Files
rouggy 6a6b7ad6c2 chore(tci): probe binary frames per stream type
The frame log had one budget for the whole session, and the first forty
receive-audio frames spend it in under two seconds. A transmit-chrono
frame — the thing the voice keyer will have to answer, and whose size and
cadence cannot be read off the documentation — only appears once the
operator keys the radio, by which time nothing would have been logged.

Counted per type now, so the first frames of each kind are recorded
whenever they turn up.
2026-08-25 08:29:24 +02:00
..
2026-08-21 23:28:55 +02:00
2026-07-26 16:57:19 +02:00