rouggy b2eb6a4b1e fix(icom): the 7760 power meter interpolates between MEASURED anchors
A known 50 W read raw ~89 where the two-segment curve said 62: the face is
not linear in watts below half scale. Watts now interpolate through the
measured points (50 W, 100 W, full-scale 250 W); refining the curve is adding
a row to the table.