chore: release v0.19.2
This commit is contained in:
@@ -0,0 +1,55 @@
|
||||
# Remote Icom over the Internet
|
||||
|
||||
OpsLog speaks the Icom radio's **built-in network protocol** directly, so it
|
||||
**replaces both the Icom Remote Utility and RS-BA1**. Radios with a LAN server —
|
||||
**IC-7610, IC-9700, IC-705, IC-7760, IC-905** — can be operated over the
|
||||
LAN/internet with the full [[Icom]] console.
|
||||
|
||||
> The **IC-9100 has no LAN server** — it is USB-only.
|
||||
|
||||
## On the radio (one-time)
|
||||
|
||||
In the radio's **Network** menu:
|
||||
|
||||
1. Enable the network / *Remote settings*.
|
||||
2. Set a **Network User1** name and password.
|
||||
3. Note the radio's **IP address** and its **CI-V address**.
|
||||
4. Make sure the Icom **Remote Utility is closed** on every PC — OpsLog binds the
|
||||
same local UDP ports, so they can't both run.
|
||||
|
||||
## In OpsLog
|
||||
|
||||
Settings → CAT → backend **Icom CI-V (network / remote)**:
|
||||
|
||||
- **Host** — the radio's IP or hostname.
|
||||
- **User / Password** — the Network User1 credentials.
|
||||
- **Rig model / CI-V address** — pick the model.
|
||||
|
||||
Save. OpsLog logs in, obtains a session **token** (auto-renewed so control never
|
||||
drops after ~2 minutes), opens the **CI-V tunnel**, and the whole console works
|
||||
over the net — freq / mode / DSP / TX / RIT / CW / scope.
|
||||
|
||||
## How it stays solid
|
||||
|
||||
- **Token renewal** every ~45 s keeps the session alive.
|
||||
- **Receive-side retransmit**: under the heavy panadapter stream, lost UDP
|
||||
packets are re-requested, so the link doesn't drop when the scope is on.
|
||||
- **Standby-tolerant**: the radio's server answers pings even when the radio is
|
||||
off, so the session doesn't flap — the console + power ON button stay reachable.
|
||||
- **Manual power** ON / OFF (the app never wakes the rig on connect).
|
||||
|
||||
## Audio
|
||||
|
||||
Network **audio** is a work in progress. For now, use the radio in **USB + a
|
||||
voice link** (e.g. Mumble) alongside the network CAT, or run OpsLog on the
|
||||
station PC via remote desktop. See [[Audio and Keyers]] for the USB-monitor
|
||||
option.
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
- **"Login rejected"** → wrong Network User1 name/password.
|
||||
- **Can't bind local port / dial fails** → the Icom **Remote Utility** is still
|
||||
running; close it.
|
||||
- **Link drops when the scope turns on** → should be fixed by receive-side
|
||||
retransmit; if it persists, check the log (`icom net:` lines) and network
|
||||
quality. See [[Troubleshooting]].
|
||||
Reference in New Issue
Block a user