rouggy 6501e97895 fix: read the FIRST digit of the Yaesu VFO reply — I inverted it yesterday
Reported both ways round, which is what settles it. With RX and TX on SUB
everything worked; with them on MAIN the frequency froze and a spot click tuned
the sub VFO. The log shows the rig answering FR01 in the MAIN case.

So on an FTDX101 the state is the FIRST digit — 0 = main — and the second is a
separate parameter. Yesterday I changed this to the LAST digit, which read FR01
as SUB and inverted the whole thing. The fault that change was meant to fix ("SUB
shows MAIN") came from reading VS instead of FR, and probing FR had already fixed
it on its own; the digit change was an unnecessary guess layered on a real fix.

Nothing else needed changing for the operator's two questions: the display and
SetFrequency already follow curVFO, so a spot now tunes whichever VFO holds RX
and TX, and the main frequency is read when on main. A test states that in those
terms — active VFO and which command a spot writes — rather than only as a byte,
because the byte is what I got wrong while believing the logic was right.