My mistake yesterday: the new confirmation columns went into uploadStatusCols —
the QSL Manager's FILTER whitelist — instead of bulkEditableCols. The dialog
listed QRZ.com received status and the ten dates, and the repository refused
them at Apply, after the operator had selected 54 QSOs.
Moved to the right map. And two fields have been broken this way since long
before: State and County were offered under "Contacted station" (whose IOTA /
POTA / SOTA / SIG siblings are all allowed) but were missing from the whitelist,
so choosing one always failed. Added — they are exactly what an import loses and
what a whole run shares.
The real fix is the test. Two lists in two languages had to agree by hand and
nothing checked it, so the failure only ever surfaced as an error message at the
last click. The new tests read the ACTUAL field ids out of BulkEditModal.tsx and
FilterBuilder.tsx and assert the repository accepts every one — a field added to
the UI alone now fails the build instead of the operator.
They arrive many times a second and were dumped every 5 s, drowning the rest of
the log. They only ever existed to confirm the meter NAMES during development,
which the subscription line already does — and that one is now a single summary
instead of one line per meter, a Flex announcing dozens of them at each connect.
OmniRig reports the VFO pair (AA/AB/BA/BB) on the whole Yaesu range and never
the single-letter form. Only the latter was honoured, so every rig in that
family stayed pinned to VFO A: pressing SUB moved the radio but not OpsLog,
and a QSO worked on SUB was logged on the main VFO's frequency. The first
letter of the pair is the VFO being listened on — Log4OM reads it and gets the
right frequency on the same rigs, which is what showed the data was there.
The enum now wins over the Yaesu Freq==FreqB inference, which is only a
fallback for a rig file that names no VFO at all (the stock FTDX10 one answers
neither VS; nor FR; usably — verified on the air).
Split: the ON flag is still latched to survive a rig file that flips it on its
own, but the latch is now ARMED only after 8 flips in 30 s. A first cut at
3-in-15s was armed by the operator toggling split while testing, imposing the
6 s clearing delay on a radio that did not need it; a misreading file flips a
dozen times in that window untouched, so the two cases separate cleanly.
Distance (km) column added to Recent QSOs and Worked before (shared catalog).
Computed from the QSO's OWN my_grid/my_lat/lon first, falling back to the
current profile's locator: a log spans years and portable outings, so the
station a QSO was made from is not necessarily today's.
Locator: a precise QRZ/HamQTH grid is no longer overwritten by the cty.dat
entity centroid. The lookup runs several times per QSO and the provider gets
2 s; a slow second answer fell back to cty.dat and downgraded JN05JG to JN16
while name and QTH survived (they are only written when non-empty).
The OmniRig diagnostic line now logs what OpsLog concluded, not just what
OmniRig reported. icomnet.go: gofmt alignment only.
- SCP/N+1: new internal/scp downloads the community MASTER.SCP master list and a
docked two-column widget shows, as you type a call, the known calls containing it
(Partial) and the calls one edit away (N+1) — click to fix a busted call. Opt-in
in Settings → General; top-bar toggle; queried debounced on callsign input.
- Flex: OpsLog's GUI-client detection was too loose and could bind to "SmartSDR CAT"
(or DAX) — both carry "smartsdr" in the program name — instead of the real GUI
client, making SmartSDR CAT drop and reconnect in a loop while OpsLog was open.
Now it binds only to a real SmartSDR/Maestro GUI client (e.g. a FLEX-8600M's
integrated screen) and excludes cat/dax; dropped the risky empty-program fallback.
- Telemetry: on a fresh install the callsign isn't set at launch, so the once-a-day
heartbeat recorded the machine UUID. Now it waits (~10 min) for the operator to
enter their callsign before sending, falling back to the UUID only if none appears.
The motorized-antenna follow loop keyed its deadband off the antenna's reported
frequency. A SteppIR reports an intermittent/stale status frequency (flips
between the commanded freq and its home/6 m value), so the deadband tripped on
almost every 1.5 s poll and re-issued a tune command. Each command refreshed
noteMotorMoveCommanded(), keeping motorTXInhibitLoop's recentCmd window alive, so
the Flex transmit-inhibit ("Interlock is preventing transmission") never
released — confirmed in a real log (moving=0 throughout, recentCmd was the
driver).
Follow loop now keys the deadband off the LAST COMMANDED rig frequency, only
re-tuning when the radio actually QSYs beyond the step — immune to a flaky
antenna status. Falls back to the antenna's freq only until the first command.
Also dropped SetTXInhibit's `interlock set reason=` sends: `reason` is a
read-only field on the Flex interlock object, so writing it is rejected
(cmd error 5000002D on V1.4.0.0) and did nothing; `transmit set inhibit=` is the
real mechanism and is unchanged.
Confirmed from an FT-891 CAT log: OpsLog tuned via OmniRig's SetSimplexMode,
which returned OK on every spot click but never moved the VFO (readback stayed
put), while SetMode on the same .ini worked — so the CAT link was healthy and
only the frequency write was a no-op. SetSimplexMode was chosen because Icoms
accept direct FreqA writes but don't move; Yaesu/Kenwood are the opposite.
Now, for non-Icom rigs (or if SetSimplexMode errors), also write the VFO
frequency property (FreqA/Freq) directly, which does move them. Icom keeps the
SetSimplexMode-only path so the Main/Sub VFO isn't nudged by a direct write.
The rig's 0x27 waveform frames carry the same leading main-scope selector byte
as the dual-scope IC-7610/9700 (`27 00 00 <seq> <total> …`), but the code keyed
the layout off the CI-V address and treated the 7300 as selector-less, reading
the sequence from Data[1] (always 0x00) so every frame hit the `seq == 0`
guard and was dropped — blank scope. The waveform parser now detects the
leading selector byte from the frame itself (address-independent), and the
scope config/set commands (mode, span, edges) include the selector the 7300
requires. The IC-7610/9700 path is byte-for-byte unchanged (main → idx 2, sub
frames skipped). Confirmed against a real IC-7300 CI-V capture.
SetScope(false) sent both 0x27 0x10 00 (scope DISPLAY off) and 0x27 0x11 00
(CI-V data output off), so quitting OpsLog blanked a local IC-7300's own scope
screen. Only the display-on (0x27 0x10 01) is now sent, and only on enable;
disable stops the CI-V stream alone and never touches the radio's display.
The multi-frame waveform header (USB path) read the second frequency field
as an absolute high edge, but in center mode it is a span — so high < low and
the panadapter had no valid range to map the trace onto (blank scope). It now
applies the same center+span vs low+high disambiguation the IC-7610 single-
frame path already used. FIXED mode was unaffected.
Also stamps changelog 0.20.10 with today's date.
Multi-amp: Settings->Amplifier becomes a list (amps.json, legacy single-amp keys auto-migrate to entry #1); one client per enabled amp with per-id bindings (GetAmplifiers/SaveAmplifiers/GetAmpStatuses/AmpOperate/AmpPower/AmpPowerLevel/AmpFanMode); legacy a.pgxl/a.spe/a.acom point at the first enabled amp of each family. Amp cards in FlexPanel and Station Control gain a dropdown to pick the amp; the status bar shows one clickable chip per amp. Use case: two SPEs run in parallel.
Flex v4 DSP (8000/Aurora): NRL/ANFL (lms_nr/lms_anf), NRS (speex_nr), NRF (nrf) with level sliders, RNN (rnnoise) and ANFT on/off — keys per the FlexLib slice docs; the section only shows when the radio reports these keys (dsp_v4 flag), so 6000-series panels are unchanged.
Completes the CWX type-ahead loop: with send-on-type the keyer-panel CW text
already streams each typed char to the radio's CWX buffer (which keys in order,
so you can keep typing while it sends); this adds the matching un-send. Route
wkBackspace to FlexBackspaceCW -> cwx erase N, so backspacing a mistyped char in
send-on-type removes it from the buffer before the radio keys it.
The 7610-only FreqA gate broke CAT on the 7610 when FreqA was momentarily 0.
Match DXHunter/WSJT-X: read FreqA first for all rigs, fall back to the generic
Freq (IC-9100 etc.), then FreqB. OmniRig's generic Freq maps to VFO B on the
7610, which is why keying off FreqA is correct.
OmniRig: on the IC-7610 the generic Freq property reports the wrong VFO (its
Main/Sub model confuses the stock ini), so OpsLog showed VFO B. Detect the rig
by RigType and, in simplex, read VFO A explicitly — matching Log4OM. Only the
7610 is affected; other rigs keep using the generic Freq.
Icom network: when the rig tears the session down (control/CI-V 0x05) OpsLog
only logged it and kept the half-dead link until the 6 s liveness timeout
expired. Mark the link dead on 0x05 so Alive() fails on the next poll and the
manager reconnects cleanly right away.