"version": "0.20.8",
"date": "2026-07-21",
"en": [
"New: microHAM ARCO rotator controlled natively — no PstRotator needed. Over the LAN or over USB: set the ARCO's CONTROL PROTOCOL (LAN or USB) to 'Yaesu GS-232A' and pick 'microHAM ARCO' in Settings → Rotator.",
"Amplifier without a FlexRadio: the amplifier controls (OPERATE/STANDBY, ON/OFF, live power/SWR/temperature) now also live in the Station Control tab, and a status chip sits in the bottom bar next to Cluster/CAT/Rotator — green ON AIR = OPERATE, orange = STANDBY, red = offline. Clicking the chip toggles OPERATE/STANDBY on all three amps (PowerGenius XL included, over its direct network link).",
"NET Control: after logging a station, the next on-air station is selected automatically (chain log → log → log), and a new 'Log everyone' button logs every on-air station at once when the net ends.",
"Switching to a profile whose MySQL database is unreachable now shows a clear warning — before, OpsLog silently stayed on the previous logbook and QSOs could land in the wrong log.",
"The ON AIR badge is back for local (SQLite) logbooks — it had disappeared with the removal of the live-status option."
],
"fr": [
"Nouveau : rotator microHAM ARCO contrôlé en natif — sans PstRotator. Par le réseau ou par USB : régler le CONTROL PROTOCOL de l'ARCO (LAN ou USB) sur « Yaesu GS-232A » et choisir « microHAM ARCO » dans Réglages → Rotator.",
"Amplificateur sans FlexRadio : les commandes d'ampli (OPERATE/STANDBY, ON/OFF, puissance/ROS/température en direct) sont maintenant aussi dans l'onglet Station Control, et une pastille de statut s'affiche dans la barre du bas à côté de Cluster/CAT/Rotator — vert = OPERATE, orange = STANDBY, rouge = hors ligne. Un clic sur la pastille bascule OPERATE/STANDBY sur les trois amplis (PowerGenius XL compris, via son lien réseau direct).",
"NET Control : après avoir loggé une station, la station on air suivante est sélectionnée automatiquement (enchaînement log → log → log), et un nouveau bouton « Logger tout le monde » enregistre toutes les stations on air d'un coup à la fin du net.",
"Passer sur un profil dont la base MySQL est injoignable affiche maintenant un avertissement clair — avant, OpsLog restait silencieusement sur l'ancien logbook et les QSO pouvaient partir dans le mauvais log.",
"Le badge ON AIR est de retour pour les logbooks locaux (SQLite) — il avait disparu avec la suppression de l'option de statut en direct."
]
},
{
"version": "0.20.7",
"date": "2026-07-21",
"en": [
"New: ACOM amplifier support (500S / 600S / 700S / 1200S / 2020S) — OPERATE/STANDBY/OFF, live telemetry (power, SWR, PA temperature, band, fan) in Settings and the radio panel, over USB serial or an RS232-to-Ethernet bridge. Power-ON works over serial when the cable wires the DTR/RTS pins. The Amplifier settings now pick Brand then Model.",
"Multi-operator live sync fixed: the shared-MySQL connection pool was too small, so after a while the grid, chat and 'stations on air' silently stopped updating. The pool is now sized for real multi-op use (with 5 operators it stays well within a max_connections=300 server).",
"Live operator status is now always published on a shared MySQL logbook — the Settings toggle is gone. You still go off-air automatically 5 minutes after your last QSO, and the 'stations on air' panel refreshes noticeably faster (a redundant table check on every read was removed).",
"The By-Continent statistics donut now totals the same as your QSO count — QSOs whose continent couldn't be resolved are shown as an 'Unknown' slice instead of being dropped (the Continents count still lists only real continents)."
],
"fr": [
"Nouveau : prise en charge des amplificateurs ACOM (500S / 600S / 700S / 1200S / 2020S) — OPERATE/STANDBY/OFF, télémétrie en direct (puissance, ROS, température PA, bande, ventilateur) dans les Réglages et le panneau radio, en USB série ou via un pont RS232-vers-Ethernet. La mise en marche fonctionne en série si le câble relie les broches DTR/RTS. Les réglages Amplificateur se font maintenant par Marque puis Modèle.",
"Synchronisation multi-opérateurs corrigée : le pool de connexions MySQL partagé était trop petit, et au bout d'un moment la grille, le chat et « stations on air » cessaient silencieusement de se mettre à jour. Le pool est maintenant dimensionné pour un vrai multi-op (à 5 opérateurs, on reste largement sous un serveur à max_connections=300).",
"Le statut opérateur en direct est maintenant toujours publié sur un logbook MySQL partagé — l'option des Réglages a disparu. Vous passez toujours hors antenne automatiquement 5 minutes après votre dernier QSO, et le panneau « stations on air » se rafraîchit nettement plus vite (une vérification de table redondante à chaque lecture a été supprimée).",
"La donut « Par continent » des statistiques totalise maintenant le même nombre que le total de QSO — les QSO dont le continent n'a pas pu être résolu apparaissent dans un segment « Unknown » au lieu d'être ignorés (le compteur Continents ne liste toujours que les vrais continents)."
]
},
{
"version": "0.20.6",
"date": "2026-07-21",
"en": [
"Amplifier controls now live right in the FlexRadio panel: OPERATE/STANDBY, ON/OFF, Low/Mid/High power level, an output-power bar and live band / SWR / temperature — for both PowerGenius XL and SPE Expert. The card is hidden when no amplifier is selected.",
"Faster startup: the radio (CAT) connects immediately instead of waiting behind the shared-MySQL connection, and MySQL itself connects much faster.",
"No more lost QSOs: an FT8/MSHV QSO that can't reach a laggy shared database is parked and re-logged automatically once it recovers; simultaneous QSOs from a multi-stream are now queued instead of failing with 'too many requests'.",
"The 'stations on air' widget now updates within a second of a QSO (it used to lag up to ~45s behind the ON-AIR badge).",
"Relay boards (Denkovi / USB-serial) stay connected reliably now, with a Test-connection button and detect feedback in the Station Control setup.",
"<LOGQSO> in a CW macro logs the contact at that exact point in the macro, and pressing ESC before it runs cancels the log.",
"Auto-call now waits exactly the gap you set between calls (it was waiting far longer).",
"Statistics: the redundant per-band chart was merged into the CW / phone / data split.",
"Cluster self-spot pop-ups now show the band.",
"The bottom status bar is no longer hidden behind a scrollbar in a small window.",
"Update check now also runs when you open Help - About, and every 5 minutes."
],
"fr": [
"Les commandes d'amplificateur sont maintenant directement dans le panneau FlexRadio : OPERATE/STANDBY, Marche/Arrêt, niveau Low/Mid/High, une barre de puissance de sortie et l'état en direct bande / ROS / température — pour PowerGenius XL comme pour SPE Expert. La carte est masquée si aucun ampli n'est sélectionné.",
"Démarrage plus rapide : la radio (CAT) se connecte immédiatement au lieu d'attendre derrière la connexion MySQL partagée, et MySQL lui-même se connecte bien plus vite.",
"Plus de QSO perdus : un QSO FT8/MSHV qui n'atteint pas une base partagée lente est mis de côté et ré-enregistré automatiquement dès qu'elle répond ; les QSO simultanés d'un multi-stream sont maintenant mis en file au lieu d'échouer avec « too many requests ».",
"Le widget « stations on air » se met à jour en une seconde après un QSO (il pouvait accuser jusqu'à ~45s de retard sur le badge ON AIR).",
"Les cartes relais (Denkovi / USB-série) restent connectées de façon fiable, avec un bouton « Tester la connexion » et un retour de détection dans la configuration Station Control.",
"<LOGQSO> dans une macro CW enregistre le contact à cet endroit précis de la macro, et appuyer sur ÉCHAP avant son exécution annule l'enregistrement.",
"L'appel automatique respecte maintenant exactement l'intervalle réglé entre les appels (il attendait bien plus longtemps).",
"Statistiques : le graphique par bande redondant a été fusionné avec la répartition CW / phone / data.",
"Les popups d'auto-spot du cluster affichent maintenant la bande.",
"La barre de statut du bas n'est plus masquée par une barre de défilement en fenêtre réduite.",
"La vérification de mise à jour se déclenche aussi à l'ouverture d'Aide - À propos, et toutes les 5 minutes."
]
},
{
"version": "0.20.5",
"date": "2026-07-20",
"en": [
"New FlexRadio CWX CW keyer: key CW straight over the SmartSDR connection — no WinKeyer or SmartCAT needed. Type-ahead and mid-send backspace supported.",
"ESC now stops CW on whichever keyer is active (WinKeyer / Icom / Flex), and typing a callsign aborts a running macro.",
"New Amplifier settings section (was 'Power Genius'): control SPE Expert amps (1.3K / 1.5K / 2K) over USB serial or an RS232-to-Ethernet bridge — OPERATE/STANDBY and live status. PowerGenius XL still supported.",
"Denkovi USB relay boards supported (4/8 relays, FT245), plus generic CH340/LCUS USB-serial relay boards.",
"Rename your database from Settings without losing any configuration.",
"Awards: DDFM now finds the French department from the address postal code; refs are stored on each QSO for faster columns; 'Publish to catalog' shares an edited award with your team on the next release; award columns are remembered per profile.",
"Statistics: per-band mode split (CW / phone / data), and an activity chart with a Day / Week / Month / Year selector (rolling, real dates).",
"'Stations on air' widget updates within seconds and fits more stations.",
"The audio CW decoder was removed.",
"Fixes: Antenna Genius buttons ignored clicks while a macro was sending; File → Exit; and more.",
"This 'What's new' summary now appears on the first launch after each update."
],
"fr": [
"Nouveau keyer CW FlexRadio CWX : manipulation CW directement via la connexion SmartSDR — plus besoin de WinKeyer ni de SmartCAT. Type-ahead et retour arrière en cours d'envoi supportés.",
"ESC arrête maintenant le CW sur le moteur actif (WinKeyer / Icom / Flex), et taper un indicatif interrompt une macro en cours.",
"Nouvelle section Amplificateur (ex « Power Genius ») : pilotage des SPE Expert (1.3K / 1.5K / 2K) en USB série ou via un pont RS232→Ethernet — OPERATE/STANDBY et état en direct. PowerGenius XL toujours supporté.",
"Cartes relais USB Denkovi (4/8 relais, FT245), plus cartes USB-série génériques CH340/LCUS.",
"Renommer sa base depuis les réglages sans perdre la configuration.",
"Awards : DDFM trouve le département français depuis le code postal de l'adresse ; les réfs sont stockées sur chaque QSO (colonnes plus rapides) ; « Publier au catalogue » partage un award édité avec l'équipe à la prochaine mise à jour ; les colonnes d'award sont mémorisées par profil.",
"Statistiques : répartition des modes par bande (CW / phone / data), et un graphe d'activité avec sélecteur Jour / Semaine / Mois / Année (glissant, dates réelles).",
"Le widget « Stations on air » se met à jour en quelques secondes et affiche plus de stations.",
"Le décodeur CW audio a été retiré.",
"Corrections : les boutons Antenna Genius ignoraient les clics pendant l'envoi d'une macro ; Fichier → Quitter ; et d'autres.",
"Ce résumé « Nouveautés » s'affiche désormais au premier lancement après chaque mise à jour."
]
}
]