rouggy 43095a1d89 feat(rigctld): split that actually reaches the radio, or an honest refusal
set_split_vfo and set_split_freq both answered RPRT 0 and did nothing. WSJT-X
and JTDX in "Split Operating: Rig" send exactly that pair, believed both, and
transmitted on the RECEIVE frequency — on a pileup, straight onto the DX, while
showing the operator precisely what they had asked for. A lie that leaves no
trace in any log is the worst kind of bug this program can have.

The two commands are honoured as a PAIR. Arming alone does nothing on the radio,
because WSJT-X sends the frequency second and split armed on whatever the
transmit VFO happened to hold is worse than no split at all: it transmits
somewhere the operator never chose. The request is remembered and set_split_freq
does the work.

Kenwood gains SetSplit — FB to place the dial, then FR0/FT1 to arm, in that
order for the same reason. It writes what State() already knows how to read.

Everything else REFUSES, and that is the feature, not a shortfall. Only Flex and
Icom could even toggle split before, neither could set the transmit frequency,
and Yaesu, TCI and OmniRig have nothing at all. A refusal WSJT-X can report —
and act on, by falling back to Fake It — is worth far more than a success it has
no way to check.

Both paths are pinned: split reaching the rig as one armed call with the right
frequency, and a backend that cannot do it producing an error rather than RPRT 0.
2026-08-11 17:53:46 +02:00

608 lines
20 KiB
Go
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
// Package rigctld shares OpsLog's CAT link with other programs.
//
// A native CAT backend owns the rig's serial port, and Windows gives a COM port
// to ONE process. So the moment OpsLog talks to the radio directly, WSJT-X,
// MSHV or JTDX can no longer reach it — the cost of dropping OmniRig, which was
// itself a sharing layer.
//
// The answer is the one wfview uses: OpsLog becomes the server. It speaks the
// Hamlib "net rigctl" protocol, which WSJT-X, JTDX, MSHV, Log4OM and CQRLOG all
// support natively (rig model "Hamlib NET rigctl", host:4532) with no driver to
// install. The other program asks us, and we relay to whichever backend is
// connected — OmniRig, Flex, Icom, TCI or Yaesu alike.
//
// ── The protocol ──────────────────────────────────────────────────────────
// Line-based ASCII. A lowercase letter reads, its uppercase counterpart writes,
// and long names are prefixed with a backslash. A write answers "RPRT 0" for
// success or "RPRT -n" for an error; a read answers the value(s), one per line.
//
// f → 14074000 get_freq
// F 14074000 → RPRT 0 set_freq
// m → USB\n2400 get_mode (mode + passband)
// M USB 2400 → RPRT 0 set_mode
// t / T 1 → 0 get/set PTT
// s → 0\nVFOB get_split_vfo
// v → VFOA get_vfo
// \dump_state → capability block asked once by WSJT-X at connect
//
// WSJT-X will not proceed past connect without a well-formed dump_state, which
// is why that block is written out in full rather than stubbed.
package rigctld
import (
"bufio"
"fmt"
"net"
"strconv"
"strings"
"sync"
"sync/atomic"
"time"
)
// Rig is what the server needs from OpsLog's CAT manager. An interface, so this
// package stays testable without a radio and without importing internal/cat.
type Rig interface {
Freq() int64 // current TX frequency in Hz, 0 if unknown
Mode() string // ADIF mode (SSB, CW, FT8…)
Split() (bool, int64) // split on?, and the other VFO's frequency
SetFreq(hz int64) error
SetMode(mode string) error
SetPTT(on bool) error
// SetSplit arms or clears split and places the transmit frequency. Returns an
// error on a rig that cannot: a refusal the client can report is worth far
// more than a success it has no way to check.
SetSplit(on bool, txHz int64) error
}
type Server struct {
port int
rig Rig
log func(string, ...any)
mu sync.Mutex
ln net.Listener
conns map[net.Conn]struct{}
closed bool
// accepted counts every connection this listener has taken. Only selfTest
// reads it, to tell "a client reached us" from "a client reached someone
// else on our port".
accepted atomic.Int64
// ptt mirrors the last PTT state a client commanded via set_ptt. WSJT-X/JTDX
// poll get_ptt DURING transmit to confirm the rig is keyed; if get_ptt reads
// RX they conclude PTT failed and abort the over after a second or two. We
// don't read PTT back from every backend, so echo what the client last set —
// always consistent with its own command, and enough to satisfy the check.
ptt atomic.Bool
// pttKnown says ptt reflects a state we actually commanded, so a repeat can
// be told from the very first call — where the radio's state is unknown and
// the command must go through.
pttKnown atomic.Bool
// splitWanted remembers a set_split_vfo that arrived before the frequency it
// needs, so the pair can be honoured in the order the client sends them.
splitWanted atomic.Bool
}
func New(port int, rig Rig, logf func(string, ...any)) *Server {
if port <= 0 || port > 65535 {
port = 4532 // the rigctld default every client pre-fills
}
if logf == nil {
logf = func(string, ...any) {}
}
return &Server{port: port, rig: rig, log: logf, conns: map[net.Conn]struct{}{}}
}
func (s *Server) Start() error {
s.mu.Lock()
if s.ln != nil {
s.mu.Unlock()
return nil // already listening
}
s.closed = false
s.mu.Unlock()
ln, err := net.Listen("tcp", fmt.Sprintf(":%d", s.port))
if err != nil {
return fmt.Errorf("rigctld: listen on %d: %w", s.port, err)
}
s.mu.Lock()
s.ln = ln
s.mu.Unlock()
s.log("rigctld: sharing CAT on port %d (Hamlib NET rigctl)", s.port)
go func() {
for {
c, err := ln.Accept()
if err != nil {
s.mu.Lock()
closed := s.closed
s.mu.Unlock()
if !closed {
s.log("rigctld: accept failed: %v", err)
}
return
}
s.accepted.Add(1)
s.mu.Lock()
s.conns[c] = struct{}{}
s.mu.Unlock()
go s.serve(c)
}
}()
go s.selfTest()
return nil
}
// selfTest checks that a client connecting to 127.0.0.1:<port> actually reaches
// THIS listener, and says so in the log when it does not.
//
// Binding successfully is not the same as being reachable. OpsLog listens on
// 0.0.0.0, and Windows lets a second program bind the SAME port on the specific
// address 127.0.0.1. Connections to localhost then go to the MORE SPECIFIC
// listener — the other program — while ours sits there having logged "sharing
// CAT on port 4532" and never seeing a single client.
//
// Seen in the field with Nexus, which starts its own rigctld on 127.0.0.1:4532
// and connects to it. Neither program reports anything wrong; the operator gets
// a CAT timeout from a daemon with no radio behind it, and OpsLog's log is
// silent because nothing ever arrived. Three exchanges went into finding that,
// so it is worth one line at startup.
//
// The counter can only be raised by our own accept loop, so a real client
// arriving during the probe makes this pass, never fail wrongly.
func (s *Server) selfTest() {
before := s.accepted.Load()
addr := fmt.Sprintf("127.0.0.1:%d", s.port)
c, err := net.DialTimeout("tcp", addr, 2*time.Second)
if err != nil {
s.log("rigctld: WARNING — could not reach our own CAT port at %s (%v); "+
"clients on this PC will not find OpsLog", addr, err)
return
}
defer c.Close()
// Give the accept loop a moment: the dial returns as soon as the handshake
// completes, which can be marginally before Accept hands the connection over.
for i := 0; i < 20; i++ {
if s.accepted.Load() > before {
return // it reached us — nothing to say
}
time.Sleep(50 * time.Millisecond)
}
s.log("rigctld: WARNING — another program is already answering on %s. "+
"It will receive the CAT connections meant for OpsLog, which will look "+
"like a timeout in that program and silence here. Close it, or move "+
"OpsLog's shared CAT to a different port.", addr)
}
// releasePTT drops the transmitter when whoever was holding it goes away.
//
// Nothing else will. The Kenwood/Elecraft backend deliberately suspends its
// wire poll while PTT is held (a K3 answers "?;" to IF; during transmit), so a
// client that crashes, is killed, or simply has its socket closed under it
// leaves the rig keyed with nobody watching — and closing the socket is exactly
// what Stop() does on every settings save. Seen in the field: a K3 sat in
// transmit for 29 s, until the CAT link happened to be rebuilt.
//
// Swap makes this once-only, so the Stop() path and the per-connection defer it
// triggers can both call it without double-unkeying.
func (s *Server) releasePTT(why string) {
if !s.ptt.Swap(false) {
return
}
s.log("rigctld: %s while the rig was keyed — dropping PTT", why)
if err := s.rig.SetPTT(false); err != nil {
s.log("rigctld: emergency unkey failed: %v", err)
}
}
func (s *Server) Stop() {
// Before anything is torn down: reloadCAT calls us BEFORE it restarts the CAT
// backend, so the rig is still reachable here and an unkey still lands.
s.releasePTT("CAT sharing stopped")
s.mu.Lock()
s.closed = true
ln := s.ln
s.ln = nil
conns := make([]net.Conn, 0, len(s.conns))
for c := range s.conns {
conns = append(conns, c)
}
s.conns = map[net.Conn]struct{}{}
s.mu.Unlock()
if ln != nil {
_ = ln.Close()
}
// Close the live sessions too. Leaving them open would keep a client happily
// talking to a server the operator has switched off.
for _, c := range conns {
_ = c.Close()
}
}
func (s *Server) serve(c net.Conn) {
defer func() {
s.mu.Lock()
delete(s.conns, c)
s.mu.Unlock()
_ = c.Close()
// A client that walks away mid-over must not leave the rig transmitting.
s.releasePTT(fmt.Sprintf("client %s left", c.RemoteAddr()))
}()
s.log("rigctld: client connected from %s", c.RemoteAddr())
r := bufio.NewReader(c)
w := bufio.NewWriter(c)
for {
// No deadline: WSJT-X polls every few seconds but a client may legitimately
// sit idle between band changes, and dropping it would look like a fault.
line, err := r.ReadString('\n')
if err != nil {
s.log("rigctld: client %s disconnected", c.RemoteAddr())
return
}
resp, quit := s.handle(strings.TrimSpace(line))
if resp != "" {
if _, err := w.WriteString(resp); err != nil {
return
}
if err := w.Flush(); err != nil {
return
}
}
if quit {
return
}
}
}
// handle answers one command line. Pure apart from the Rig calls, so the whole
// protocol is testable with a fake rig.
func (s *Server) handle(line string) (resp string, quit bool) {
if line == "" {
return "", false
}
// Extended mode: clients may prefix a command with '+' or '-' to ask for a
// verbose reply. We answer in the plain format, which every client also
// accepts, so the prefix is simply stripped.
line = strings.TrimLeft(line, "+-")
fields := strings.Fields(line)
if len(fields) == 0 {
return "", false
}
cmd, args := fields[0], stripVFOArg(fields[1:])
switch cmd {
case "\\dump_state", "dump_state":
return dumpState, false
case "\\chk_vfo", "chk_vfo":
// "is VFO mode on?" — we answer for one VFO at a time, so: no.
return "CHKVFO 0\n", false
case "\\get_powerstat", "get_powerstat":
return "1\n", false
// Three commands a client may issue as a matter of course. Refusing them with
// RPRT -11 is allowed, and a tolerant client carries on — but nothing obliges
// it to, and Nexus sends all three around every transmit. Answering costs
// nothing and removes them as suspects when something really is wrong.
case "\\get_lock_mode", "get_lock_mode":
// Truthful: OpsLog never locks the dial against its own clients.
return "0\n", false
case "\\set_lock_mode", "set_lock_mode":
// Accepted and ignored, like set_vfo below: there is no lock to set, and
// failing here would abort a client's whole transmit sequence over a
// setting that has no effect either way.
return rprt(0), false
case "\\stop_morse", "stop_morse":
// Nothing is queued here — CW over CAT is keyed by the rig's own keyer
// through the backend, not buffered in this server. "Stopped" is therefore
// accurate rather than polite.
return rprt(0), false
case "q", "Q", "\\quit":
return "", true
case "f", "\\get_freq":
return fmt.Sprintf("%d\n", s.rig.Freq()), false
case "F", "\\set_freq":
if len(args) < 1 {
return rprt(-1), false
}
hz, err := parseFreq(args[0])
if err != nil {
// Logged with the RAW line: a client that phrases a command in a
// dialect we don't accept shows only "Invalid parameter" on its side,
// which says nothing about what it actually sent.
s.log("rigctld: cannot read a frequency from %q — client dialect not handled", line)
return rprt(-1), false
}
if err := s.rig.SetFreq(hz); err != nil {
s.log("rigctld: set_freq %d failed: %v", hz, err)
return rprt(-9), false
}
return rprt(0), false
case "m", "\\get_mode":
// Passband width is required by the protocol. We do not read the rig's
// filter, and a made-up number is harmless here: clients use it to display
// a bandwidth, never to decide anything.
return fmt.Sprintf("%s\n%d\n", adifToHamlib(s.rig.Mode()), passbandFor(s.rig.Mode())), false
case "M", "\\set_mode":
if len(args) < 1 {
return rprt(-1), false
}
if err := s.rig.SetMode(hamlibToADIF(args[0])); err != nil {
s.log("rigctld: set_mode %q failed: %v", args[0], err)
return rprt(-9), false
}
return rprt(0), false
case "t", "\\get_ptt":
// Echo the last commanded PTT state. WSJT-X/JTDX poll this WHILE
// transmitting to confirm the rig is keyed; answering a blanket "0" (RX)
// made them decide PTT had failed and abort the over after ~1-2 s.
if s.ptt.Load() {
return "1\n", false
}
return "0\n", false
case "T", "\\set_ptt":
if len(args) < 1 {
return rprt(-1), false
}
on := args[0] != "0"
// Only touch the radio on a CHANGE.
//
// A client is free to restate PTT as often as it likes, and one does:
// Nexus sends set_ptt 0 about sixteen times a second, so the Flex was
// getting "xmit 0" every 60 ms forever. Worse than wasteful — its own
// "xmit 1" landed between two of them and was overwritten in the same
// millisecond, so the radio never stayed keyed and the operator saw a
// transmit request that simply did nothing.
//
// Repeating a state is not a request to change it. The first call always
// goes through, since we cannot know how the radio was left.
if s.pttKnown.Load() && s.ptt.Load() == on {
return rprt(0), false
}
if err := s.rig.SetPTT(on); err != nil {
s.log("rigctld: set_ptt %v failed: %v", on, err)
return rprt(-9), false
}
s.ptt.Store(on)
s.pttKnown.Store(true)
s.log("rigctld: PTT %s", map[bool]string{true: "ON", false: "off"}[on])
return rprt(0), false
case "v", "\\get_vfo":
return "VFOA\n", false
case "V", "\\set_vfo":
// Accepted and ignored: OpsLog follows the rig's own VFO selection, and
// answering an error here makes WSJT-X abandon the connection entirely.
return rprt(0), false
case "s", "\\get_split_vfo":
on, _ := s.rig.Split()
n := 0
if on {
n = 1
}
return fmt.Sprintf("%d\nVFOB\n", n), false
case "S", "\\set_split_vfo":
// "S <0|1> <VFO>". The VFO argument is ignored: which dial transmits is the
// rig's own business, and every backend here puts it on the second one.
//
// This used to answer RPRT 0 and do NOTHING. WSJT-X in "Split Operating:
// Rig" sends this and set_split_freq, believed both, and transmitted on the
// RECEIVE frequency — on a pileup, straight onto the DX, while the software
// showed exactly what the operator had asked for. A lie that leaves no
// trace anywhere is the worst kind of bug, so it now works or says so.
if len(args) < 1 {
return rprt(-1), false
}
if args[0] != "0" {
// Arming needs a frequency, and WSJT-X sends set_split_freq AFTER this.
// Remember the request and let that command do the work: alone, this
// would arm split on whatever the transmit VFO happens to hold.
s.splitWanted.Store(true)
return rprt(0), false
}
s.splitWanted.Store(false)
if err := s.rig.SetSplit(false, 0); err != nil {
s.log("rigctld: split off failed: %v", err)
return rprt(-9), false
}
s.log("rigctld: split off")
return rprt(0), false
case "i", "\\get_split_freq":
_, tx := s.rig.Split()
if tx <= 0 {
tx = s.rig.Freq()
}
return fmt.Sprintf("%d\n", tx), false
case "I", "\\set_split_freq":
if len(args) < 1 {
return rprt(-1), false
}
// Hamlib sends a float ("14075300.000000"), so parse as one.
hz, err := strconv.ParseFloat(args[0], 64)
if err != nil || hz <= 0 {
return rprt(-1), false
}
if err := s.rig.SetSplit(true, int64(hz)); err != nil {
s.log("rigctld: split TX %.0f Hz failed: %v", hz, err)
return rprt(-9), false
}
s.splitWanted.Store(true)
s.log("rigctld: split ON, TX %.0f Hz", hz)
return rprt(0), false
default:
// A frame ending in ';' is not a rigctl command at all — it is raw rig
// dialect (Kenwood/Elecraft/Yaesu), which means the client is configured
// with a RIG MODEL pointing at this port instead of "Hamlib NET rigctl".
//
// Worth naming, because the symptom hides the cause completely: we answer
// RPRT -11 like any unknown command, but that reply has no ';' to terminate
// on, so the client's parser waits and then reports "reply incomplete, got
// nothing". The operator sees a timeout and concludes the CAT share is
// broken, when it is a one-line setting in the other program.
if strings.HasSuffix(line, ";") && !strings.Contains(line, " ") {
s.log("rigctld: %q is a raw rig command, not rigctl — the client is set to a RIG MODEL; "+
"it must be set to \"Hamlib NET rigctl\" (rig 2) at this address", line)
return rprt(-11), false
}
// RPRT -11 is "command not implemented". Answering something is essential:
// a client waiting on a silent socket hangs rather than degrading.
s.log("rigctld: unimplemented command %q", line)
return rprt(-11), false
}
}
func rprt(code int) string { return fmt.Sprintf("RPRT %d\n", code) }
// stripVFOArg drops a leading VFO name from a command's arguments.
//
// Hamlib has two dialects. In the plain one a client sends "F 14074000"; in VFO
// mode it names the target first — "F VFOA 14074000". MSHV uses the first and
// worked immediately; JTDX uses the second, so the frequency landed in the
// argument slot where a VFO was expected, the parse failed, and JTDX showed
// "Hamlib error: Invalid parameter while setting frequency" (our RPRT -1).
//
// Accepting both costs nothing here: OpsLog follows the rig's own VFO
// selection, so the name carries no information we act on — dropping it is not
// losing anything, and refusing it locks out a whole family of clients.
func stripVFOArg(args []string) []string {
if len(args) == 0 {
return args
}
switch strings.ToUpper(args[0]) {
case "VFOA", "VFOB", "VFOC", "VFO", "CURRVFO", "CURR", "MAIN", "SUB", "MEM", "A", "B":
return args[1:]
}
return args
}
// parseFreq accepts both the integer Hz and the "14074000.000000" form clients
// send interchangeably.
func parseFreq(s string) (int64, error) {
s = strings.TrimSpace(s)
if i := strings.IndexByte(s, '.'); i >= 0 {
s = s[:i]
}
hz, err := strconv.ParseInt(s, 10, 64)
if err != nil || hz <= 0 {
return 0, fmt.Errorf("rigctld: bad frequency %q", s)
}
return hz, nil
}
// adifToHamlib maps our mode vocabulary to Hamlib's. Every digital sub-mode
// becomes PKTUSB: that is what a client expects to see when the rig is in DATA,
// and it is what WSJT-X sets when it takes control.
func adifToHamlib(mode string) string {
switch strings.ToUpper(strings.TrimSpace(mode)) {
case "SSB", "USB":
return "USB"
case "LSB":
return "LSB"
case "CW":
return "CW"
case "AM":
return "AM"
case "FM":
return "FM"
case "RTTY":
return "RTTY"
case "":
return "USB"
default:
return "PKTUSB"
}
}
// hamlibToADIF is the reverse. PKTUSB/PKTLSB/DATA become "DATA": the CAT backend
// then applies the operator's configured digital mode, so a client switching the
// rig to data does not silently relabel their QSOs as FT8 when they run JS8.
func hamlibToADIF(mode string) string {
switch strings.ToUpper(strings.TrimSpace(mode)) {
case "USB":
return "USB"
case "LSB":
return "LSB"
case "CW", "CWR":
return "CW"
case "AM":
return "AM"
case "FM", "FMN", "WFM":
return "FM"
case "RTTY", "RTTYR":
return "RTTY"
case "PKTUSB", "PKTLSB", "PKTFM", "DATA", "DIGU", "DIGL":
return "DATA"
default:
return strings.ToUpper(strings.TrimSpace(mode))
}
}
func passbandFor(mode string) int {
switch adifToHamlib(mode) {
case "CW":
return 500
case "RTTY", "PKTUSB":
return 3000
case "AM":
return 6000
case "FM":
return 15000
default:
return 2400
}
}
// dumpState is the capability block Hamlib clients read once at connect. WSJT-X
// refuses to go further without it, and parses it positionally — the field
// ORDER is the contract, so this is kept as one literal rather than assembled.
//
// It declares protocol version 0, a generic rig, and one 150 kHz1500 MHz range
// with the common modes. The numbers are deliberately permissive: they say what
// a client may ASK for, and OpsLog's backend refuses anything the radio cannot
// really do.
const dumpState = `0
1
2
150000.000000 1500000000.000000 0x1ff -1 -1 0x10000003 0x3
0 0 0 0 0 0 0
150000.000000 1500000000.000000 0x1ff -1 -1 0x10000003 0x3
0 0 0 0 0 0 0
0 0
0 0
0x1ff 1
0x1ff 0
0 0
0x1e 2400
0x2 500
0x1 8000
0x1 2400
0x20 15000
0x20 8000
0x40 230000
0 0
9990
9990
10000
0
10
10 20 30
0x3effffff
0x3effffff
0x7fffffff
0x7fffffff
0x7fffffff
0x7fffffff
`
// dialTimeout is only used by tests, kept here so the value is one place.