From an operator's log: an IC-7760 in standby, and OpsLog dialling and
dropping every forty seconds for as long as it was left there — control
link up, login OK, token renewed, and not one CI-V answer.
lastGoodAt bounds "the link answers but no CI-V comes back". It belongs
to a session and was never cleared when a new one opened, so a rig that
went to standby half an hour ago handed every fresh session a
half-hour-old last good read: past the grace before the first command was
even sent. Torn down at once, redialled twenty seconds later, torn down
again. Cleared on connect, the rule reads as it was written — silent
since connect is a rig in standby, and the session is kept so it can be
woken.
The console it is woken from was missing too. It appeared only once the
live CAT state said "icom", which a sleeping rig never says, so the ON
button was absent at the one moment it exists for. It now follows the
CONFIGURED radio — which also had to start following a radio switched
from the status bar, instead of waiting for a trip through Settings and a
Save that changed nothing.
The network backend treated "control link alive but no CI-V reply" as the rig
being in standby, and tolerated it WITHOUT BOUND. When another program takes the
CI-V session — WSJT-X through OmniRig, or the Remote Utility — the rig goes on
answering pings on the control stream while sending us nothing at all. Alive()
stayed true, so ReadState returned the cached frequency with err == nil, the
Manager never saw a failure, never reconnected, and re-published a frozen number
with a fresh timestamp on every poll. Only restarting OpsLog cleared it.
Bounded now, on the last SUCCESSFUL read. Past the grace the error is reported so
the Manager tears the session down and reconnects, which re-takes the CI-V
stream. Also fatal immediately: the CI-V reader goroutine having exited — no read
can ever succeed after that, however healthy the control link looks.
The grace backs off to minutes when the silence persists, because the two cases
pull opposite ways: a stolen session recovers on the first attempt, while a rig
switched OFF is silent for hours and re-tearing its session every 30 s would
blink the panel — and its ON button — away continuously. A good read resets it.
The decision table is pinned by a test; the standby case (never answered since