The amplifier PUSHES status frames ("S0|state=…") on the same socket it answers
commands on, and it pushes them constantly once in OPERATE - power, SWR and
temperature all move while transmitting.

command() read exactly one line and took whatever arrived first as its answer.
One pushed frame therefore put the stream permanently one reply behind: every
later command read the PREVIOUS command's answer, and eventually one waited out
the 3 s deadline, failed, and dropped the connection. Hence a fresh TCP
connection and a fresh authentication every few seconds in the log.

The stall in transmit is the same defect seen from the other side: command()
holds the connection mutex across that whole dead wait, so SetOperate and every
other control queued behind up to three seconds of nothing.

It only appeared remotely and in OPERATE because that is when there is anything
to push - on a LAN with an idle amplifier the race hardly ever opens. Which is
why it did not do this yesterday.

readReplyLocked now reads until the R<id>| that belongs to the command, feeding
every frame it passes to parse() on the way - a pushed status is fresher than
the one we were about to ask for, so nothing is wasted.

authLocked used the same one-line read and worked around this by re-sending the
whole handshake, which is visible in the log as "auth reply=S0|state=IDLE
(try 1)" followed by a second attempt. It goes through the same reader now.