fix(elecraft): the K3 power meter converts to real watts
...
The operator measured the whole table: 10 W showed 83, 12 W showed 100, 13 W
showed 8 — the bargraph is relative to a meter RANGE that flips at 12 W
(0-12 QRP, 0-120 above). A bar percentage was never watts; with the PC
setting choosing the range, it converts, and the console prints the watts
beside the bar.