rouggy 507d1f0882 fix(icom net): a sleeping rig keeps its session, and the console is reachable
From an operator's log: an IC-7760 in standby, and OpsLog dialling and
dropping every forty seconds for as long as it was left there — control
link up, login OK, token renewed, and not one CI-V answer.

lastGoodAt bounds "the link answers but no CI-V comes back". It belongs
to a session and was never cleared when a new one opened, so a rig that
went to standby half an hour ago handed every fresh session a
half-hour-old last good read: past the grace before the first command was
even sent. Torn down at once, redialled twenty seconds later, torn down
again. Cleared on connect, the rule reads as it was written — silent
since connect is a rig in standby, and the session is kept so it can be
woken.

The console it is woken from was missing too. It appeared only once the
live CAT state said "icom", which a sleeping rig never says, so the ON
button was absent at the one moment it exists for. It now follows the
CONFIGURED radio — which also had to start following a radio switched
from the status bar, instead of waiting for a trip through Settings and a
Save that changed nothing.