rouggy bd2edf6624 fix(icom): verify the data flag after a mode set, and correct it with 0x26
The IC-7760 acknowledges the 1A 06 data-mode command and stays in USB-D
anyway, which left the operator unable to get back to plain USB from the
console at all. After every mode set the flag is read back; on a mismatch it
is said again with 0x26 — mode, data flag and filter in one frame, the form
the newer rigs actually honour. Only on a mismatch, so rigs that predate 0x26
never see the command.