2 Commits
Author SHA1 Message Date
rouggy 423cf1f998 feat(relays): follow the entry Band selector when there is no CAT link
Relay automatic control and the band-change outbound rows both hang off the rig
state, which is right when there IS a rig: changing Band in the entry strip
pushes a QSY, the new state comes back through the CAT callback, and the relays
follow from there — which is why this works for anyone with rig control.

Without a CAT connection nothing is pushed and nothing comes back, so a station
whose rig OpsLog does not control changed band and the antenna switch sat
exactly where it was. Reported as automatic control not working; it was never
told the band had changed.

The entry selector now says so itself, but only when the CAT push did not
happen, and never when the band or frequency lock is on: a lock means the entry
is deliberately decoupled from the rig, and moving an antenna to match a contact
logged from last year is worse than doing nothing.

The frequency is passed as unknown on that path — a band selector gives a band
and nothing else, and rules written on a frequency RANGE are left alone rather
than evaluated against a made-up dial reading.

The de-duplication of "is this a new band" is now shared by both sources, so a
station that has both does not command its switch twice for one QSY.

Also: the same credit line as the QSL e-mail now closes the default recording
e-mail body, on the same terms — a default in the template, so a stored one is
untouched.
2026-08-16 11:15:56 +02:00
rouggy 6c2c1f106a feat(udp): custom outbound messages — a trigger, a template, UDP or a URL
The hard-coded emitters each speak one published format at one fixed moment.
This is the escape hatch, and it exists mainly for antenna switches: they are
driven by a URL, and the band change is the trigger they want.

Four triggers, each carrying its own field set: band change (the RADIO's band,
not the entry form — a switch follows the rig, not what is being typed), QSO
logged, rotator command and callsign lookup. The panel prints the fields the
selected trigger can fill, which is the point of the whole thing: a placeholder
the trigger does not carry renders as nothing, and without the list an operator
writes {freq} on a band change and has no way to learn why the switch never
moved.

Three things the panel cannot show, handled here:

  - Escaping. A URL needs every value percent-encoded; a UDP payload must not
    be touched. The first portable callsign, F4BPO/P, puts a path separator in
    the middle of a query string otherwise — it works on the bench and fails on
    the air.
  - Blocking. An HTTP call to a switch that is unplugged would otherwise sit
    for the operating system's timeout, on the path of a band change. It runs
    in the background with a 3 s limit.
  - Silence. A switch answering 404 after a firmware update fails exactly like
    success looks from here, so the status code is logged, throttled per row.

The rotator trigger hooks the COMMAND rather than the SP/LP buttons, so the
compass and a spot click fire it too, and the path ("SP"/"LP") is passed
through because an azimuth alone cannot say which was taken — 137° is short
path to one station and long to another.

Credentials in a URL are stored as typed. That is the operator's call, on the
grounds that this is LAN gear, and the hint in the panel says so.
2026-08-15 01:39:16 +02:00