4 Commits
Author SHA1 Message Date
rouggy 15159f38a5 diag: log SteppIR status frames so a stuck "moving" (TX interlock) is visible
The SteppIR client logged commands it sent but never the status frames it read
back, so a misread motor-status byte — which drives the app's "block TX while
the antenna is moving" interlock on a FlexRadio — was invisible. Log the raw
11-byte frame plus the decoded freq/dir/moving and the motor (buf[6]) and
direction (buf[7]) bytes, but only when the frame changes, to keep the 2 s poll
from flooding the log. Purely diagnostic; no behaviour change.
2026-07-24 13:38:37 +02:00
rouggy b83a4f4455 fix: correcting proper bit to see when Steppir is moving 2026-07-16 00:48:10 +02:00
rouggy 9d7091b1b8 fix: bug on steppir control 2026-07-16 00:42:16 +02:00
rouggy 5b96f53930 feat: While closing OpsLog will keep the same size and position for next launch 2026-07-15 22:03:42 +02:00