Commit Graph
25 Commits
Author SHA1 Message Date
rouggy 2f2fced15c fix(cat): make the Kenwood/Elecraft link an explicit USB-or-network choice
The network option IS implemented — the same ASCII CAT over TCP instead
of a cable, for a ser2net bridge, an Ethernet-serial adapter, or a radio
exposing its raw CAT port. What was wrong is how it was offered: the COM
port and the network address sat side by side with nothing to say that
the address wins whenever it is not empty.

Worse, the example address read 192.168.1.50:4532. That is Hamlib
rigctld's port — a different protocol, and the one OpsLog SERVES under
'Share CAT'. Anyone copying the example was pointing the radio link at
OpsLog's own server.

Now one choice, then the fields that belong to it. And when the far end
answers something that is not the radio's CAT, the error says that rather
than 'check the baud rate', which over TCP is advice about a setting that
cannot be the cause.
2026-08-25 17:27:44 +02:00
rouggy f9113b6ad3 fix(elecraft): read the TX meters when the RADIO says it is transmitting
The transmit meters were read on k.tx, which records only that OpsLog
keyed the radio. An operator using the front-panel PTT, a footswitch or
the mic button therefore had a panel that believed the rig was receiving
— and since the power and SWR bars are read only while transmitting,
they were never read at all. IF carries the radio's own transmit bit;
that is what decides now.

The meter probe logs RAW answers rather than parsed numbers, and asks a
wider set (SM, SMH, BG, SW, PO, TQ). A command answering in a shape we
did not expect is the interesting case, and parsing hid it behind the
same dash as a command the radio refused — which is what still stands
between us and a working SWR reading on a K3.
2026-08-24 22:16:53 +02:00
rouggy b38b9030f0 fix(elecraft): MOX would not unkey, and the TX meters never moved
Both are the same bug. ReadState returns early while transmitting — the
rig answers '?;' to IF; then, and treating that as a fault used to drop
the link — but that early return also skipped the panel update and the
meter read.

So the panel believed the radio was still receiving. Pressing MOX again
therefore sent ANOTHER transmit command instead of RX, and the K3 stayed
keyed, exactly as reported. And the power and SWR bars were only ever
read at the one moment they mean nothing.

Reading meters while transmitting needs one more guard: a '?;' then says
when the question was asked, not what the radio supports, so the
unsupported-command memory is suspended for that read. Without it, one
badly timed refusal would silence a meter for the rest of the session.

Adds RIT/XIT offset control (±10/±100 Hz, offset shown), a 4.0 kHz filter
button for FT8, and logs the K3's icon word when it changes: there is no
command for 'is the ATU in line', the reference says the switch functions
show up as icon changes, so an operator toggling the ATU while watching
the log will name the bit and the button can then light up honestly.
2026-08-24 21:06:21 +02:00
rouggy 60dad353ce feat(elecraft): a K3/K4 console — power, volume, S-meter, SWR, MOX, tune
The Elecraft backend already existed; what was missing was somewhere to
operate the radio from. This adds the panel, on the Kenwood-dialect
client the K3 already speaks, in a tab of its own beside the Yaesu and
Icom consoles.

Scope is the six controls asked for and nothing else. Every extra command
added without a radio to test it against is a control that may or may not
do what its label says, and a K3 exposes dozens.

No K3 was available while writing this, so the two halves are treated
differently. The setters are the commands the reference documents
unambiguously and whose effect is visible and reversible (PC, AG,
TX/RX). The meters are the opposite: their scaling differs by model and
firmware, so the raw answers are logged next to the power setting, the
panel says the scaling is provisional, and an unmeasured SWR shows as
'—' rather than as a perfect 1.0 — a good match on an antenna nobody
measured is the reading that costs a radio.

ATU tune sends SWT20 (the K3 front-panel tap) and logs exactly what it
sent, so a wrong mapping names itself instead of leaving an operator
guessing which button OpsLog pressed.
2026-08-24 14:09:28 +02:00
rouggy ee148732dd feat: HAMLOG.online upload and confirmations, Yaesu antenna, a named port holder
HAMLOG.online is a seventh external service: one API key, one ADIF record per
QSO, immediate / delayed / on-close like the rest. They publish no API
documentation, so the protocol is read from THEIR OWN client — the HAMLOG Agent
(github.com/hamlogonline/Agent), which is the authoritative source short of
asking them:

	POST https://hamlog.online/api/agent/
	{"ADIFADD": {"APIKEY": k, "ADIFDATA": record}}   → {"STATUS":"OK"}
	{"KEYSTATUS": {"APIKEY": k}}                     → {"STATUS":"OK","CALLSIGN":…}

Success is STATUS == OK, not "no ERROR field": their failure carries ERROR and
no STATUS, and reading an unknown reply — a proxy page, a maintenance notice —
as an acceptance is how a contact goes missing without anyone noticing.

KEYSTATUS buys something no other service here offers: the key can be checked
BEFORE the first QSO, and the answer names the account. A key pasted from
another callsign is caught in the settings panel rather than through a week of
silent refusals.

Their confirmations are also an award source now, ticked like LoTW rather than
expressed through "custom". It reads the ADIF extras, not a column: the standard
names a field for hamlog.EU and none for hamlog.ONLINE, and borrowing the other
site's field would write a falsehood into every exported log. Three plausible
key names from their own export are accepted too, so nobody has to rename a
column by hand after an export.

Yaesu gains antenna selection (AN), remembered per band — the antenna picked on
a band comes back with it, with no table to fill in anywhere. Rigs with one
socket never answer AN and never show the row; the log says which case it is.

And a serial port that is refused now names its likely holder. OmniRig stays
resident once activated and keeps the port of the rig configured in it, so a
native backend never gets it — "Serial port busy" alone accused nobody, and an
FTDX10 spent a morning being blamed for it.
2026-08-23 12:18:27 +02:00
rouggy e4014e11d2 fix(kenwood): record a frequency set made while transmitting
WSJT-X "Fake It" shifts the dial for the duration of each over and puts it
back afterwards, but the restore is conditional: it reads the frequency back
and only moves the dial if it disagrees with where it believes the radio
should be.

That read lands inside the window where this backend stops polling on
purpose. A Kenwood answers "?;" to IF; while it is transmitting, and treating
that as a fault used to drop the shared CAT link entirely, so the cached
state answers instead. SetFrequency wrote the command to the rig without
touching that cache — so mid-over the cache still described the pre-over
dial, WSJT-X read its own receive frequency back, concluded there was nothing
to restore, and the radio stayed on the transmit frequency. Every later over
started from there.

Reported from a session where the dial stuck at 7075500 after a full FT8
over while a bare TUNE, which never sets a frequency, worked fine.

Only simplex updates the cache. Under split, FreqHz is the transmit frequency
while the write lands on whichever VFO the operator is on, and guessing which
side moved would put a wrong number in front of the operator — a stale one
survives until the next poll.

The test reproduces the reported sequence and fails without the fix with the
same frequency the log shows.
2026-08-12 07:34:21 +02:00
rouggy 43095a1d89 feat(rigctld): split that actually reaches the radio, or an honest refusal
set_split_vfo and set_split_freq both answered RPRT 0 and did nothing. WSJT-X
and JTDX in "Split Operating: Rig" send exactly that pair, believed both, and
transmitted on the RECEIVE frequency — on a pileup, straight onto the DX, while
showing the operator precisely what they had asked for. A lie that leaves no
trace in any log is the worst kind of bug this program can have.

The two commands are honoured as a PAIR. Arming alone does nothing on the radio,
because WSJT-X sends the frequency second and split armed on whatever the
transmit VFO happened to hold is worse than no split at all: it transmits
somewhere the operator never chose. The request is remembered and set_split_freq
does the work.

Kenwood gains SetSplit — FB to place the dial, then FR0/FT1 to arm, in that
order for the same reason. It writes what State() already knows how to read.

Everything else REFUSES, and that is the feature, not a shortfall. Only Flex and
Icom could even toggle split before, neither could set the transmit frequency,
and Yaesu, TCI and OmniRig have nothing at all. A refusal WSJT-X can report —
and act on, by falling back to Fake It — is worth far more than a success it has
no way to check.

Both paths are pinned: split reaching the rig as one armed call with the right
frequency, and a backend that cannot do it producing an error rather than RPRT 0.
2026-08-11 17:53:46 +02:00
rouggy fa01968207 fix(kenwood): split frequencies swapped on transmit
IF reports the VFO "in use". In split that is the RECEIVE VFO while receiving
and the TRANSMIT VFO while transmitting — the backend took it as the receive VFO
in both cases. Everything therefore read correctly until the PTT closed and then
reversed, which is exactly how it was reported from a TS-590 on USB.

The IF frame has carried the transmit bit all along; parseKenwoodIF already
decoded it into f.TX. It was simply never consulted here.

This is not only a display fault. FreqHz is what a QSO is LOGGED on, so a
contact worked in split went into the log on the DX's frequency instead of the
operator's — wrong in the log, wrong in every ADIF exported from it, and
invisible until someone checked a QSO by hand.

The emulated rig in the test package can now be keyed, so the case is pinned
from both sides: verified failing without the fix (tx and rx exchanged) and
passing with it.
2026-08-11 17:28:23 +02:00
rouggy cfdd24d52e fix(kenwood): a busy rig is not a lost rig
A Kenwood answers "?;" while it is busy, and the TS-590SG does it for a moment
after RX; — which is exactly when the poll resumes. One rejected IF; then tore
down the whole CAT link.

The code already knew this. Its own comment says a "?;" to IF; is "a transient
busy, NOT unsupported" and that latching it off "would read as lost the rig".
That reasoning was applied to the unsupported-command map and stopped there: the
call still returned an error, the poll loop still turned it into connected=false,
and the link still dropped.

What it cost was not cosmetic. WSJT-X keys through shared CAT, so it lost the
rig mid-sequence; Hamlib then sent "F 9223372036854775808.000000" - an
uninitialised 2^63 - which OpsLog refused and logged. The operator sees a
frightening frequency error whose actual cause is three lines earlier.

A "?;" is now sentinel-wrapped so the poll can tell "the rig declined" from "the
serial link is gone", and three consecutive ones are ridden out on the last
known state before the link is called dead. Under a second of tolerance: enough
for the rig to finish, far too short to hide an unplugged cable. A serial fault
is untouched and still drops immediately.

Tested against the emulated rig already in this package, with a hook that
answers "?;" on demand: the link survives inside the grace and still reports the
last good frequency, the count resets on recovery so a later busy spell gets the
full allowance, and a rig refusing forever is still reported as broken.
2026-08-11 08:37:24 +02:00
rouggy 18f44a5aa3 fix(cat): read MD6 back as DATA on an Elecraft, not RTTY
MD6 is FSK on a Kenwood and DATA on a K3/K4. kenwoodModeToADIF decoded the
digit unconditionally as RTTY, so OpsLog contradicted the mode it had just
set: SetMode writes MD6 for a digital mode on an Elecraft, then ReadState
parsed the IF frame back as RTTY.

A K3 running FT8 therefore showed RTTY in the status bar, logged its QSOs on
RTTY, and — through the shared CAT server — told WSJT-X/JTDX the rig sat in
RTTY while they had just asked for a data mode. Found in a K3 operator's log:
every cat:state line read mode=RTTY on 21.074 FT8, two lines after OpsLog's
own "MD6;".

The digit now resolves to the configured digital mode whenever MD6 means DATA
on this rig — the Elecraft backend, and the "DATA A - MD6" data-mode option
that exists for it. A plain Kenwood still reads MD6 as RTTY.
2026-08-08 20:13:45 +02:00
rouggy 9c757e5175 feat(cat): distinct Elecraft K3/K4 backend in the rig list
The Elecraft handling was buried in the Kenwood "data mode" option, so users
couldn't find it. Add "Elecraft K3/K4" as its own entry in the CAT backend
selector. It reuses the Kenwood-dialect transport and the Kenwood USB/network
settings (the K3 emulates the Kenwood command set — a separate transport would be
a near-total duplicate), with an `elecraft` flag on the client that forces
digital modes to DATA A (MD6+DT0) — no data-mode dropdown needed. RigState still
reports Backend "kenwood" so the CW-over-CAT keyer capability keeps working.
2026-08-08 14:15:55 +02:00
rouggy 626edca8ba feat(cat): Elecraft K3/K4 DATA A — send MD6 + DT0 on data mode (from the stale branch)
Integrates the fix/jtdx-kenwood-tx work onto main: the Kenwood/Elecraft backend's
"data" data-mode path now sends MD6 then DT0 so a K3/K4 lands in DATA A — the
audio sub-mode FT8 uses. MD6 alone could leave the rig in an FSK/PSK sub-mode
where it keyed but the rear sound-card audio never modulated ("transmits but
nothing comes out"). The data-mode option is relabelled "DATA A — MD6+DT0
(Elecraft K3/K4)". A shared Kenwood/Elecraft backend is kept (the K3 emulates the
Kenwood dialect); the Elecraft specifics live behind the data-mode seam rather
than a 7000-line duplicate backend.
2026-08-07 16:37:55 +02:00
rouggy 761f554ac0 fix(kenwood): keep the CAT link up while transmitting (K3 shared-CAT FT8)
A K3 (and other Kenwood-dialect rigs) answers "?;" to an IF; status poll while
it is transmitting. ask() latched that as "IF unsupported" and ReadState
returned an error, so the Manager dropped the whole CAT link mid-transmit — the
log shows connected=false / "IF rejected" the instant JTDX sent TX;. That tore
down the shared rigctld CAT the digital-mode software keys through.

Two fixes: (1) track PTT (SetPTT) and skip the wire poll while it's held —
ReadState hands back the cached last state, capped at 30 s so a missed
SetPTT(false) can't freeze it; (2) never latch IF/ID as unsupported — those are
universal on Kenwood/Elecraft, so a "?;" to them is a transient busy (mid-TX),
not a missing command.
2026-08-06 17:49:46 +02:00
rouggy 95482ec1d8 feat(cat): per-rig Kenwood/Elecraft data-mode choice (USB / MD6 / keep)
No single Kenwood mode digit fits every rig for a data mode: a K3/K4 wants
DATA (MD6), a TS-590SG/TS-990S data mode is a USB modifier set on the rig,
and MD6 on a plain Kenwood is FSK/RTTY. So the operator now chooses in
Settings → CAT: USB (default), DATA (MD6), or leave the rig's mode unchanged.

Only soundcard/data modes (FT8, PSK, JT…) follow this; RTTY/FSK stays its own
native mode, and voice/CW are untouched (isKenwoodDataMode + test).
2026-08-04 18:14:26 +02:00
rouggy 500fe8bfec fix(cw): activate the Kenwood/Elecraft keyer engine when selected
The frontend engine loader had no "kenwood" case, so a saved engine of
"kenwood" fell through to the WinKeyer default — the Kenwood/Elecraft
CW-over-CAT engine never ran even though the setting showed it selected.

Also clarify the Kenwood data-mode comment: there is no single mode digit
right for both a K3 (DATA=MD6) and a TS-590SG (MD6=FSK), so data stays on
USB as the safe common base; a rig-specific DATA mode is a follow-up.
2026-08-04 17:59:30 +02:00
rouggy 87ff0a9e16 chore: release v0.23.3 2026-08-04 16:46:32 +02:00
rouggy 5777c119cb feat(cat): make the DTR/RTS lowering a setting
Both defaults break someone. 0.22.7 lowered the lines on Yaesu and
Kenwood and silenced a TS-990 whose interface needs RTS raised to
transmit; 0.22.8 stopped lowering them and an FT8 station reported its
output power wandering, cured by closing OpsLog — Windows raises both on
open and the interface reads one as PTT.

So it is now a checkbox on those two backends, off by default: that is
how they behaved before any of this. Xiegu keeps lowering them
unconditionally (its own report, its own explicit keying setting), and
the CI-V backend keeps the behaviour it has always had.
2026-08-01 19:25:04 +02:00
rouggy 0e1e7d9f3c feat(cat): ID 022 is a TS-990S
Reported by one in the field. Kenwood's documentation gives 024 for that
radio; both are mapped rather than betting on which is right, and the log
no longer reads "Kenwood (022)".
2026-08-01 12:09:57 +02:00
rouggy 3dd428d748 fix(cat): stop deasserting DTR/RTS on Kenwood and Yaesu
d4bfd30 fixed a Xiegu G90 behind a DE-19 that keyed on connect, and I
applied the same line-lowering to Kenwood and Yaesu with no evidence that
either needed it. It silenced them: many USB-serial interfaces will not
transmit with RTS low — hardware flow control, or an output stage the
line enables. A TS-990 on COM3 opened cleanly and answered nothing, which
reached us as "CAT stopped working after the update".

Xiegu keeps the behaviour: that is where the fault was reported, and that
backend now has an explicit setting for which line keys the rig. The CI-V
backend keeps its own, which predates all of this.

Kenwood also distinguishes a silent port from one sending data that never
answers, and quotes what arrived — "the rig is not answering" sent an
operator checking the power switch on a radio whose frames were visibly
on the wire.
2026-08-01 12:09:11 +02:00
rouggy c62d992ad6 fix(cat): keep the Kenwood read buffer across commands; log the CAT error
A TS-480 connected, answered ID, then never reported a state:

  discarding " 000000000010000000;" while waiting for IF
  connected on COM3 @ 115200 baud
  cat:state → connected=false freq=0

A headless frame tail can only come from bytes that were thrown away.
ask() buffered into a local slice, so everything left after the matched
frame — including the head of a frame still arriving — went with it, and
the link could sit one answer behind its questions. The buffer now lives
on the backend, and Connect drains whatever the rig said before AI0 took
effect rather than inheriting it.

Also: the cat:state diagnostic prints RigState.Error. It read
"connected=false freq=0" and said nothing about why, so every report of a
CAT failure arrived without the one fact that explains it — the reason
only ever reached a tooltip.

New work moves to 0.22.8; 0.22.7 is released.
2026-08-01 12:04:32 +02:00
rouggy d4bfd30636 fix: serial CAT keyed the radio on connect; Xiegu can key on RTS/DTR
Reported on a Xiegu G90. With the blue programming cable — three wires, no
modem lines — CAT works perfectly. Behind a DE-19, which carries audio, CAT and
PTT, the radio went into transmit the moment OpsLog connected and stayed there.

Windows raises DTR and RTS when a serial port is opened, and the DE-19 reads
them as PTT; Xiegu's own documentation asks for both low. The CI-V backend has
dropped them since it was written, for the same reason on Icom rigs with USB
SEND mapped to a line. Xiegu, Yaesu and Kenwood did not. They do now.

The second half of the report: WSJT-X through OpsLog's rigctld decoded fine and
never transmitted. Nothing was broken in that chain — set_ptt reaches the
backend, which sends the CI-V PTT command, which a G90 ignores. That is why
Xiegu keys on a hardware line instead. The backend can now do that: Settings →
CAT → Xiegu → how the rig is keyed (CI-V / RTS / DTR).

Untested here — no G90 in reach. The operator who reported it offered to try.
2026-07-31 22:16:03 +02:00
rouggy 3a87b58ba3 feat: Kenwood CAT over a network serial bridge
The same ASCII stream over a socket instead of a wire: ser2net, an
Ethernet-serial adapter, a Raspberry Pi at the radio. One TCP transport
presented as a serial port, so the backend keeps a single code path.

Explicitly NOT the radio's own RJ45. A TS-890 or TS-990 speaks Kenwood's
KNS/ARCP there — session, authentication, a different protocol — and that needs
one of those radios in hand to write honestly. The setting's help text says so,
because an operator who plugs in their TS-890's Ethernet port and types its
address deserves to learn that from the interface rather than from silence.

Two details that decide whether this is usable or maddening:

  - A read deadline expiring is reported as "no data yet", not as an error. It
    is exactly what a serial read timeout means to the caller; as an error it
    would make ask() abandon a rig that is merely thinking.
  - The log line names what was connected to. "connected on  @ 0 baud" after a
    network connect sends someone hunting a serial fault that does not exist.

The host wins over the COM port when both are filled: it is the more deliberate
setting, and silently preferring the wire leaves someone staring at an address
they typed and a radio that never answers.
2026-07-30 21:13:19 +02:00
rouggy eb271e8f20 fix: Kenwood split read from FR/FT when the status frame omits it
Reported from a Flex in Kenwood CAT mode: frequency read perfectly, split never
appeared. Not every rig speaking this dialect fills IF's split bit.

Rather than guess which column that firmware populates, ask the question that
DEFINES split — is the transmit VFO a different VFO from the receive one — which
is exactly what FR and FT answer, and the same rule the Yaesu backend settled on
after several wrong turns. FR is also trusted over IF for which VFO is in use:
they are asked in the same breath, and a rig vague about the split bit may be
just as vague about the VFO field.

Cost is bounded: a rig that rejects FR/FT answers "?;" once and is never asked
again, so this is two short commands per poll only where it works. Both paths
are tested against the emulator — split found through FR/FT with IF silent, and
IF-reported split still working on a rig that refuses FR/FT without re-asking.

Also extends the CAT wire trace to the Kenwood backend, ASCII quoted so an empty
reply is visible as such: "" and ";" look identical unquoted, and telling them
apart is the whole question when a rig half-supports a command. If this fix is
not the whole story on real hardware, the trace is what will say so.
2026-07-30 16:50:06 +02:00
rouggy e2d2485703 test: drive the Kenwood backend against a rig that answers
Nobody here owns a Kenwood, and a backend that has never completed a single
exchange is a guess however carefully it was written.

But this repository already contains the other half of the conversation:
internal/catemu ANSWERS this dialect, pretending to be a TS-2000 so an ACOM
amplifier follows OpsLog. The test's responder replies exactly as catemu does —
same FA/FB widths, same 38-character IF layout, same ID019 — so the two halves
are checked against each other instead of against my reading of a manual.

Connect adds a dialPort seam for this; nothing else changed in the backend.

Covered: model identification, simplex on A, everything following the VFO in
use when on B, tuning writing to that VFO rather than blindly to FA, split with
TX and RX the right way round (ADIF FREQ is the TRANSMIT frequency — swapping
them writes the wrong frequency into every logged QSO), the mode digit, and a
silent port reported as not answering rather than as a connected radio. The last
three are each a fault that actually reached a user through the Yaesu backend.

What this does NOT prove: that a real TS-590 answers on the same timings, or
fills every IF field the way its documentation says. That still needs a radio.
2026-07-30 16:36:49 +02:00
rouggy b16cb973f2 feat: native Kenwood CAT backend
A sixth CAT backend, talking to a TS-590/890/990/2000 over its serial port with
no OmniRig in between — frequency, mode, VFO, split and PTT. Elecraft K3/K4 and
the "Kenwood" setting on other radios speak the same dialect.

The protocol was not researched from scratch: internal/catemu already ANSWERS
these commands, pretending to be a TS-2000 so an ACOM amplifier follows OpsLog.
The IF frame layout here is read from the same format string catemu emits, so
the two halves of the repository agree by construction — and the test caught my
own fixture being one character short, which is exactly the error that layout
invites.

Design notes worth keeping:

  - IF; is the poll. One frame carries frequency, TX state, mode, VFO and split,
    so simplex operation costs a single round trip; the other VFO is only asked
    for when split is actually on.
  - FA/FB take ELEVEN digits here where Yaesu uses nine. That is the likeliest
    place to copy the Yaesu backend and be wrong by a factor of a hundred, so it
    has its own test.
  - Every lesson the Yaesu backend learned the hard way is built in from the
    start: replies matched to the command that asked, "?;" remembered so a poll
    stops paying a timeout for an unsupported command, the serial handle closed
    before reopening, and a rig that answers nothing reported as absent rather
    than "connected".

Untested on hardware — I have no Kenwood here. The frame parsing is covered by
tests against catemu's own format.
2026-07-30 11:56:41 +02:00