rouggy ede81d3926 fix(catshare): stop FT8 dial drift in shared CAT (rigctld freq echo)
A digital app (JTDX/WSJT-X) sharing OpsLog's rig in "Fake It" split follows
the dial by polling get_freq. Freq() is the last polled value and lags a
set_freq by a poll cycle, so right after a transmission the client read the
still-shifted frequency, mistook it for a manual QSY and adopted it — the dial
crept down every over and never came back. get_freq now echoes the last
commanded frequency until the rig confirms it (or a short deadline passes),
closing the race. Backend-agnostic, so it fixes every rig, not just Kenwood.