asked for.
So this is two small gaps rather than a new backend:
- Serial speed was hardcoded to 9600. An ARCO's virtual COM ignores it, but an
ERC runs at whatever its own configuration sets, and a mismatch reads as a
dead rotator. It is now selectable beside the COM port.
- The entry was called "microHAM ARCO", so an ERC owner would never have found
it. It is named after the PROTOCOL now: "GS-232A controller (microHAM ARCO,
ERC…)".
The help text states the condition plainly in both languages, because it is the
one thing that will otherwise waste an evening: an ERC left on Hy-Gain DCU-1
speaks a different command set and simply will not answer.
Untested on hardware — I have no ERC here, and the GS-232 path itself is proven
on a real ARCO.
Spotted by the author: on SQLite the database chip showed a.dbPath — the
settings/profile database — under a tooltip reading "Local SQLite logbook".
Those became two separate files when the logbook was split out, so an operator
checking where their QSOs live, or which file to copy before a trip, was pointed
at the wrong one. MySQL was already right.
It now resolves the logbook the same way connectLogbook does: the active
profile's own file if it names one, then the default logbook.db, and the settings
db only in the case where it genuinely doubles as the logbook.
Also moves the 4O3A mark beside its menu label instead of the far edge of the
row, as asked.
The wordmark I put there was not what the author expected: the brand is "4", a
green waveform of stacked lenses, then "3A".
Only the waveform is SVG. The digits stay HTML text so they keep the sidebar's
own typeface at any theme or zoom — an SVG <text> would pick its own font and
drift from the menu around it. Seven ellipses, tallest in the middle, match the
shape of the mark.
Still drawn rather than fetched: an image off the web has no verifiable
provenance, and this stays one small component to swap if the official SVG is
preferred.
Antenna Genius and Tuner Genius now carry a small 4O3A wordmark, so the two
panels that drive that hardware are recognisable without reading the labels.
Drawn inline rather than shipped as an image file, following the language
picker's flags: it scales with the row, follows the theme through currentColor,
and adds no binary asset to the repository.
It is a plain wordmark, not the manufacturer's logo artwork — I did not pull an
image off the web, since I cannot verify the provenance or licence of what I
would find, and redistributing a company's mark inside the product is the
author's call. The component is one function and takes the official SVG in its
place if that is preferred.
Not applied to the Amplifier panel: it covers both the 4O3A PowerGenius XL and
the SPE Expert range, so a single vendor mark there would be wrong.
The messages went to the radio exactly as recorded. Nothing in OpsLog could
raise them, so a microphone captured quietly drove the rig quietly and the only
remedies were the radio's own USB input menu or the Windows mixer — which is
where the operator was heading. There is now a level from 10 to 400 %, applied
with clamping (a wrap would turn loud speech into noise on the air), and Play
previews at that same level so the adjustment is made against what will actually
be transmitted.
The PTT method list also named only OmniRig, Flex, Icom and TCI, so choosing a
native Yaesu left "CAT" with no backend beside it — which reads as "there is no
CAT PTT for my radio" and sends the operator to RTS on a COM port that has
nothing to do with the rig. Same list-needing-every-member shape as three
earlier bugs in this feature. The TestPTT log line had the same rot: it said
"CAT via OmniRig" whatever backend was running.
Selecting the Yaesu keyer fell through to the WinKeyer branch of the settings,
which offers a serial port picker and a Connect button. So the operator went
hunting for the right port — trying the standard COM and the enhanced one in turn
— and neither connected, because this keyer uses NEITHER: it keys over the CAT
link already configured in Settings → CAT.
It now has its own branch, like the Flex one: a speed field, the warning when the
CAT backend is not a Yaesu, and a line saying explicitly that keying rides the
CAT link. Speed changes go to the rig's keyer instead of a WinKeyer that is not
there.
The radio has a keyer and a command to feed it (KY), so an FTDX10 needs no
WinKeyer and no second cable, exactly as the Icom CI-V and Flex CWX engines
already do. The rig keys with its own timing, which is why the spacing is right
where a PC keying a line through USB latency drifts.
Text is filtered to what the keyer can actually send: an unsupported byte does
not produce an error on a Yaesu, it can abort the whole buffer, so the rest of a
macro would vanish silently. It is then fed in 24-character pieces, waiting for
room between them — the rig DROPS what does not fit, again with no error, so a
contest CQ would lose its tail.
STOP is the honest gap. Yaesu documents no buffer-clear, so it drops the
transmitter (TX0) instead: nothing queued reaches the air, which is what Escape
means to an operator. It deliberately does NOT send "KY0;" — a plausible-looking
clear that the rig would read as the CHARACTER zero and transmit.
A test caught a real one on the way: tabs and newlines were dropped as
"unsupported", gluing the words either side together, so a macro written on two
lines went out as CQCQ. Whitespace now becomes a word gap before filtering.
Settings warn when the Yaesu keyer is selected without the Yaesu CAT backend —
otherwise it simply never keys, with nothing on screen saying why.
Send path follows the CAT reference and how Hamlib drives these rigs; NOT yet
verified on the air.
A console pane for the native Yaesu backend, in the same shape as the Icom and
Flex ones: S/PO/SWR meters, band and mode rows, AF/RF/squelch, AGC, the IPO/AMP1/
AMP2 front-end selector, ATT, NB, DNR + level, narrow filter, power in watts, mic
gain, VOX, split and ATU tune.
Three decisions worth keeping:
Panel reads are STAGGERED and live in their own file, away from ReadState. Meters
poll every cycle; settings only change when someone turns a knob, so they refresh
every 8th cycle and right after any set. Polling all of it every cycle would put
twenty queries a second on the serial link the frequency display shares.
Band buttons use the rig's own band memory (BS) rather than a frequency we pick,
so 20 m lands where the operator last was on 20 m — what the radio's own band
keys do.
A set is followed by a read-back, so the panel shows what the RIG ended up with,
not what we asked for; the two differ whenever a value is out of range or the
mode forbids the control. And a control the model lacks keeps its previous value
instead of dropping to zero, which reads as a setting that reset itself.
The S9 point of the S-meter scale is a hypothesis (the manual does not state it)
and is commented as such — one number to correct if reports come out an S unit
off, rather than a fudge spread through the RST helper.
Also removes the FlexRadio settings blurb, which explained the backend to
someone who had already chosen it.
Xiegu speaks CI-V with a reduced command set: frames, BCD encoding, addressing
and the opcodes for frequency, mode, PTT and split are Icom's, so this reuses
internal/cat/civ wholesale instead of re-deriving a codec.
It is a SEPARATE backend rather than the Icom one at address 0x70, because what
the two rigs do NOT share is the deciding part. The Icom backend reads the
spectrum scope, the DSP block, data mode via 1A 06 and the model id via 19 —
none of which a Xiegu implements. Pointed at a G90 it would poll every cycle for
answers that never come, and spend its silence tolerance on commands the radio
was never going to support.
Two consequences of the rig's smaller mode table are handled explicitly rather
than left to fail: there is no data mode, so a digital QSO is set to plain
sideband (what the operator does on the radio anyway) instead of being refused;
and the split TX frequency is NOT reported, because reading the unselected VFO
needs 0x25, which the Xiegu table does not list — a split flag carrying a wrong
TX frequency is worse than the flag alone, since the frequency is what gets
logged.
The published command table has rows that slipped during typesetting (0x07 and
0x0F share a block). Where it contradicts itself the Icom meaning is used, the
rest of the table matching Icom exactly, and every unexpected reply is logged
raw so a first on-air run settles it.
NOT yet verified on a radio.
A native CAT backend owns the rig's serial port, and Windows gives a COM port to
one process — so choosing native CAT locked WSJT-X, MSHV and JTDX out of the
radio entirely. That is the cost of dropping OmniRig, which was itself a sharing
layer, and it has to be paid back.
OpsLog now becomes the server, as wfview does. It speaks the Hamlib net rigctl
protocol, which every one of those programs supports natively (rig model "Hamlib
NET rigctl", 127.0.0.1:4532) with no driver to install. It sits in front of the
MANAGER, not a backend, so an operator on OmniRig, Flex, Icom or TCI gets the
same server.
Two details that decide whether a client works at all rather than degrading:
dump_state is parsed positionally and WSJT-X refuses to proceed without a
well-formed block, so it is written out in full and its shape is pinned by a
test; and set_vfo / set_split_vfo answer RPRT 0 rather than an error, because
OpsLog follows the rig's own VFO and a refusal makes WSJT-X abandon the
connection. Unknown commands answer RPRT -11 — never silence, which hangs a
client instead.
The whole protocol is tested against a fake rig, plus one end-to-end exchange
over a real socket, since the framing is as much the contract as the text.
Also: the Yaesu backend is confirmed working on a real FTDX10 (frequency, mode,
VFO, split), so its "not yet verified" note is now wrong and is corrected.
Every Yaesu fault reported so far came from OmniRig's interpretation layer, not
from the radio: a rig file that never exposes the VFO, a Freq property meaning A
on one model and B on another, a split flag that alternates between polls. This
talks to the rig directly, so what the radio answers is what is shown.
Modern Yaesu CAT is plain ASCII with a ';' terminator — FA/FB for the VFOs, MD0
for the mode, VS for the selected VFO, TX to key. Frequency is written to the VFO
the operator is actually on, not always to A, which is the failure that made a
display disagree with the radio.
Two things are genuinely uncertain across the family and are treated as such
rather than guessed. SPLIT is read through ST, then FT if the rig ignores ST —
whichever answers wins and the choice is remembered, because the two commands say
DIFFERENT things (a split flag vs which VFO transmits). If neither answers, split
is reported OFF and the fact is logged, rather than invented. Unknown model ids
and mode bytes are logged raw for the same reason.
Split resolution, frequency parsing and the mode mapping are pure functions with
a table test — the OmniRig equivalent is where every Yaesu bug lived, and it had
no test until late.
Written from the CAT reference; NOT yet verified on a radio.
Adds the IC-7300MKII at CI-V 0xB6.
Doing so exposed a drift between the two hand-kept copies of the model table: the
settings offered the IC-7700 at 0x88 and the IC-7800 at 0x80, which are the
IC-7100's and the IC-7410's factory addresses. Picking either set an address the
rig never answers on — the symptom is a radio that simply stays silent — and the
backend then named it as the other model. Corrected to 0x74 and 0x6A, and the
four models the backend already knew (IC-7100, IC-7410, IC-7600, IC-7851) are now
offered too instead of forcing a manual address.
A test reads the model list out of the .tsx and asserts civ.ModelName agrees, so
the next model added on one side alone fails the build rather than someone's
radio.
The profile's MY_* metadata is derived from the callsign through cty.dat, and the
effect that derives it ran on every load — so opening the settings counted as
"the source changed" and overwrote whatever the operator had typed. Reported by
an operator in CQ 4 / ITU 4 handed 5 and 9: he corrected them, and each restart
put 5 and 9 back.
cty.dat gives the zones of the ENTITY, and a large country spans several, so the
automatic value cannot be treated as authoritative — it is a starting point. A
load now fills only fields that are EMPTY; a recompute that overwrites happens
only when the callsign or grid itself changes, which is the case the derivation
exists for.
The load-vs-edit distinction is a ref holding the profile id the values were last
derived from — first sight of a profile is a load.
Every port box was parseInt(e.target.value) || <default>. Delete the contents
and parseInt gives NaN, so the default is written straight back: the digits
reappear under the cursor and the only way to enter a different port is to
overwrite it character by character. Reported on the cluster editor; the same
line existed in eight other places.
One PortInput component now holds the raw TEXT as its state and only tells the
parent about a value that is actually a port. An empty box stays empty while you
type; on blur an invalid one falls back to the default, so nothing is ever saved
as 0 or NaN. It adopts a value arriving from the backend only while the operator
has not started typing — re-syncing mid-edit is the behaviour being fixed.
This is the controlled-input trap the project notes already warn about: keep the
raw text in local state and derive the stored value from it.
My mistake yesterday: the new confirmation columns went into uploadStatusCols —
the QSL Manager's FILTER whitelist — instead of bulkEditableCols. The dialog
listed QRZ.com received status and the ten dates, and the repository refused
them at Apply, after the operator had selected 54 QSOs.
Moved to the right map. And two fields have been broken this way since long
before: State and County were offered under "Contacted station" (whose IOTA /
POTA / SOTA / SIG siblings are all allowed) but were missing from the whitelist,
so choosing one always failed. Added — they are exactly what an import loses and
what a whole run shares.
The real fix is the test. Two lists in two languages had to agree by hand and
nothing checked it, so the failure only ever surfaced as an error message at the
last click. The new tests read the ACTUAL field ids out of BulkEditModal.tsx and
FilterBuilder.tsx and assert the repository accepts every one — a field added to
the UI alone now fails the build instead of the operator.
Statistics — the activity chart ignored the period selector: picking a year up
top left it showing the last 7 days, two controls contradicting each other. The
buttons were four fixed rolling windows anchored on the newest QSO, not
granularities. They now choose the BUCKET SIZE over the selected period, with an
Auto default and a step-up when a bucket would be too fine (the backend drops a
series past 750 buckets rather than ship 6000 unreadable bars). The hour-of-day
histogram covered a single day, too little to read anything from; it moves to
its own card with a weekday view, over the whole period.
Band map — the CW/data/phone sub-bands were shaded with the STATUS tokens, the
same amber that means "new band" on the pills drawn on top of them. A sub-band
is an identity, not a state: categorical hues now, validated in both themes
(violet failed on the dark steps — 1.9 ΔE from blue for a protan reader) and
added to the legend, since identity must never be colour-alone.
Frameless window — the OS title bar was a dead 32px band above a window that
already has its own. Minimise/maximise/close move into the app header, which
carries the drag region and double-click-to-maximise. The drag opt-out is by
ROLE in CSS, so a future button in that bar keeps working without anyone
remembering the rule.
Fixes:
- Saving settings froze the window while a device was slow: restarting a link
waits for its poll goroutine, which can sit 45 s inside an uninterruptible COM
Connect when another program holds the rig. The restart is now off the UI
path; a slow one is logged.
- Multi-screen: a MAXIMISED window was never repositioned, so it came back on
the primary screen every launch. The corner is now recorded even when
maximised (it names the monitor) and re-applied while still hidden.
- The Callsign field is marked out at rest — operators were typing the call into
Name, which sat beside it and looked identical.
- QSL dates get a real picker (native, for the OS calendar and locale order); a
malformed old value stays in a text box rather than vanishing behind an empty
one.
Also: a Support OpsLog entry in Help, and a WinKeyer protocol trace. The WK2
report (one element then a ten-second pause, sidetone that will not switch off)
is NOT fixed here: the WK1/WK2/WK3 command sets differ and a guessed fix would
break the operators it works for today. The trace logs every byte with the
command name and spells out the firmware family, which is what will settle it.
On its CAT/AUX connector an ACOM is the MASTER: it polls a transceiver and
changes band from the reply, so nothing can be pushed to it. internal/catemu
answers those polls on a second serial port, in ACOM command set 5 (Kenwood /
Elecraft): FA;, FB;, IF; and ID;, and nothing else — a wrong-length reply is
worse than none, it desynchronises the amp's parser for the following poll.
Also offered for SPE. Some amps do not poll at all but read the radio↔PC CAT
line in parallel; those never hear a responder, so an optional unprompted send
(500/1000 ms) covers them.
The TX frequency is what is sent: in split the amp must be tuned where we
transmit. Frame lengths are pinned by tests — the failure they guard against is
silent and only shows up as an amp that mistunes.
Untested on hardware.
- SCP/N+1: new internal/scp downloads the community MASTER.SCP master list and a
docked two-column widget shows, as you type a call, the known calls containing it
(Partial) and the calls one edit away (N+1) — click to fix a busted call. Opt-in
in Settings → General; top-bar toggle; queried debounced on callsign input.
- Flex: OpsLog's GUI-client detection was too loose and could bind to "SmartSDR CAT"
(or DAX) — both carry "smartsdr" in the program name — instead of the real GUI
client, making SmartSDR CAT drop and reconnect in a loop while OpsLog was open.
Now it binds only to a real SmartSDR/Maestro GUI client (e.g. a FLEX-8600M's
integrated screen) and excludes cat/dax; dropped the risky empty-program fallback.
- Telemetry: on a fresh install the callsign isn't set at launch, so the once-a-day
heartbeat recorded the machine UUID. Now it waits (~10 min) for the operator to
enter their callsign before sending, falling back to the UUID only if none appears.
- Zoom: our own Ctrl+wheel zoom (CSS zoom on the root, 50–250%), persisted in
localStorage and restored at startup; Ctrl+0 resets. Replaces the non-persistent
native WebView2 zoom. The freq-digit wheel now ignores Ctrl so it passes through
to zoom.
- Award column widths: they were stripped from AG Grid's saved column state (that
strip fixes a visibility desync) which also dropped their width. Now persisted
separately per award code (localStorage + portable DB copy) and re-applied on
rebuild/reopen.
- CW keyer widget: macros padded to 9 (F1–F9 slot) and empty macros hidden like
the voice keyer, with the F-number kept tied to the real macro index so the
F-key shortcuts still line up. New QRZ? default for F9.
They took vertical space in the CW Keyer panel for text operators already know.
Kept the actionable CAT-backend mismatch warnings and the checkbox labels.
With ESM enabled (Settings → CW Keyer), the keyer active and mode CW, Enter in
the entry strip fires a macro by QSO stage instead of logging:
- callsign field empty → F1 (CQ)
- callsign entered (in call field) → F2 (report), then focus jumps to RST-sent
- Enter in RST-sent / RST-rcvd → F3 (TU), which logs via its own <LOGQSO>
Works for every keyer engine (WinKeyer / serial DTR-RTS / Flex CWX / Icom CI-V)
since it routes through the shared macro sender. Enter in other fields still logs
normally, and ESM off keeps the classic Enter-to-log behaviour.
Backend: new `esm` flag on WinkeyerSettings (winkeyer.esm). Frontend: esmHandleEnter
state machine keyed off data-esm markers on the call/RST blocks, a Settings
checkbox + hint, and i18n EN/FR.
New internal/tunergenius client speaking the same "Genius Series" text API
as the Antenna Genius / PowerGenius XL: banner on connect (with optional
"AUTH" for remote access), "C<seq>|<cmd>\n" commands, "R<seq>|<code>|<msg>"
replies and the "S<seq>|status k=v …" snapshot; async "M|<msg>" info lines
are consumed inline. Polls status ~1.5s and exposes SWR (return-loss dB
converted to a VSWR ratio), forward power (dBm→W), and the operate/bypass/
tuning/active-channel state. Actions: autotune, global bypass, operate/standby.
Controlled directly (not via the radio) so OpsLog uses only one of the box's
four connection slots, per the device's protocol doc.
Wiring:
- app.go: tunergenius.* settings keys, Get/Save/start, GetTunerGeniusStatus,
TunerGeniusAutotune/SetBypass/SetOperate; started in the background at launch.
- Settings → Tuner Genius panel (enable + IP + optional remote code).
- Docked TunerGeniusPanel widget (SWR/power readouts + Tune/Bypass/Operate),
top-bar toggle, shown when enabled — mirrors the Antenna Genius widget.
- i18n EN/FR (sec.tunergenius, tg2.*, tgp.*).
Command verbs (operate/bypass/autotune/status/auth) come straight from the
4O3A "Tuner Genius XL — Protocol Description"; UNTESTED on hardware.
Per feedback: New/Open/Rename/Save-copy/Reset made no sense under the settings
database — moved the meaningful DB actions to the logbook (New database / Open
existing / Rename-relocate). The settings section now shows just its path + Open
folder. Also fixed the "Logbook switched…" confirmation rendering twice (dropped
the duplicate render in the SQLite block; kept the shared one). The unused
settings-db handlers/bindings stay for a later re-add.
"Choose a dedicated file" points at a fresh/empty file; there was no way to
rename or move an existing logbook WITH its data. RenameLogbook VACUUM INTOs the
active profile's SQLite logbook to a new path, repoints the profile and switches
the live logbook (no restart). Deletes the old file only when it was a dedicated
per-profile file; the shared default logbook.db is left for other profiles.
Errors on a MySQL logbook. UI: "Rename / relocate…" button in the logbook section.
Design flaw: opslog.db held BOTH the config (settings + profiles) AND the SQLite
logbook, so the only way to a separate SQLite logbook — the whole-app "change
database location" pointer — swapped the config too, wiping the operator's setup
(reported: creating a new SQLite for a visiting op lost all profiles/settings).
Now the two are separate files:
- Settings database: settings + profiles. Fresh installs name it settings.db;
existing installs keep opslog.db.
- Logbook (QSOs): a dedicated logbook.db next to the settings db, or a
per-profile file (profile.ProfileDB.Path), or MySQL. connectLogbook opens the
logbook file (db.Open creates+migrates on first use); the settings db is used
as the logbook only if the split ever fails.
One-time, non-destructive migration at startup: if there's no logbook file yet
but the settings db already holds QSOs (legacy combined opslog.db), seed
logbook.db with a clean copy via VACUUM INTO — contacts move to the logbook, the
originals stay in the settings db as an untouched backup.
UI: the Database panel now shows the settings database and this profile's logbook
as two clearly labelled sections (+ "Open folder"), and the logbook selector is
SQLite (default logbook.db, or a dedicated file via "Choose a dedicated file…")
vs MySQL — no more confusing shared/separate choice. New binding RevealDataFolder.
Design flaw: the SQLite backend conflated the app/config database (opslog.db —
settings + profiles) with the QSO logbook. connectLogbook returned a.db for any
non-MySQL profile, so the ONLY way to get a separate SQLite logbook was the
whole-app "change database location" pointer — which swapped config + profiles
too, wiping the operator's setup (reported: creating Jerem.db lost all configs).
profile.ProfileDB gains a Path field: a non-empty path routes that profile's
logbook to its own SQLite file (db.Open creates + migrates it on first use),
while opslog.db keeps settings/profiles. connectLogbook opens the file; empty
path = shared db (unchanged default, backward compatible). MySQLSettings carries
sqlite_path; Get/Save wire it through.
UI: the Database panel gains a third backend option "SQLite — separate file"
with a file picker, and now clearly labels the shared application database
(settings + profiles) vs this profile's logbook, so the two are never confused.
A SteppIR only covers part of the spectrum (a standard one is 20 m–6 m) but
can't report its own range, so the follow loop's existing out-of-range guard
(FreqMin/FreqMax) never engaged for it. Tuning the rig to a band the antenna
can't reach (e.g. 30 m) made the loop keep trying — the immediate cause of the
stuck TX interlock addressed in the previous commit.
Add a Tunable range (MHz) setting to the Antenna panel, wired into the SteppIR
adapter's Status().FreqMin/FreqMax so the follow loop skips out-of-range
frequencies entirely: no tune command, no TX inhibit. Defaults to 13–54 MHz
(20 m–6 m, the common model) when unset; widen the low edge for a 40 m-equipped
SteppIR. Ultrabeam is unaffected (it reports its own per-band coverage).
Keeps the last-commanded-freq deadband from the previous commit as a universal
safety net for any flaky-status case within the valid range.
This reverts commit 6a28344. Restore the once-a-day anonymous PostHog heartbeat
and its opt-out toggle: telemetry.go (sendTelemetryHeartbeat, GetTelemetryEnabled/
SetTelemetryEnabled, PostHog host + API key), the startup goroutine, the Settings
→ General toggle + i18n keys, and the README/wiki mentions. version.go is dropped
again (appVersion moves back into telemetry.go). release.ps1 (untracked) pointed
back at telemetry.go by hand.
Drop the once-a-day anonymous "app_opened" heartbeat to PostHog and everything
around it: telemetry.go (sendTelemetryHeartbeat, GetTelemetryEnabled/
SetTelemetryEnabled, install-ID/last-sent settings keys, PostHog host + API key)
and the startup goroutine that fired it. The 'Send anonymous usage statistics'
toggle is removed from Settings → General (TelemetryToggle + i18n keys), and the
telemetry mentions are stripped from the README and wiki.
appVersion (still used by changelog/update/livestatus/log-email) moves to a new
version.go; release.ps1 now rewrites it there instead of telemetry.go.
The External-services panel (HRDLOG, eQSL, LoTW, POTA) and the many input
placeholders across all tabs (QRZ/ClubLog included) were still hardcoded
English. Added ~40 es.* keys (EN + FR) and wired every label, placeholder,
hint, checkbox, button and the "coming soon" fallback through t(). Renamed the
tab-map param off `t` so it no longer shadows the i18n function.
The Password-encryption, ClubLog-exceptions and ClubLog-Most-Wanted blocks in
the General settings panel were still hardcoded English. Added ~30 gen.* keys
(EN + FR) and wired every heading, checkbox label, description, button and
status line through t(), plus the passphrase-mismatch error.
The whole "Manipulateur CW" settings panel was hardcoded in English, so it
stayed English even with the app in French. Added ~35 wk.* keys (EN + FR) and
wired every label/checkbox/select/placeholder through t(). Also removed the long
serial-engine explanation paragraph as requested.
Reported: on a CQ macro the rig drops to RX between words instead of holding TX
for the whole macro. Root cause is PTT not being held (usePTT off, or the RTS
PTT line not wired/honoured). Improvements:
- "Key PTT line" now defaults ON when the Serial engine is selected — without it
the rig runs on semi-break-in and drops between words.
- The serial keyer's line options (PTT, key line, invert, lead/tail, speed) are
now atomic and live-updatable: SaveWinkeyerSettings -> ApplySerialConfig applies
them from the next character, no reconnect needed.
- Each transmission logs its PTT state / key line / lead/tail, so a rig that
still won't hold TX can be diagnosed from the app log.
The macro itself is sent as one string (not fragmented), so PTT is genuinely
held across word gaps when usePTT is on — pending on-air confirmation via the log.
Opt-in (Settings → General). Shows a "MW #rank" pill next to the DXCC entity
name in the entry-strip band/slot matrix — ClubLog's Most Wanted ranking
(1 = most wanted), personalised to the operator's callsign and refreshed daily.
- internal/clublog/mostwanted.go: fetch mostwanted.php?api=1&callsign=<CALL>
(rank→DXCC JSON, real User-Agent), invert to dxcc→rank, cache to
<dataDir>/clublog_mostwanted.json; NeedsRefresh invalidates on callsign change.
- app.go: keyClublogMostWanted setting, a.clublogMW, startup refresh goroutine,
activeCallsign() helper, and Get/Set/Download bindings mirroring the cty ones.
WorkedBefore now carries MWRank (qso.WorkedBefore.MWRank) when enabled.
- BandSlotGrid.tsx: MW pill next to the entity name, colour-tiered by rank.
- SettingsModal General: toggle + download button + status, mirroring the
ClubLog cty-exceptions block.
Also reorganises the changelog: the theme-persistence fix (landed after the
v0.20.11 tag) plus this feature go under a new 0.20.12 entry; 0.20.11 keeps only
what shipped in its binary.
Some CW interfaces key on the opposite line level (transmit at rest / key
backwards). New "Invert keying (active-LOW)" toggle flips the asserted level for
both the CW and PTT lines, and the idle state drives both lines to their
inactive level accordingly so an active-low rig isn't left keyed at rest.
Default off = N1MM convention (line HIGH = active).
Adds a 4th CW keyer engine alongside K1EL WinKeyer, Icom CI-V and Flex CWX:
OpsLog bit-bangs the Morse itself on a serial control line (DTR keys CW, RTS
keys PTT — swappable), the hardware-keying method N1MM/WSJT use with a Yaesu
SCU-17 and generic interfaces. No WinKeyer chip needed.
- internal/winkeyer/serialcw.go: serialKeyer — worker goroutine, morse table,
WPM + Farnsworth timing (live speed changes), abortable, PTT lead-in/tail/hang.
- winkeyer.Config gains Type ("k1el"|"serial") + CWKeyLine ("dtr"|"rts");
Manager routes Connect/Send/Stop/SetSpeed/Backspace/Disconnect to it.
- app.go: keyWKCWLine setting; WinkeyerConnect sets Type from the engine.
- Settings -> CW Keyer: new "Serial port (DTR=CW/RTS=PTT)" engine with COM port,
key-line selector, speed/Farnsworth/lead-in/tail/PTT. Macros, auto-CQ and
<LOGQSO> reuse the WinKeyer path unchanged.
UNTESTED on hardware (no SCU-17 to hand): polarity assumes N1MM convention
(line HIGH = active). Weight not yet honoured; Farnsworth is.
Multi-amp: Settings->Amplifier becomes a list (amps.json, legacy single-amp keys auto-migrate to entry #1); one client per enabled amp with per-id bindings (GetAmplifiers/SaveAmplifiers/GetAmpStatuses/AmpOperate/AmpPower/AmpPowerLevel/AmpFanMode); legacy a.pgxl/a.spe/a.acom point at the first enabled amp of each family. Amp cards in FlexPanel and Station Control gain a dropdown to pick the amp; the status bar shows one clickable chip per amp. Use case: two SPEs run in parallel.
Flex v4 DSP (8000/Aurora): NRL/ANFL (lms_nr/lms_anf), NRS (speex_nr), NRF (nrf) with level sliders, RNN (rnnoise) and ANFT on/off — keys per the FlexLib slice docs; the section only shows when the radio reports these keys (dsp_v4 flag), so 6000-series panels are unchanged.
Implements the SPE Application Programmer's Guide protocol: packets
0x55 0x55 0x55|CNT|DATA|CHK (sum%256), OPERATE key 0x0D (toggles STANDBY/OPERATE)
and STATUS request 0x90 whose 0xAA-framed reply is a 19-field CSV (mode, RX/TX,
band, power level, output W, SWR, V/I, temp, warnings, alarms). internal/spe
polls status ~1/s over USB serial (go.bug.st/serial, 8N1) or TCP (RS232-to-
Ethernet bridge) — same codec, different transport.
Wired via startPGXL (starts the SPE client for spe* types), bindings GetSPEStatus
/ SPESetOperate, and a live status card + OPERATE/STANDBY toggle in the Amplifier
settings panel. Only the two example-anchored commands are sent (safe); other
keystroke codes were ambiguous in the guide's table. Untested on hardware.
Renames the Hardware section to Amplifier and adds an amplifier-type selector
(4O3A PowerGenius XL, SPE Expert 1.3K-FA / 1.5K-FA / 2K-FA) plus a transport
choice for the SPE amps: USB (serial COM + baud) or Network (RS232-to-Ethernet
IP:port). PGXLSettings gains Type/Transport/ComPort/Baud (keys keep the pgxl.*
prefix for back-compat). PowerGenius still drives over TCP; SPE settings are
stored but control is not wired yet (needs the SPE serial protocol).
- Denkovi (FT245 D2XX) now selectable as 4 or 8 relays (a 4-relay board just uses
the low nibble); NewDenkovi takes a count, driven by the device's Channels.
- New 'usbrelay' backend: cheap CH340/LCUS USB-serial boards over a COM port
using the common A0 protocol ([0xA0][relay][state][checksum]); write-only, so
Status is a shadow. Channel count configurable (1/2/4/8/16).
- StationDevice gains Channels; deviceRelayCount() drives label/relay counts for
the variable-size types. Device editor: channel selector + COM-port picker
(usbrelay) / FTDI-serial (denkovi).
Both untested on hardware; the A0 command set / Denkovi bit order may need a tweak
after a live test.
Third relay device alongside WebSwitch and KMTronic. Despite enumerating as a
COM port, this board is driven via FTDI D2XX synchronous bit-bang (one byte = 8
relays, bit 0 = relay 1), not serial ASCII — so we load ftd2xx.dll at runtime
(no CGO) and call FT_OpenEx/FT_SetBitMode/FT_Write, addressing the board by its
FTDI serial (e.g. DAE0006K), exactly like the vendor tool. Windows-only (stub
elsewhere); ListDenkoviDevices enumerates connected serials for the picker.
Wired into relaydev (Count/Status/Set), app.go (deviceDriver/relayCountFor/type
whitelist + ListDenkoviDevices binding), and the Station device editor (new type
+ FTDI-serial field with Detect). Untested on hardware; bit order / on-polarity
may need a flip after a live test.
Adds a Rename button to Settings -> Database: renames the current SQLite database
(e.g. opslog.db -> F4BPO.db) while preserving every setting/profile, unlike New
database which starts empty. Implemented as a VACUUM INTO copy + pointer switch;
the old file (open and locked now) is scheduled via config.json delete_pending
and removed, with its -wal/-shm sidecars, on the next launch.