// Package steppir controls a SteppIR SDA-100 / SDA-2000 antenna controller over
// its "Transceiver Interface" serial protocol, reached either directly on a COM
// port or over TCP through an RS232↔Ethernet bridge (the same way OpsLog talks to
// an Ultrabeam). The client mirrors the ultrabeam.Client surface so the app can
// drive either behind one interface.
//
// Protocol (cross-checked against the SteppIR "Transceiver Interface Operation"
// note, the we7u/steppir library, and the la1k.no write-up — three independent
// sources that agree, which is what makes the byte layout trustworthy):
//
// SET : "@A" <freq> 00 <dir> <cmd> 00 0x0D (11 bytes)
// <freq> = int32 big-endian of (Hz / 10)
// <dir> = 0x00 normal · 0x40 180° · 0x80 bidirectional · 0x20 3/4-wave
// <cmd> = '1' set freq+dir · 'R' autotrack ON · 'U' autotrack OFF
// 'S' home/retract · 'V' calibrate
// STATUS: "?A" 0x0D → 11 bytes back:
// [2:6] int32 big-endian frequency (× 10 = Hz)
// [6] active-motor bitmask (0xFF = command received / setup)
// [7] & 0xE0 direction
//
// Timing: the controller needs ≥100 ms between commands and dislikes status
// polls faster than ~10/s. The poll loop runs at 2 s, well inside that.
package steppir
import (
"bytes"
"encoding/binary"
"errors"
"fmt"
"io"
"log"
"net"
"sync"
"time"
"go.bug.st/serial"
)
// errBadFrame marks a reply that isn't a well-formed status frame. It means
// "ignore this poll", not "the link is down".
var errBadFrame = errors.New("steppir: malformed status frame")
// Direction values, matching the app-wide convention (also used by Ultrabeam):
// 0 normal, 1 reverse (180°), 2 bidirectional.
const (
DirNormal = 0
Dir180 = 1
DirBi = 2
)
// SteppIR direction bytes on the wire.
const (
wireNormal = 0x00
wire180 = 0x40
wireBi = 0x80
)
// pendingDirTTL is how long a commanded direction is trusted over the
// controller's own report. The elements physically re-tune to swap director and
// reflector, and the SDA only reports the new pattern once it starts that move,
// so a few seconds is not enough — 4 s (the original value) had the UI snapping
// back to "normal" while the antenna was on its way to 180°. Long enough to
// cover a real move, short enough that a command the controller never received
// self-corrects instead of lying forever.
const pendingDirTTL = 45 * time.Second
// Transport says how to reach the controller.
type Transport struct {
Mode string // "tcp" | "serial"
Host string // tcp
Port int // tcp
COM string // serial device (COM3, /dev/ttyUSB0)
Baud int // serial baud (controller default 9600; 1200-19200 valid)
}
// Status is the antenna state, in the same shape the app reads from the
// Ultrabeam so the two are interchangeable at the UI.
type Status struct {
Connected bool `json:"connected"`
Frequency int `json:"frequency"` // kHz
Band int `json:"band"` // 0 (SteppIR does not report a band index)
Direction int `json:"direction"` // 0 normal, 1 180°, 2 bidirectional
MotorsMoving int `json:"motors_moving"`
}
type Client struct {
tr Transport
connMu sync.Mutex
conn io.ReadWriteCloser
// ioMu serialises EVERY exchange on the shared connection — a status query
// (write "?A" then read 11 bytes) and a command write must never interleave,
// or their bytes mix on the wire and both frames are corrupted. The status
// poll runs on one goroutine, tuning on another, so this is essential.
ioMu sync.Mutex
statusMu sync.RWMutex
lastStatus *Status
lastSetKHz int
// lastRaw holds the previous raw status frame so we only log a status line
// when the controller's reply actually changes — enough to diagnose a stuck
// "motors moving" read (which drives the app's TX-inhibit interlock) without
// spamming the log every 2 s poll.
lastRaw []byte
// A just-commanded direction is held until the controller's poll reports it —
// the motors take a second or two, and a stale poll would otherwise snap the
// UI back. Same trick as the Ultrabeam client.
//
// The hold is deliberately long (pendingDirTTL). It is not just a UI nicety:
// the follow loop re-tunes with the direction it reads back from this status,
// so a single stale poll reading "normal" would make OpsLog command the
// antenna out of 180° all by itself.
pendingDir int
pendingDirAt time.Time
pendingDirSet bool
stopChan chan struct{}
running bool
}
func New(tr Transport) *Client {
if tr.Baud <= 0 {
tr.Baud = 9600
}
return &Client{tr: tr, stopChan: make(chan struct{})}
}
func (c *Client) Start() error {
c.running = true
go c.pollLoop()
return nil
}
func (c *Client) Stop() {
if !c.running {
return
}
c.running = false
close(c.stopChan)
c.connMu.Lock()
if c.conn != nil {
c.conn.Close()
c.conn = nil
}
c.connMu.Unlock()
}
// LastSetKHz returns the frequency last commanded, or 0.
func (c *Client) LastSetKHz() int {
c.statusMu.RLock()
defer c.statusMu.RUnlock()
return c.lastSetKHz
}
func (c *Client) GetStatus() (*Status, error) {
c.statusMu.RLock()
defer c.statusMu.RUnlock()
if c.lastStatus == nil {
return &Status{Connected: false}, nil
}
return c.lastStatus, nil
}
// open dials the transport. Callers hold connMu.
func (c *Client) open() (io.ReadWriteCloser, error) {
switch c.tr.Mode {
case "serial":
if c.tr.COM == "" {
return nil, fmt.Errorf("steppir: no serial port configured")
}
p, err := serial.Open(c.tr.COM, &serial.Mode{BaudRate: c.tr.Baud})
if err != nil {
return nil, err
}
// A finite read timeout so a silent controller doesn't wedge the poll loop.
_ = p.SetReadTimeout(2 * time.Second)
return p, nil
default: // tcp
if c.tr.Host == "" {
return nil, fmt.Errorf("steppir: no host configured")
}
d := net.Dialer{Timeout: 5 * time.Second}
return d.Dial("tcp", net.JoinHostPort(c.tr.Host, fmt.Sprintf("%d", c.tr.Port)))
}
}
func (c *Client) pollLoop() {
ticker := time.NewTicker(2 * time.Second)
defer ticker.Stop()
for {
select {
case <-c.stopChan:
return
case <-ticker.C:
c.connMu.Lock()
if c.conn == nil {
conn, err := c.open()
if err != nil {
c.connMu.Unlock()
c.setDisconnected()
continue
}
c.conn = conn
}
c.connMu.Unlock()
st, err := c.queryStatus()
if errors.Is(err, errBadFrame) {
// Framing glitch, not a dead link: skip this tick and keep the
// previous status. Dropping the connection here would blink the
// UI to "disconnected" over one garbled reply.
continue
}
if err != nil {
log.Printf("steppir: status query failed, reconnecting: %v", err)
c.closeConn()
c.setDisconnected()
continue
}
st.Connected = true
c.statusMu.Lock()
c.applyPendingDir(st)
c.lastStatus = st
c.statusMu.Unlock()
}
}
}
// applyPendingDir replaces a freshly polled direction with the one the operator
// last commanded, until the controller confirms it (or the hold expires). The
// caller holds statusMu.
func (c *Client) applyPendingDir(st *Status) {
if !c.pendingDirSet {
return
}
switch {
case st.Direction == c.pendingDir:
c.pendingDirSet = false // confirmed — trust the controller's reports again
case time.Since(c.pendingDirAt) > pendingDirTTL:
c.pendingDirSet = false
log.Printf("steppir: controller never confirmed direction %d (still reports %d) — dropping the hold",
c.pendingDir, st.Direction)
default:
st.Direction = c.pendingDir
}
}
func (c *Client) setDisconnected() {
c.statusMu.Lock()
c.lastStatus = &Status{Connected: false}
c.statusMu.Unlock()
}
func (c *Client) closeConn() {
c.connMu.Lock()
if c.conn != nil {
c.conn.Close()
c.conn = nil
}
c.connMu.Unlock()
}
// setDeadline applies a read/write deadline on TCP; serial uses its own timeout.
func setDeadline(conn io.ReadWriteCloser, d time.Duration) {
if nc, ok := conn.(net.Conn); ok {
_ = nc.SetDeadline(time.Now().Add(d))
}
}
// setReadTimeout bounds a single read on either transport, so a drain can tell
// "nothing more queued" from "still arriving" without blocking.
func setReadTimeout(conn io.ReadWriteCloser, d time.Duration) {
switch t := conn.(type) {
case net.Conn:
_ = t.SetReadDeadline(time.Now().Add(d))
case serial.Port:
_ = t.SetReadTimeout(d)
}
}
// restoreTimeouts puts the normal exchange timeouts back after a drain shortened
// them.
func restoreTimeouts(conn io.ReadWriteCloser) {
setDeadline(conn, 3*time.Second) // TCP: read + write
setReadTimeout(conn, 2*time.Second)
}
// drain throws away everything already sitting in the input buffer and returns
// how many bytes it discarded.
//
// This is the fix for the antenna's state appearing tens of seconds out of date.
// The SDA controller does not only answer "?A" — it also pushes status frames on
// its own (front-panel changes, autotrack moves, each command it processes). We
// consume exactly one frame per poll, so every unsolicited frame adds one to a
// backlog that only ever grows: reading 11 bytes then returns a frame from
// minutes ago. The field log showed it plainly — two consecutive polls 4 s apart
// reporting 28280 kHz then 14200 kHz, a frequency last used hours earlier, and a
// 180° command not showing up in the status for ~40 s (long after the UI had
// given up waiting and snapped the button back to "normal"). Emptying the buffer
// immediately before each query means the frame we then read is the answer to
// THIS query.
func drain(conn io.ReadWriteCloser) int {
buf := make([]byte, 512)
total := 0
// Bounded so a controller that streams continuously can't hold the poll
// goroutine here forever. 32 × 512 B is ~1500 frames — far more backlog than
// any real link builds up, and it only costs one 30 ms timeout when the
// buffer is already empty (reads return immediately while data is queued).
for i := 0; i < 32; i++ {
setReadTimeout(conn, 30*time.Millisecond)
n, err := conn.Read(buf)
total += n
if err != nil || n == 0 { // timeout / nothing left
break
}
}
return total
}
func (c *Client) queryStatus() (*Status, error) {
c.connMu.Lock()
conn := c.conn
c.connMu.Unlock()
if conn == nil {
return nil, fmt.Errorf("steppir: not connected")
}
c.ioMu.Lock()
defer c.ioMu.Unlock()
// Discard any frame the controller pushed on its own since the last poll, so
// what we read below is this query's answer and not a stale backlog entry.
if n := drain(conn); n > 0 {
log.Printf("steppir: discarded %d stale byte(s) queued by the controller before polling", n)
}
restoreTimeouts(conn)
if _, err := conn.Write([]byte("?A\r")); err != nil {
return nil, fmt.Errorf("write status cmd: %w", err)
}
buf := make([]byte, 11)
if _, err := io.ReadFull(conn, buf); err != nil {
return nil, fmt.Errorf("read status: %w", err)
}
// Reject anything that isn't a framed reply rather than decoding garbage into
// a frequency and a direction the app would then act on.
if buf[0] != '@' || buf[1] != 'A' || buf[10] != 0x0D {
log.Printf("steppir: ignoring malformed status frame % X", buf)
drain(conn) // resync: drop the rest of whatever we landed mid-way through
restoreTimeouts(conn)
return nil, errBadFrame
}
st, err := parseStatus(buf)
// Log the raw frame + decode whenever it changes. The motor byte (buf[6]) is
// what decides st.MotorsMoving, and that in turn drives the app's "block TX
// while moving" interlock — so if a controller (e.g. with its INHIBIT engaged)
// reports a byte we misread as perpetual motion, this line makes it visible.
if err == nil && !bytes.Equal(buf, c.lastRaw) {
c.lastRaw = append(c.lastRaw[:0], buf...)
log.Printf("steppir: status ← % X (freq=%d kHz dir=%d moving=%d motorByte=0x%02X dirByte=0x%02X)",
buf, st.Frequency, st.Direction, st.MotorsMoving, buf[6], buf[7])
}
return st, err
}
// parseStatus decodes an 11-byte status frame.
func parseStatus(b []byte) (*Status, error) {
if len(b) < 11 {
return nil, fmt.Errorf("steppir: short status frame (%d bytes)", len(b))
}
freqHz := int(int32(binary.BigEndian.Uint32(b[2:6]))) * 10
active := b[6]
dir := decodeDir(b[7])
// active-motors byte: one bit per element that is currently moving.
// 0x04 driver · 0x08 DIR1 · 0x10 reflector · 0x20 DIR2 (mask 0x3C)
// Bit 0 (0x01) is documented as always set — not a motor. 0xFF means the
// controller just received a command, not motion. So "moving" is precisely
// "any real motor bit set", ignoring the always-on bit and the ack value.
const motorBits = 0x3C
moving := 0
if active != 0xFF && active&motorBits != 0 {
moving = 1
}
return &Status{Frequency: freqHz / 1000, Direction: dir, MotorsMoving: moving}, nil
}
func decodeDir(b byte) int {
switch b & 0xE0 {
case wireBi:
return DirBi
case wire180:
return Dir180
default:
return DirNormal
}
}
func dirWireByte(dir int) byte {
switch dir {
case Dir180:
return wire180
case DirBi:
return wireBi
default:
return wireNormal
}
}
// buildSet frames a SET command: "@A" <freq be32 of Hz/10> 00 <dir> <cmd> 00 CR.
func buildSet(freqHz int, dir int, cmd byte) []byte {
var f [4]byte
binary.BigEndian.PutUint32(f[:], uint32(freqHz/10))
out := make([]byte, 0, 11)
out = append(out, '@', 'A')
out = append(out, f[:]...)
out = append(out, 0x00, dirWireByte(dir), cmd, 0x00, 0x0D)
return out
}
func (c *Client) writeCmd(pkt []byte) error {
c.connMu.Lock()
conn := c.conn
c.connMu.Unlock()
if conn == nil {
return fmt.Errorf("steppir: not connected")
}
c.ioMu.Lock()
defer c.ioMu.Unlock()
log.Printf("steppir: → % X", pkt)
setDeadline(conn, 3*time.Second)
if _, err := conn.Write(pkt); err != nil {
c.closeConn()
return err
}
// The controller needs breathing room between commands.
time.Sleep(120 * time.Millisecond)
return nil
}
// SetFrequency tunes the elements to freqKhz with the given direction.
//
// AUTOTRACK is (re-)enabled first, EVERY time: the controller ignores frequency
// sets unless it is in AUTOTRACK mode ("when not in AUTOTRACK only CALIBRATE and
// RETRACT work"), and it can be out of AUTOTRACK at power-on, after a Home, or if
// switched off on the front panel. Sending the 'R' command each tune is cheap and
// makes tuning work regardless of the controller's current mode — which is what
// was silently failing before.
func (c *Client) SetFrequency(freqKhz int, direction int) error {
if err := c.writeCmd(buildSet(freqKhz*1000, direction, 'R')); err != nil { // AUTOTRACK ON
return err
}
if err := c.writeCmd(buildSet(freqKhz*1000, direction, '1')); err != nil { // set freq + dir
return err
}
c.statusMu.Lock()
c.lastSetKHz = freqKhz
c.pendingDir, c.pendingDirAt, c.pendingDirSet = direction, time.Now(), true
c.statusMu.Unlock()
return nil
}
// SetDirection changes the pattern. SteppIR has no standalone direction command —
// it is a SET with the current frequency and the new direction byte.
func (c *Client) SetDirection(direction int) error {
khz := c.LastSetKHz()
if khz <= 0 {
if st, _ := c.GetStatus(); st != nil {
khz = st.Frequency
}
}
if khz <= 0 {
return fmt.Errorf("steppir: no frequency known yet — cannot set direction")
}
return c.SetFrequency(khz, direction)
}
// Retract homes the elements into the hubs (storage). This drops the controller
// out of AUTOTRACK, but that is handled transparently: the next SetFrequency
// re-issues AUTOTRACK ON before tuning.
func (c *Client) Retract() error {
// A valid frequency must accompany the command; reuse the last one.
khz := c.LastSetKHz()
if khz <= 0 {
if st, _ := c.GetStatus(); st != nil && st.Frequency > 0 {
khz = st.Frequency
} else {
khz = 14000 // any in-range value; the controller just homes
}
}
return c.writeCmd(buildSet(khz*1000, DirNormal, 'S'))
}