rouggy d62cd10478 fix(icom): switch off a leftover waveform stream at first contact
The 0x27 output flag lives in the RADIO and survives our sessions: a scope
enabled by an older build (or another program) kept flooding every new
session with 700-byte frames — and on the IC-7760 that flood is what kills
the CI-V link. One 'waveform output off' as soon as the rig answers, once per
session; the front-panel display is deliberately untouched.