rouggy 84b06ed47b fix: padlocks unclickable, From-radio level inert, callsign field too narrow
Padlocks. LockBtn was declared INSIDE the App component, so every render gave
React a new component type and the button was unmounted and rebuilt — about four
times a second while the CAT polls. It flickered under the pointer and swallowed
clicks, because the node being clicked no longer existed when the click landed.
The padlock now lives at module level and is passed its state.

From-radio level. It reached the QSO recorder and nothing else, so an operator
listening through OpsLog heard no difference between 10% and 150% — the control
was not weak, it was disconnected. It now scales the monitor too, applied on the
captured chunk so the network-fed path keeps its own levels, and a running
monitor picks up a change immediately: making someone restart the monitor to
hear the slider is how a working control gets reported as broken.

Callsign field widened to w-56, the room coming from the RST pair which never
needs more than five characters. It is the one field always typed into, it
carries the REC badges, and a long portable call has to stay readable.