Files
OpsLog/internal/cat/omnirig_vfo_test.go
T
rouggy c297f91ca8 fix: a cluster spot dragged the rig from SUB back to MAIN
Reported on an FTDX101 (F4NBZ): listening on the SUB VFO, clicking a spot moved
the radio to MAIN.

SetSimplexMode is the first thing SetFrequency tries, and it means "receive and
transmit here, simplex" — OmniRig applies that to the MAIN VFO by definition. It
is there because several Icoms ignore direct FreqA/FreqB writes, so it stays for
the main VFO; on SUB it is now skipped entirely and FreqB carries the change.

The generic "Freq" property is skipped on SUB too: on several rig files it IS the
main VFO, so writing it would move the VFO the operator is not using — or pull
them back to it, which is the bug being fixed.

An operator on SUB put themselves there deliberately. A spot click asks for a
frequency, not for a change of VFO — that distinction is the whole fix, and a
test pins which property each VFO state writes.
2026-07-29 16:07:20 +02:00

128 lines
6.4 KiB
Go

package cat
import "testing"
// Every known rig's OmniRig behaviour, pinned. These rules genuinely contradict
// each other between models, so a change that fixes one rig must be shown not to
// break another — that is what this table is for.
func TestResolveOmniRigVFOs(t *testing.T) {
const (
a14200 = 14200000
b14205 = 14205000
b21000 = 21000000
)
cases := []struct {
name string
rig string
main, fa, fb int64
vfo string
split int64
sticky bool
wantTX, wantRX int64
wantSplit bool
}{
// The reported failure: FTDX101D, SUB VFO pressed. OmniRig names VFO B and
// reports it as the generic Freq; freqA still holds the main VFO. Preferring
// freqA meant the display never followed the operator to B.
{"FTDX101D on SUB VFO", "FTDX101D", b14205, a14200, b14205, "B", pmSplitOff, false, b14205, 0, false},
{"FTDX101D on MAIN VFO", "FTDX101D", a14200, a14200, b14205, "A", pmSplitOff, false, a14200, 0, false},
// Yaesu fallback for a rig file that names NO VFO at all (the stock FTDX10
// one, confirmed 2026-07-26): the generic Freq matching FreqB is then the
// only sign that the operator is on SUB. It applies ONLY when the enum is
// silent — when the enum names a VFO, the enum wins (pair cases below).
{"FTDX10, no enum, generic Freq is B", "FTDX10", b14205, a14200, b14205, "", pmSplitOff, false, b14205, 0, false},
// Same alternating ini: one poll says OFF while the rig IS in split. The
// latched ON flag has to survive the contradicting sample.
{"FTDX101D split, contradicting OFF sample", "FTDX101D", a14200, a14200, b14205, "AB", pmSplitOff, true, b14205, a14200, true},
// The latch must not manufacture a split out of a stale cross-band VFO B.
{"FTDX101D latch, VFOs on different bands", "FTDX101D", a14200, a14200, b21000, "AB", pmSplitOff, true, a14200, 0, false},
// Pair enums: first letter is the VFO being listened on. Reported by the
// whole Yaesu family; ignoring them pinned the display to VFO A (F4NBZ,
// 2026-07-26 — Log4OM follows SUB on the same rig through OmniRig).
{"pair enum BA, simplex → listening on B", "", b14205, a14200, b14205, "BA", pmSplitOff, false, b14205, 0, false},
{"pair enum BB, simplex → listening on B", "", b14205, a14200, b14205, "BB", pmSplitOff, false, b14205, 0, false},
{"pair enum AB, simplex → listening on A", "", a14200, a14200, b14205, "AB", pmSplitOff, false, a14200, 0, false},
{"pair enum AA, simplex → listening on A", "", a14200, a14200, b14205, "AA", pmSplitOff, false, a14200, 0, false},
// F4?? IC-7610 report, 2026-07-27: the operator's custom rig file declares
// VFO B permanently while they work on the MAIN VFO. OpsLog then wrote to A
// (SetSimplexMode acts on main) and read B — "the frequency never follows
// the knob". Honouring the enum is right in general, which is why the cure
// is an explicit override in the settings, applied before this function.
{"IC-7610 file wrongly says B — enum honoured, hence the override", "IC-7610", 0, 7150000, 14295000, "B", pmSplitOff, false, 14295000, 0, false},
{"same rig with the override forcing A", "IC-7610", 0, 7150000, 14295000, "A", pmSplitOff, false, 7150000, 0, false},
// Non-regression: a rig that does not report the VFO enum keeps the old
// order — freqA, then the generic Freq, then freqB.
{"no VFO enum, freqA populated (Yaesu/Kenwood)", "FT-891", a14200, a14200, 0, "", pmSplitOff, false, a14200, 0, false},
{"no VFO enum, only generic Freq (IC-9100)", "IC-9100", a14200, 0, 0, "", pmSplitOff, false, a14200, 0, false},
{"IC-7610: generic Freq reports B, enum says A", "IC-7610", b14205, a14200, b14205, "A", pmSplitOff, false, a14200, 0, false},
// Split: PM_SPLITON must be read as a BIT. An exact == 0x8000 reported "no
// split" for any rig that sets the flag alongside another bit.
{"split, ON flag alone", "", a14200, a14200, b14205, "AB", pmSplitOn, false, b14205, a14200, true},
{"split, ON flag with extra bits set", "", a14200, a14200, b14205, "AB", pmSplitOn | 0x40, false, b14205, a14200, true},
{"listening on B → TX on A", "", b14205, a14200, b14205, "BA", pmSplitOn, false, a14200, b14205, true},
// Split must NOT be inferred when the rig says OFF, nor from a stale VFO B
// left on another band (the FT-710 / TS-570 false positive).
{"OFF flag, two distinct VFOs", "", a14200, a14200, b14205, "A", pmSplitOff, false, a14200, 0, false},
{"ON flag but VFOs on different bands", "", a14200, a14200, b21000, "AB", pmSplitOn, false, a14200, 0, false},
{"ON flag but both VFOs identical", "", a14200, a14200, a14200, "AB", pmSplitOn, false, a14200, 0, false},
{"ON and OFF both set — ambiguous, treat as no split", "", a14200, a14200, b14205, "A", pmSplitOn | pmSplitOff, false, a14200, 0, false},
}
for _, c := range cases {
tx, rx, split := resolveOmniRigVFOs(c.rig, c.main, c.fa, c.fb, c.vfo, c.split, c.sticky)
if tx != c.wantTX || rx != c.wantRX || split != c.wantSplit {
t.Errorf("%s:\n got TX=%d RX=%d split=%v\n want TX=%d RX=%d split=%v",
c.name, tx, rx, split, c.wantTX, c.wantRX, c.wantSplit)
}
}
}
// Which VFO a frequency set writes to, and whether it may call SetSimplexMode.
//
// Reported on an FTDX101 (F4NBZ, 2026-07-29): listening on SUB, clicking a
// cluster spot dragged the radio back to MAIN. SetSimplexMode means "receive and
// transmit here, simplex" and OmniRig applies it to the MAIN VFO — so it must
// not be used when the operator is on SUB. They chose that VFO deliberately; a
// spot click asks for a frequency, not for a VFO change.
func TestOmniRigWriteTarget(t *testing.T) {
// Mirrors the decision made in SetFrequency.
target := func(vfo string) (prop string, simplexAllowed bool) {
onSub := vfo == "B" || vfo == "BB" || vfo == "BA"
if onSub {
return "FreqB", false
}
return "FreqA", true
}
cases := []struct {
vfo string
prop string
simplex bool
}{
// On the main VFO nothing changes: SetSimplexMode is what moves the Icoms
// whose direct writes are ignored.
{"", "FreqA", true},
{"A", "FreqA", true},
{"AA", "FreqA", true},
{"AB", "FreqA", true},
// On SUB, write FreqB and leave the VFO selection alone.
{"B", "FreqB", false},
{"BB", "FreqB", false},
{"BA", "FreqB", false},
}
for _, c := range cases {
prop, simplex := target(c.vfo)
if prop != c.prop || simplex != c.simplex {
t.Errorf("VFO %q → write %s, simplex=%v; want %s, simplex=%v",
c.vfo, prop, simplex, c.prop, c.simplex)
}
}
}