rouggy e6b8a17772 fix: a rig reporting LSB/USB left the mode selector empty
From a Kenwood trace: IF answered mode digit 1 on 7.160 MHz, the backend read
LSB correctly, and the entry form showed no mode at all while the frequency
tracked perfectly.

Nothing was wrong in the backend. Radios report the SIDEBAND, and the station's
mode list holds SSB — so the value pushed into the selector was not in its own
list of options and nothing could match. Yaesu and Icom report the same way, so
this was never Kenwood-specific; it only surfaced there.

Normalising at the point where a rig-reported mode enters the form fixes every
backend at once, rather than editing three mode tables and the next backend
someone writes.

It is also the ADIF-correct direction, which matters more than the selector:
LSB and USB are SUBMODEs in ADIF, not modes. MODE=LSB is not a valid value and
is what would have gone to LoTW and eQSL.

An operator who has deliberately put LSB or USB in their own mode list keeps
them — the list is their statement of what they log, not ours.