Files
OpsLog/internal/cat
rouggy fc080f3719 fix(icom): kill the leftover waveform in both command forms, and say so
The blind kill at connect still left a real 7760 streaming — the selector
byte differs by model, and the result was discarded so a quiet failure looked
like a cure. Both forms go out now (a NAK costs one frame) and the outcomes
are logged. The power table also gains its third measured anchor: a real
200 W reads full deflection, so raw 213 is 200 W — not the printed face's
250.
2026-08-30 02:43:43 +02:00
..
2026-08-21 23:28:55 +02:00
2026-07-26 16:57:19 +02:00