rouggy 15fdbce22a fix: WinKeyer 2 sent the dit/dah ratio to the key-compensation command
The byte trace from a real WK2 settled in one line what no amount of reading
could: "TX 11 32". Command 0x11 is SET KEY COMPENSATION in milliseconds, not the
dit/dah ratio — that is 0x17. So a neutral ratio of 50 asked for 50 ms of extra
key-down on EVERY element. At 25 wpm a dit is 48 ms, so elements more than
doubled and ran into each other: the reported "it sends one element, then a long
pause".

The ratio now goes out as 0x17, and the compensation is explicitly set to 0 —
merely stopping the wrong command would leave an affected keyer misbehaving,
since it keeps the value in EEPROM until something writes over it.

The init sequence is now built by a separate function so the BYTES are testable,
and a test pins each command number. These numbers are the contract with the
hardware, and a wrong one produces a fault that cannot be diagnosed from the UI
at all — this one cost the operator weeks and needed a trace to find.

This is why the fix waited for the trace rather than being guessed: the plausible
guesses (mode register, sidetone, WK1-vs-WK2 differences) were all wrong, and any
of them shipped blind would have broken the keyers that work today.
2026-07-29 14:53:18 +02:00

72 lines
2.4 KiB
Go

package winkeyer
import "testing"
// The init sequence sent to a K1EL keyer, byte for byte.
//
// This exists because of a bug that no amount of reading caught and that a
// byte-level trace from a real WK2 settled in one line: the dit/dah ratio was
// sent as command 0x11, which is SET KEY COMPENSATION in milliseconds. A
// neutral ratio of 50 therefore asked for 50 ms of extra key-down on every
// element — at 25 wpm a dit is 48 ms — so elements more than doubled and ran
// into each other. The operator saw "one element, then it stalls".
//
// The command NUMBERS are the contract with the hardware. A test on the values
// is the only thing standing between a typo here and a keyer that misbehaves in
// a way nobody can debug from the UI.
func TestApplyConfigCommands(t *testing.T) {
cmds := configCommands(Config{
WPM: 25, Weight: 50, Ratio: 50, LeadInMs: 0, TailMs: 0, Sidetone: 0,
})
// Every command that must be present, with the value it must carry.
want := map[byte][]byte{
0x02: {25}, // speed
0x03: {50}, // weighting — 50 is neutral, and this one WAS right
0x17: {50}, // dit/dah ratio — the corrected opcode
0x11: {0x00}, // key compensation explicitly cleared
}
seen := map[byte][]byte{}
for _, c := range cmds {
if len(c) < 2 {
t.Fatalf("command %X has no argument", c)
}
seen[c[0]] = c[1:]
}
for op, args := range want {
got, ok := seen[op]
if !ok {
t.Errorf("command 0x%02X is not sent at all", op)
continue
}
if len(got) != len(args) || (len(args) > 0 && got[0] != args[0]) {
t.Errorf("command 0x%02X carries % X, want % X", op, got, args)
}
}
// The ratio must NEVER go out as 0x11 again: that is the whole bug.
if v, ok := seen[0x11]; ok && len(v) > 0 && v[0] != 0 {
t.Errorf("0x11 (key compensation) carries %d — it must be 0, not the ratio", v[0])
}
}
// A keyer left with compensation by an earlier version keeps it in EEPROM, so
// the fix has to CLEAR it rather than merely stop setting it.
func TestKeyCompensationIsCleared(t *testing.T) {
for _, ratio := range []int{33, 50, 66} {
cmds := configCommands(Config{WPM: 20, Weight: 50, Ratio: ratio})
found := false
for _, c := range cmds {
if c[0] == 0x11 {
found = true
if c[1] != 0 {
t.Errorf("ratio %d: key compensation sent as %d, want 0", ratio, c[1])
}
}
}
if !found {