Files
OpsLog/internal/cat/omnirig.go
T
2026-07-26 16:57:19 +02:00

621 lines
24 KiB
Go

package cat
import (
"fmt"
"strings"
"time"
"github.com/go-ole/go-ole"
"github.com/go-ole/go-ole/oleutil"
)
// OmniRig Split is an enum, not a boolean: PM_SPLITON vs PM_SPLITOFF — both
// non-zero, so it must be compared to PM_SPLITON (testing "!= 0" reads OFF as
// split). Values confirmed empirically from real rigs (FT-710, SmartSDR):
// split ON = 0x8000, split OFF = 0x10000.
const (
pmSplitOn = 0x8000 // PM_SPLITON
pmSplitOff = 0x10000 // PM_SPLITOFF
)
// OmniRig talks to the user's installed OmniRig server over COM.
//
// All methods MUST be called from the same OS thread (the one Manager.run
// locks). COM is thread-affine on Windows — calling these from random
// goroutines will return E_FAIL or crash.
//
// The user must install OmniRig separately and configure their rig (COM port,
// baud rate) in OmniRig's own GUI. HamLog just reads/writes through it.
type OmniRig struct {
RigNum int // 1 (Rig1) or 2 (Rig2)
omnirig *ole.IDispatch
rig *ole.IDispatch
lastSig string // last logged Split/VFO signature — only log on change
rigType string // OmniRig's RigType string (the .ini title), e.g. "IC-7610"
// connLogged holds the connect failure already written to the log, so the
// 5-second reconnect loop reports a persistent problem once instead of
// forever. Cleared on success.
connLogged string
// lastSetFreq is the frequency most recently COMMANDED via SetFrequency.
// SetMode uses it to pick USB vs LSB for "SSB" instead of reading OmniRig's
// async Freq property, which still reports the OLD band for a poll or two
// after a QSY — that lag is why a clicked spot needed a second click to fix
// the sideband (freq moved, but mode read the old band → wrong sideband).
lastSetFreq int64
lastSetFreqAt time.Time
}
// NewOmniRig creates a non-connected backend. Call Connect before use.
func NewOmniRig(rigNum int) *OmniRig {
if rigNum < 1 || rigNum > 2 {
rigNum = 1
}
return &OmniRig{RigNum: rigNum}
}
func (o *OmniRig) Name() string { return "omnirig" }
// elevationHint recognises the COM refusal that happens when OmniRig runs
// elevated (as administrator) and OpsLog does not — or the reverse. Windows keeps
// the two integrity levels apart, so the client cannot bind to the running
// server's object and COM falls back to launching a fresh one, which then needs
// elevation the client cannot grant.
//
// It is worth naming explicitly: the operator SEES OmniRig running, with its
// settings window open, so "OmniRig not found" reads as nonsense and sends them
// hunting for a driver or COM-port problem that does not exist. The fix is thirty
// seconds of work once you know what to look for.
func elevationHint(err error) string {
if err == nil {
return ""
}
msg := strings.ToLower(err.Error())
// Matched on the HRESULT text in whatever language Windows is running in, so
// the code is checked too: 0x800702E4 = ERROR_ELEVATION_REQUIRED.
if strings.Contains(msg, "elevation") || strings.Contains(msg, "élévation") ||
strings.Contains(msg, "0x800702e4") || strings.Contains(msg, "access denied") ||
strings.Contains(msg, "accès refusé") {
return "OmniRig and OpsLog are running at different privilege levels — Windows keeps them apart, " +
"so OpsLog cannot reach OmniRig even though it is running. Start BOTH the same way: either " +
"un-tick \"Run as administrator\" on the OmniRig shortcut (and its Compatibility tab), or run " +
"OpsLog as administrator too"
}
return ""
}
// logConnFailure writes a connect failure once per distinct cause. The reconnect
// loop retries every 5 seconds forever, and a station whose OmniRig was simply
// elevated had this filling its log at roughly 1500 lines an hour — which buries
// the very diagnostics someone would go looking for.
func (o *OmniRig) logConnFailure(msg string) {
if o.connLogged == msg {
return
}
o.connLogged = msg
debugLog.Printf("OmniRig Rig%d: %s", o.RigNum, msg)
}
func (o *OmniRig) Connect() error {
// This used to announce DebugLogPath() on every attempt — the path of the
// FALLBACK cat.log, which nothing writes to once the app has wired LogSink and
// everything goes to data\opslog.log. It pointed operators at an empty file in
// %APPDATA% while the lines they wanted were somewhere else entirely. Dropped;
// and logged once per failure run rather than every 5-second retry.
if o.connLogged == "" {
debugLog.Printf("OmniRig.Connect Rig%d", o.RigNum)
}
if err := ole.CoInitializeEx(0, ole.COINIT_APARTMENTTHREADED); err != nil {
// 0x1 = S_FALSE → COM already initialised on this thread, fine.
if oerr, ok := err.(*ole.OleError); !ok || oerr.Code() != 0x00000001 {
return fmt.Errorf("CoInitializeEx: %w", err)
}
}
const progID = "Omnirig.OmnirigX"
var omnirig *ole.IDispatch
unk, err := oleutil.CreateObject(progID)
if err == nil {
omnirig, err = unk.QueryInterface(ole.IID_IDispatch)
unk.Release()
if err != nil {
return fmt.Errorf("query interface: %w", err)
}
} else {
// A privilege mismatch is final — retrying, or trying the 32-bit server,
// cannot cross an integrity boundary. Say what to do instead of dressing it
// up as "not installed", which is what sends operators looking in the wrong
// place entirely.
if hint := elevationHint(err); hint != "" {
o.logConnFailure(hint)
return fmt.Errorf("%s (Windows said: %v)", hint, err)
}
// Otherwise it may be a partial registration; try activating the 32-bit
// server explicitly before giving up (see omnirig_activate32.go).
disp, err32 := createOmniRig32(progID)
if err32 != nil {
o.logConnFailure(fmt.Sprintf("CreateObject(%s) failed: %v; 32-bit activation also failed: %v", progID, err, err32))
// Name the version requirement. HB9RYZ's OmniRig v2.1 is a different
// product that its own author states is not compatible with v1, and it
// does not provide v1's IOmniRigX interface — so an operator who has
// only v2 installed sees OmniRig running and OpsLog failing, with
// nothing to connect the two facts.
return fmt.Errorf("OmniRig (v1) not reachable: %w — OpsLog needs OmniRig v1.19/v1.20 "+
"(VE3NEA/Alex), the interface every logger uses. HB9RYZ's OmniRig v2.1 is a separate, "+
"incompatible product and cannot serve OpsLog; the two may be installed side by side, "+
"but v1 must be present and running", err)
}
debugLog.Printf("OmniRig: reached via explicit 32-bit activation after CreateObject failed (%v)", err)
omnirig = disp
}
o.connLogged = "" // connected: re-arm the one-shot failure logging
rigVar, err := oleutil.GetProperty(omnirig, fmt.Sprintf("Rig%d", o.RigNum))
if err != nil {
omnirig.Release()
return fmt.Errorf("get Rig%d: %w", o.RigNum, err)
}
o.omnirig = omnirig
o.rig = rigVar.ToIDispatch()
// Log WHICH OmniRig answered. There are two incompatible products called
// OmniRig: v1.19/1.20 (Alex, VE3NEA), whose IOmniRigX interface every logger
// including OpsLog uses, and HB9RYZ's v2.1, which its own author states is "not
// compatible" with v1 and works only with programs written for it. They can
// coexist, and OmniRig's own window looks much the same either way — so an
// operator running only v2 sees OmniRig on screen, sees OpsLog fail, and has no
// way to know the two were never going to talk. These two version numbers
// settle it in one line of a bug report.
var iv, sv int64 = -1, -1
if v, err := oleutil.GetProperty(o.omnirig, "InterfaceVersion"); err == nil {
iv = v.Val
}
if v, err := oleutil.GetProperty(o.omnirig, "SoftwareVersion"); err == nil {
sv = v.Val
}
if rt, err := oleutil.GetProperty(o.rig, "RigType"); err == nil {
o.rigType = rt.ToString()
}
debugLog.Printf("OmniRig connected: Rig%d type=%q (OmniRig interface=%d software=%d)",
o.RigNum, o.rigType, iv, sv)
return nil
}
func (o *OmniRig) Disconnect() {
if o.rig != nil {
o.rig.Release()
o.rig = nil
}
if o.omnirig != nil {
o.omnirig.Release()
o.omnirig = nil
}
ole.CoUninitialize()
}
func (o *OmniRig) ReadState() (RigState, error) {
if o.rig == nil {
return RigState{}, fmt.Errorf("not connected")
}
var s RigState
s.Backend = o.Name()
s.RigNum = o.RigNum
// Status: 0 = NOTCONFIGURED, 1 = DISABLED, 2 = PORTBUSY,
// 3 = NOTRESPONDING, 4 = ONLINE.
if statusVar, err := oleutil.GetProperty(o.rig, "Status"); err == nil {
s.Connected = statusVar.Val == 4
}
if rigTypeVar, err := oleutil.GetProperty(o.rig, "RigType"); err == nil {
s.Rig = rigTypeVar.ToString()
}
if !s.Connected {
// Status string from OmniRig is informative for the user.
if statusStrVar, err := oleutil.GetProperty(o.rig, "StatusStr"); err == nil {
s.Error = statusStrVar.ToString()
}
return s, nil
}
if modeVar, err := oleutil.GetProperty(o.rig, "Mode"); err == nil {
s.Mode = omniRigMode(modeVar.Val)
}
rawVfo := int64(0)
if vfoVar, err := oleutil.GetProperty(o.rig, "Vfo"); err == nil {
rawVfo = vfoVar.Val
s.Vfo = omniRigVfo(vfoVar.Val)
}
// Read the active/displayed frequency (generic Freq) AND both VFOs. The
// generic Freq is what the rig is operating on — the reliable source for the
// main/TX frequency. FreqA/FreqB are only needed to expose a genuine split.
freqMain, freqA, freqB := int64(0), int64(0), int64(0)
if v, err := oleutil.GetProperty(o.rig, "Freq"); err == nil {
freqMain = v.Val
}
if v, err := oleutil.GetProperty(o.rig, "FreqA"); err == nil {
freqA = v.Val
}
if v, err := oleutil.GetProperty(o.rig, "FreqB"); err == nil {
freqB = v.Val
}
// Split is an enum (PM_SPLITON / PM_SPLITOFF) — both non-zero, so it must be
// compared to PM_SPLITON, not "!= 0".
splitRaw := int64(0)
if v, err := oleutil.GetProperty(o.rig, "Split"); err == nil {
splitRaw = v.Val
}
// Diagnostic logged ONLY when Split or VFO changes (not on a timer), so
// normal operation stays quiet but toggling split on the radio is captured —
// needed to pin down this rig's PM_SPLITON value.
if sig := fmt.Sprintf("%x:%x", splitRaw, rawVfo); sig != o.lastSig {
o.lastSig = sig
debugLog.Printf("OmniRig Rig%d raw: Freq=%d FreqA=%d FreqB=%d Vfo=%q(raw=0x%X) Split=0x%X status=%d",
o.RigNum, freqMain, freqA, freqB, s.Vfo, rawVfo, splitRaw, func() int64 {
if v, e := oleutil.GetProperty(o.rig, "Status"); e == nil {
return v.Val
}
return -1
}())
}
s.FreqHz, s.RxFreqHz, s.Split = resolveOmniRigVFOs(freqMain, freqA, freqB, s.Vfo, splitRaw)
return s, nil
}
// resolveOmniRigVFOs turns OmniRig's four readings into the ADIF pair
// (FreqHz = TX, RxFreqHz = RX) plus a split flag.
//
// Pure and separate from ReadState because it encodes rig-specific rules that
// contradict each other — what fixes a Yaesu can break an Icom — and the only way
// to change it safely is with every known rig's behaviour pinned in a test. COM
// cannot be exercised from a test; this can.
func resolveOmniRigVFOs(freqMain, freqA, freqB int64, vfo string, splitRaw int64) (txHz, rxHz int64, split bool) {
// PM_SPLITON is tested as a BIT, not by equality. OmniRig's Split is a flag
// word: an exact `== 0x8000` holds only for a rig whose ini sets that bit and
// nothing else, and silently reports "no split" for any rig reporting the bit
// alongside another. Requiring ON set and OFF clear keeps the two states apart
// (both flags are non-zero, so a bare `!= 0` would read OFF as split) while
// tolerating extra bits.
splitFlagged := splitRaw&pmSplitOn != 0 && splitRaw&pmSplitOff == 0
// A genuine split also needs two distinct, non-zero VFOs in the SAME band. The
// band test kills the common false positive where VFO B merely holds a
// leftover from another band (a "28 MHz / 7 MHz split" is nonsensical), which
// on the FT-710 / TS-570 otherwise froze the TX freq on the wrong VFO.
if splitFlagged && freqA != 0 && freqB != 0 && freqA != freqB &&
BandFromHz(freqA) == BandFromHz(freqB) {
// RX is the VFO being listened on — identified from the generic Freq rather
// than from the Vfo AB/BA enum, which several rigs (Yaesu FTDX10) report
// inverted, showing TX and RX swapped.
switch {
case freqMain != 0 && freqMain == freqA:
return freqB, freqA, true // listening on A → TX on B
case freqMain != 0 && freqMain == freqB:
return freqA, freqB, true // listening on B → TX on A
case vfo == "BA":
return freqA, freqB, true // fall back to the Vfo enum
default:
return freqB, freqA, true
}
}
// Simplex. The VFO the rig says is ACTIVE comes first: preferring freqA
// unconditionally (as this did) meant the displayed frequency never left VFO
// A — press SUB VFO on an FTDX101D and the radio receives on B while OpsLog
// went on showing A, taking the band and the logged frequency with it.
//
// Only a VFO OmniRig explicitly names is honoured, so a rig that does not
// report the enum keeps exactly the previous fallback order. That matters for
// the IC-7610, whose stock ini reports the generic Freq as VFO B; and for the
// PM_FREQA rigs (Yaesu, Kenwood) versus the Icoms (IC-9100) that populate only
// the generic Freq.
switch {
case (vfo == "B" || vfo == "BB") && freqB != 0:
return freqB, 0, false
case (vfo == "A" || vfo == "AA") && freqA != 0:
return freqA, 0, false
case freqA != 0:
return freqA, 0, false
case freqMain != 0:
return freqMain, 0, false
default:
return freqB, 0, false
}
}
func (o *OmniRig) SetFrequency(hz int64) error {
if o.rig == nil {
debugLog.Printf("OmniRig.SetFrequency(%d): NOT CONNECTED", hz)
return fmt.Errorf("not connected")
}
// OmniRig Freq is a Long (int32). Validate to avoid silent truncation.
if hz < 0 || hz > 0x7fffffff {
debugLog.Printf("OmniRig.SetFrequency(%d): out of int32 range", hz)
return fmt.Errorf("frequency out of OmniRig int32 range")
}
hz32 := int32(hz)
// Remember the commanded frequency so a mode change moments later (a clicked
// spot sets freq then mode) picks the sideband from the TARGET band, not the
// not-yet-updated OmniRig Freq property.
o.lastSetFreq, o.lastSetFreqAt = hz, time.Now()
// Log the rig's writable-params, status and VFO state up front so a
// friend's session shows exactly what OmniRig reports for their rig.
status, statusStr, rigType := int64(-1), "", ""
if v, err := oleutil.GetProperty(o.rig, "Status"); err == nil {
status = v.Val
}
if v, err := oleutil.GetProperty(o.rig, "StatusStr"); err == nil {
statusStr = v.ToString()
}
if v, err := oleutil.GetProperty(o.rig, "RigType"); err == nil {
rigType = v.ToString()
}
rawVfo, vfo := int64(-1), ""
if vfoVar, err := oleutil.GetProperty(o.rig, "Vfo"); err == nil {
rawVfo = vfoVar.Val
vfo = omniRigVfo(vfoVar.Val)
} else {
debugLog.Printf("OmniRig.SetFrequency: Vfo read error: %v", err)
}
split := int64(0)
if v, err := oleutil.GetProperty(o.rig, "Split"); err == nil {
split = v.Val
}
// What can this rig's .ini actually write? OmniRig exposes a WriteableParams
// bitmask — if FreqA/FreqB/Freq bits are missing, the write is a silent no-op.
writeable := int64(-1)
if v, err := oleutil.GetProperty(o.rig, "WriteableParams"); err == nil {
writeable = v.Val
}
debugLog.Printf("OmniRig.SetFrequency(%d Hz / %.6f MHz): rig=%q status=%d(%s) vfo=%q(raw=%d) split=%d writeableParams=0x%X",
hz, float64(hz)/1e6, rigType, status, statusStr, vfo, rawVfo, split, writeable)
// Primary path: OmniRig's SetSimplexMode is the rig-agnostic "QSY here"
// method (RX=TX=freq, simplex). It works on rigs — notably Icom (IC-9100) —
// where direct FreqA/FreqB writes are accepted but never move the radio.
// Clearing split is the right thing when tuning to a spot anyway.
simplexOK := false
if _, err := oleutil.CallMethod(o.rig, "SetSimplexMode", int32(hz32)); err == nil {
simplexOK = true
debugLog.Printf("OmniRig.SetFrequency: SetSimplexMode(%d) OK", hz32)
} else {
debugLog.Printf("OmniRig.SetFrequency: SetSimplexMode unavailable (%v)", err)
}
// On Yaesu / Kenwood (and anything non-Icom), SetSimplexMode frequently returns
// OK but is a SILENT NO-OP — the rig never moves. Confirmed on an FT-891 over
// OmniRig: every spot click logged "SetSimplexMode OK" yet FreqA stayed put,
// while SetMode on the same .ini worked fine (so the CAT link is healthy).
// Writing the VFO frequency PROPERTY directly DOES move them, so also do that
// here. It is skipped on Icom, where the direct write is the unreliable one and
// could nudge the wrong Main/Sub VFO — there SetSimplexMode is authoritative.
isIcom := strings.HasPrefix(strings.ToUpper(strings.TrimSpace(rigType)), "IC")
if !isIcom || !simplexOK {
prop := "FreqA"
switch vfo {
case "B", "BB", "BA":
prop = "FreqB"
}
okAny := false
for _, p := range []string{prop, "Freq"} {
if _, e := oleutil.PutProperty(o.rig, p, hz32); e != nil {
debugLog.Printf("OmniRig.SetFrequency: PutProperty(%s) error: %v", p, e)
} else {
debugLog.Printf("OmniRig.SetFrequency: PutProperty(%s, %d) OK", p, hz32)
okAny = true
}
}
if !simplexOK && !okAny {
return fmt.Errorf("OmniRig: no writable frequency property for this rig")
}
}
// Read back all three immediately. OmniRig is async (the CAT command is
// queued + sent over serial), so these may still show the OLD value for
// one poll cycle — but if they NEVER change in the next poll, the rig
// isn't honouring the write (wrong .ini WRITE command for this model).
fa, fb, fg := int64(-1), int64(-1), int64(-1)
if v, err := oleutil.GetProperty(o.rig, "FreqA"); err == nil {
fa = v.Val
}
if v, err := oleutil.GetProperty(o.rig, "FreqB"); err == nil {
fb = v.Val
}
if v, err := oleutil.GetProperty(o.rig, "Freq"); err == nil {
fg = v.Val
}
debugLog.Printf("OmniRig.SetFrequency: readback FreqA=%d FreqB=%d Freq=%d (target %d)", fa, fb, fg, hz)
return nil
}
// SetMode maps an ADIF mode to the OmniRig PM_* bit and pushes it to the rig.
// For SSB, the USB/LSB side is chosen from the rig's current frequency
// following worldwide convention (LSB below 14 MHz, USB above).
//
// IMPORTANT: OmniRig's Mode property is typed as Long (VT_I4). go-ole would
// otherwise wrap a Go int64 into a VT_I8 variant which COM marshalling can
// reject silently or misinterpret — passing the wrong bit. Always cast to
// int32 explicitly.
//
// Logs each call to stdout so the user can cross-check what HamLog sent
// against OmniRig's Monitor window (right-click systray → Monitor) to find
// rig-specific mismatches (e.g. a Kenwood without FM on HF, an .ini with the
// wrong CAT command for a mode, etc.).
func (o *OmniRig) SetMode(mode string) error {
if o.rig == nil {
return fmt.Errorf("not connected")
}
var (
bit int64
bitName string
)
switch strings.ToUpper(strings.TrimSpace(mode)) {
case "CW":
bit, bitName = pmCWU, "PM_CW_U"
case "SSB":
// Decide USB vs LSB from the frequency. Prefer the freq we just COMMANDED
// (a clicked spot sets freq then mode ~150ms later): OmniRig's Freq
// property still reports the OLD band for a poll or two after a QSY, so
// reading it here picked the wrong sideband and the user had to click a
// second time. Fall back to the live read for a standalone mode change.
var freq int64
if o.lastSetFreq > 0 && time.Since(o.lastSetFreqAt) < 5*time.Second {
freq = o.lastSetFreq
} else if freqVar, err := oleutil.GetProperty(o.rig, "Freq"); err == nil {
freq = freqVar.Val
}
if freq > 0 && freq < 10_000_000 {
bit, bitName = pmSSBL, "PM_SSB_L"
} else {
bit, bitName = pmSSBU, "PM_SSB_U"
}
case "AM":
bit, bitName = pmAM, "PM_AM"
case "FM":
bit, bitName = pmFM, "PM_FM"
case "RTTY", "FSK":
// OmniRig has no specific RTTY/FSK mode — falls back to generic
// digital USB. Many rigs need RTTY selected manually on the panel.
bit, bitName = pmDIGU, "PM_DIG_U"
case "FT8", "FT4", "PSK31", "MFSK", "JS8", "JT65", "JT9", "OLIVIA", "DIGITALVOICE", "DATA":
bit, bitName = pmDIGU, "PM_DIG_U"
default:
return fmt.Errorf("OmniRig: unsupported mode %q", mode)
}
debugLog.Printf("OmniRig.SetMode(%q) → %s = 0x%08X (%d)", mode, bitName, bit, bit)
_, err := oleutil.PutProperty(o.rig, "Mode", int32(bit))
if err != nil {
debugLog.Printf("OmniRig.SetMode error: %v", err)
return fmt.Errorf("SetMode(%s) → %s: %w", mode, bitName, err)
}
// Read back what OmniRig now thinks the rig is on (best-effort —
// OmniRig is async so this may still be the old value for one poll).
if mv, err := oleutil.GetProperty(o.rig, "Mode"); err == nil {
debugLog.Printf("OmniRig.Mode immediately after Put = 0x%08X (%d) → %s",
mv.Val, mv.Val, omniRigMode(mv.Val))
}
return nil
}
// SetPTT keys or unkeys the rig via OmniRig's SetTx(PM_RX|PM_TX). Used by the
// Digital Voice Keyer to put the rig into TX while a voice message plays.
func (o *OmniRig) SetPTT(on bool) error {
if o.rig == nil {
debugLog.Printf("OmniRig.SetPTT(%v): NOT CONNECTED", on)
return fmt.Errorf("not connected")
}
status, statusStr, writeable := int64(-1), "", int64(-1)
if v, err := oleutil.GetProperty(o.rig, "Status"); err == nil {
status = v.Val
}
if v, err := oleutil.GetProperty(o.rig, "StatusStr"); err == nil {
statusStr = v.ToString()
}
if v, err := oleutil.GetProperty(o.rig, "WriteableParams"); err == nil {
writeable = v.Val
}
txWriteable := writeable != -1 && writeable&pmTX != 0
param, name := pmRX, "PM_RX"
if on {
param, name = pmTX, "PM_TX"
}
debugLog.Printf("OmniRig.SetPTT(%v): status=%d(%s) writeableParams=0x%X PM_TX-writeable=%v → Tx=%s",
on, status, statusStr, writeable, txWriteable, name)
// When OmniRig DID report its writeable params (writeable != -1) and PM_TX
// is NOT among them, writing Tx is a silent no-op: the rig never keys and
// SetPTT would otherwise return success, leaving the user puzzled ("Test PTT
// does nothing"). Surface a clear, actionable error instead. If we couldn't
// read the writeable params (-1), fall through and try anyway (best effort).
if on && writeable != -1 && writeable&pmTX == 0 {
debugLog.Printf("OmniRig.SetPTT: ⚠ PM_TX not writeable for this rig profile (writeableParams=0x%X)", writeable)
return fmt.Errorf("this rig's OmniRig profile doesn't expose CAT TX keying (PM_TX not writeable) — use RTS/DTR or VOX for PTT")
}
// OmniRig has NO SetTx method (that returns "unknown name"); the Tx
// parameter is set via the writeable Tx PROPERTY (PM_TX / PM_RX).
if _, err := oleutil.PutProperty(o.rig, "Tx", int32(param)); err != nil {
debugLog.Printf("OmniRig.SetPTT error: %v", err)
return fmt.Errorf("set Tx=%s: %w", name, err)
}
// Read the Tx param straight back. OmniRig is async — this may still show the
// previous value for a poll cycle — but if a key/unkey NEVER changes it, the
// write was coalesced or the rig isn't honouring PM_TX/PM_RX (wrong .ini).
if v, err := oleutil.GetProperty(o.rig, "Tx"); err == nil {
txState := "PM_RX"
if v.Val&pmTX != 0 {
txState = "PM_TX"
}
debugLog.Printf("OmniRig.SetPTT: Tx readback = 0x%X (%s)", v.Val, txState)
}
return nil
}
// ===== OmniRig enum decoders =====
// Bit flags from OmniRig type library (RigParamX enum in OmniRig_TLB.pas).
//
// Cross-checked against https://github.com/VE3NEA/OmniRig — be careful when
// referencing other people's writeups online, several have these one bit
// too low which causes every mode to map to the slot below it (AM → DIG_L,
// FT8 → SSB_L, etc.).
const (
pmRX int64 = 1 << 20 // 0x00100000 — PM_RX (receive)
pmTX int64 = 1 << 21 // 0x00200000 — PM_TX (transmit / PTT on)
pmCWU int64 = 1 << 23 // 0x00800000
pmCWL int64 = 1 << 24 // 0x01000000
pmSSBU int64 = 1 << 25 // 0x02000000
pmSSBL int64 = 1 << 26 // 0x04000000
pmDIGU int64 = 1 << 27 // 0x08000000
pmDIGL int64 = 1 << 28 // 0x10000000
pmAM int64 = 1 << 29 // 0x20000000
pmFM int64 = 1 << 30 // 0x40000000 — still fits in int32 (max 2^31-1)
)
// omniRigMode maps the OmniRig Mode bit-flag to an ADIF mode string.
// OmniRig only reports rough categories; specific digital modes
// (FT8, RTTY, PSK31…) can't be inferred — DATA is returned and the user
// can keep / override the mode they already had in the entry form.
func omniRigMode(m int64) string {
switch {
case m&(pmCWU|pmCWL) != 0:
return "CW"
case m&(pmSSBU|pmSSBL) != 0:
return "SSB"
case m&(pmDIGU|pmDIGL) != 0:
return "DATA"
case m&pmAM != 0:
return "AM"
case m&pmFM != 0:
return "FM"
}
return ""
}
// omniRigVfo maps the OmniRig Vfo RigParamX enum to a short label, using the
// documented PM_VFO* constants.
func omniRigVfo(v int64) string {
switch {
case v&0x40 != 0: // PM_VFOAA
return "AA"
case v&0x80 != 0: // PM_VFOAB
return "AB"
case v&0x100 != 0: // PM_VFOBA
return "BA"
case v&0x200 != 0: // PM_VFOBB
return "BB"
case v&0x400 != 0: // PM_VFOA
return "A"
case v&0x800 != 0: // PM_VFOB
return "B"
}
return ""
}